background image

HTM-930N Series 

   

Page 

8

 / 

9

                                                   

  HITROL CO.,LTD.                               

Doc. no. : HTM-930N_IM_Eng_Rev.0 

Issued date : 2018. 01 

Safety and   
Environment

 

 
 

 

 
 
 
 
 
 
 
Marking 
 

 

 

 
 
Matters 
Regarding 
User Training   

 

 

Failure Check 
And Maintenance 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Status 

Check List 

POWER (PWR.) LED is Off 

Check wiring of POWER and check the voltages 

RELAY (RLY.) LED is Off 

Adjust the DELAY TIME (E.TIME) Dial 

SENSING (DET.) LED is off 

Adjust the SENSITIVITY (SENS.) Dial 

Status 

Check List 

POWER (PWR.) LED is Off. 

Check wiring of POWER and check the voltages 

Vibration of Sensor is weak 

Turn to adjust the vibration of sensor 

(VIBRATION (VIB.) Dial) 

Wrong wiring of Sensor Cable 

- Check and fasten the connecter to sensor 

- Check the wiring with color of cables to Controller 

Bent of Sensor 

Contact Hitrol AS team. 

■  Precautions for Using 

        - When installation to the tank, it should be proceeded using adequative tools 

        - Avoid any impact to the product 

■  Precautions for Wiring 

        -  When  wiring,  cables  should  be  wired  to  terminal  correctly  as  per  required  wiring 

method (Refer to Wiring) 

■  Disposal of the product 

        - When the product is discarded, dispose it after separation of the AMP in the housing, 

and main sensor.   

* There is no part influencing over environment, user does not require to pay attention. 

■  Product Identification Mark   

Name Plate is attached on the Housing, describing the Model of product, serial 

number, operating temperature, operating pressure and output signal. The Serial 

number is a unique manufacturing number for the identification of product.

 

Temperature  of  the  medium  in  the  tank  should  not  exceed  max.  250deg.C.  And 

also,  ambient  temperature  around  housing  should  not  be  over  -20Deg.C  ~ 

+60Deg.C. 

■  If it is detected the medium but there is no change of output signal. 

■  If it is not detected the medium and there is no vibrating of sensor. 

Содержание HLC-901LN

Страница 1: ...Issued date 2018 01 HITROL CO LTD HEAD OFFICE FACTORY R D INSTITUDE HITROL CO LTD 141 Palhakgol gil Jori eup Paju si Gyeonggi do Korea TEL 00 82 31 950 9700 FAX 00 82 31 950 9796 9799 www hitrol com INSTRUCTION MANUAL VIBRATION TYPE LEVEL SWITCH HTM 930N HLC 901N_Series ...

Страница 2: ...ication 4 SENSOR 4 COMBINATION UNIT 4 Wiring and Operating Method 5 Dimension 6 Maintenance 7 Removal Cautions 7 Precautions for Installation 7 Installation 7 Safety and Environment 8 Marking 8 Matters Regarding User Training 8 Failure Check and Maintenance 9 Quality Assurance and Warranty Service 9 Contact Headquarter Factory and R D Center 9 Table of Contents ...

Страница 3: ...edium such as solids or powder with simple structure The device can be measured the solids of low density Styrofoam and it is basically used for EPS Expandable Polyethylene Machine because it is applicable to Styrofoam which has very low density The sensor is composed of one module consisting of oscillator coil an induction coil When the medium does not contacted with the sensing probe the sensor ...

Страница 4: ...Enclosure Weather Proof IP65 Body SS400 Painting Process Connection PT 3 4 SUS304 Wetted Part SUS 316L COMBINATION UNIT Model HLC 901LN HLC 901PN HLC 901PN Installation Local Panel Inside Ambient Temperature 20 C 60 C Power Source AC 90 240V 0 25A 50 60Hz AC 24V DC 24V DC 24V AC 24V Contact Form 1 DPDT 1 SPDT Contact Rating AC 250V 5A DC 30V 5A Enclosure Weather Proof IP54 Housing Material Aluminu...

Страница 5: ...ut LED POWER PWR When power is connected the Green LED is On RELAY RLY When activate the relay the Green LED is On SENSING DET When detect the medium the Red LED is On Dial DELAY TIME D TIME When detected the medium the Delay time for relay activation can be adjusted 1 15sec SENSITIVITY SENS Adjust sensitivity of sensor VIBRATION VIB Adjust vibration of sensor Caution the wrong wiring can be affec...

Страница 6: ...HTM 930N Series Page 6 9 HITROL CO LTD Doc no HTM 930N_IM_Eng_Rev 0 Issued date 2018 01 Dimension HLC 901PN HLC 901PN HLC 901LN HTM 930N Actual product may have a tolerance slightly ...

Страница 7: ...connector for the installation In order to prevent a loosening washer should be used between the bolt and nut Gasket should be used between flanges Gasket should be selected considering of temperature of medium and pressure of the tank The Power should be connected after completed installation and wiring Below recommendation should be considered when installation It is recommend to clean and check...

Страница 8: ...nk it should be proceeded using adequative tools Avoid any impact to the product Precautions for Wiring When wiring cables should be wired to terminal correctly as per required wiring method Refer to Wiring Disposal of the product When the product is discarded dispose it after separation of the AMP in the housing and main sensor There is no part influencing over environment user does not require t...

Страница 9: ... normal operating conditions If troubles that occur are not due to product failure service charge will apply You can request A S from our website or by contacting our headquarters Headquarters Factory and Research Center Contacts Address Hitrol 141 Palhakgol gil Jori eup Paju si Gyeonggi do Republic of Korea Palhakgol gil 98 HITROL CO LTD 141 Palhakgol road Jori eup Paju si Gyeonggi do Korea TEL 0...

Отзывы: