HM-95 Series
HITROL CO., LTD.
5
Technical Specifications Weatherproof
Ex-Proof
※
The housing is designed to avoid damage from dust or water, and if necessary, anti-
corrosion housing (EPOXY Coated) can be selected.
Model
HM-95
HM-95H
HM-95V
HM-95VH
Process Connection
100A JIS 10K RF, Others
1
''
Socket, Others
Ambient Temperature
-20
°
C
to +80
°
C
Max. Process Temp.
-40℃ to +120℃
-40℃ to +200℃
-40℃ to +350℃
-40℃ to +500℃
-40℃ to +120℃
-40℃ to +200℃
-40℃ to +350℃
-40℃ to +500℃
Max. Process Pressure
Up to 63 kg/cm
2
(900#)
Up to 105 kg/cm
2
(1,500#)
Switch Type
Micro switch, Hermetical Sealed (Opt.)
Contact Form
SPDT, DPDT
Enclosure
Weatherproof (IP65)
Material
Float
316L
Cage
Opt.
C.S, 304, 316 L, Others
Housing; Cable Entry
C.S; PF 3/4
''
(F), AL.; PF 3/4
''
(F), Others
Installation
Top
Top and Bottom, Side to Side
Model
HM-95-Ex
HM-95H-Ex
HM-95V-Ex
HM-95VH-Ex
Process Connection
100A JIS 10K RF, Others
1
''
Socket, Others
Ambient Temperature
-20
°
C
to +80
°
C
Max. Process Temp.
-40℃ to +12
0℃
-40℃ to +200℃
-40℃ to +300℃
-40℃ to +350℃
-40℃ to +120℃
-40℃ to +200℃
-40℃ to +300℃
-40℃ to +350℃
Max. Process Pressure
Up to 63 kg/cm
2
(900#)
Up to 105 kg/cm
2
(1,500#)
Switch Type
Micro switch, Hermetical Sealed (Opt.)
Contact Form
SPDT, DPDT
Enclosure
Ex-Proof (Ex d IIC T4, IP65)
Material
Float
316 L
Cage
Opt.
C.S, 304, 31 6L, Others
Housing; Cable Entry
AL.; PF 3/4
''
(F), Others
Installation
Top
Top and Bottom, Side to Side