UMXCBA/UMXCA

 

CONDENSER UNITS WITH 
COMPRESSOR AND AXIAL FAN

 

APPENDIX: SAFETY DATA R410A 

REFRIGERANT DATA 

SAFETY DATA: R410A 

Toxicity 

Low 

Contact with Skin 

R410 A vapours can irritate the skin and eyes. In liquid form, it can freeze skin on contact. If contact with skin 
occurs, flush the exposed area with lukewarm water until all of the chemical is removed. If there is evidence of 
frostbite, bathe in lukewarm water. 

Contact with Eyes 

If contact with eyes occurs, immediately flush with large amounts of lukewarm water for at least 15 minutes, 
lifting eyelids occasionally to facilitate irrigation. Seek medical attention as soon as possible. 

Ingestion 

Very unlikely - should something happen, it will cause frost burns. Do not induce vomiting. Only if the patient is 
conscious, wash out mouth with water and give some 250 ml of water to drink. Then, obtain medical attention. 

Inhalation 

Inhalation of the R410A vapour may cause irritation. Vapour inhalation at high concentrations may result in 
asphyxiation or the heart may become sensitized, causing cardiac arrhythmia. When concentration of R410A 
reach levels which reduce oxygen to 14-16% by displacement, symptoms of asphyxiation will occur. An 
individual exposed to high concentrations of R410A must be given medical attention immediately. Adequate 
ventilation must be provided at all times. 

Recommendations 

Semiotics or support therapy is recommended. Cardiac sensitisation has been observed that, in the presence of 
circulating catecholamines such as adrenalin, may cause cardiac arrhythmia and accordingly, in case of 
exposure to high concentrations, cardiac arrest. 

Prolonged Exposure 

R410A: a study on the effects of exposure to 50,000 ppm during the whole life of rats has identified the 
development of benign testicle tumour. 
This situation should therefore be negligible for personnel exposed to concentrations equal to or lower than 
professional levels. 

Professional Levels 

R410A: Recommended threshold: 1000 ppm v/v - 8 hours TWA. 

Stability 

R410A: without specifying 

Conditions to Avoid 

Do not use in the presence of high temperatures, flames, burning surfaces and excess humidity. 

Hazardous Reactions 

Contact with certain red-hot metals may result in exothermic or explosive reactions and yield toxic and/or 
corrosive decomposition products. Specific materials to avoid include freshly abraded aluminium surfaces and 
active metals such as sodium, potassium, calcium, powdered aluminium, magnesium and zinc. 

Hazardous 

Decomposition 

Products 

R410A: Halogen acids produced by thermal decomposition and hydrolysis. 

General Precautions 

Do not inhale concentrated vapours. Their concentration in the atmosphere should not exceed the minimum 
preset values and should be maintained below the professional threshold. Being weightier than the air, the 
vapour concentrates on the bottom, in narrow areas. Therefore, the exhaust system must work at low level. 

Respiratory System 

Protection 

If you are in doubt about the concentration in the atmosphere, it is recommended to wear a respirator approved 
by an accident prevention Authority, of the independent or oxygen type. 

Storage 

Cylinders must be stored in a cool, dry and properly ventilated storage area away from heat, flames, corrosive 
chemicals, flumes, explosives and be otherwise protected from damage. Keep a temperature below 50°C. 

Protective Clothing 

Wear overalls, protective gloves and goggles or a mask. 

Accidental Release 

Measures 

It is important to wear protective clothing and a respirator. Stop the source of the leak, if you can do this without 
danger. Negligible leaks can be left evaporating under the sun, providing that the room is well ventilated. 
Considerable leaks: ventilate the room. Reduce the leak with sand, earth or other absorbing substances. Make 
sure that the liquid does is not channeled into gutters, sewers or pits where the vapours are likely to create a 
stuffy atmosphere. 

Disposal 

The best method is recovery and recycling. If this method is not practicable, dispose according to an approved 
procedure, which shall ensure the absorption and neutralization of acids and toxic agents. 

Fire Fighting 

Information 

R410A: Not flammable in the atmosphere. 

Cylinders 

The cylinders, if exposed to fire, shall be cooled by water jets; otherwise, if heated, they may explode. 

Protective Fire 

Fighting Equipment 

In case of fire, wear an independent respirator and protective clothing. 

 

Содержание 1602.2

Страница 1: ...2 2402 2 3002 2 3502 2 4002 2 4502 2 Cooling capacity from 25 9 kW to 134 7 kW Heating capacity from 27 3 kW to 142 4 kW CONDENSER UNITS WITH COMPRESSOR AND AXIAL FAN INSTALLATION OPERATION MAINTENAN...

Страница 2: ...ars Our approach is based on efficiency flexibility and on practical solutions This has been the hallmark of our product catalogue The versatility of our factory allows us to deliver solutions that ca...

Страница 3: ...S 12 Refrigerant circuit 12 Discharge lines 12 LINE DESIGN 12 REFRIGERANT LINES 13 LINE DRAWING 13 Additional load in the interconnection pipes 14 REFRIGERATION CONNECTIONS 15 Guidelines for the corre...

Страница 4: ...erature adjustment 24 System operating modes change 24 Time Schedule 25 Local Network 28 Alarms 29 MAINTENANCE 31 CONSERVATION AND CLEANING 31 COMPRESSOR LUBRICANT 32 REFRIGERANT CHARGE 32 DIMENSIONS...

Страница 5: ...the Data The continuous improvement in design and performance to which we are committed to gives us the right to modify the specifications of our products without prior notice Electrical Supply Check...

Страница 6: ...d manipulation reparation or modification of the unit will automatically invalidate the warranty Packaging and Replacement of Equipment The material of the package plastic bags insulating materials na...

Страница 7: ...carry out basic tasks only such as cleaning and replacement of filters or filter cleaning excluding the refrigerant filters etc Prevent access to children to avoid that they play with the equipment Fo...

Страница 8: ...1 5 8 Gas line diameter circuit 1 1 1 8 Liquid line diameter circuit 2 Gas line diameter circuit 2 FAN Type Outdoor Axial Rotor Nominal air flow m3 h 17700 17700 19700 19700 Available static pressure...

Страница 9: ...er circuit 1 5 8 Gas line diameter circuit 1 1 1 8 Liquid line diameter circuit 2 5 8 Gas line diameter circuit 2 1 1 8 FAN Type Outdoor Axial Rotor Nominal air flow m3 h 35400 35400 39400 39400 Avail...

Страница 10: ...circuit 1 7 8 Gas line diameter circuit 1 1 3 8 Liquid line diameter circuit 2 7 8 Gas line diameter circuit 2 1 3 8 FAN Type Outdoor Axial Rotor Nominal air flow m3 h 46400 65900 65900 Available sta...

Страница 11: ...own below Be sure to hoist the machine through the points indicated in the diagram Make sure that the unit is balanced stable and without any deformations during the lifting operations STORAGE If the...

Страница 12: ...transmission of noise and vibration Check that the direction of the sound level will not disturb anybody The standard version of this equipment has been designed for installation inside a building wit...

Страница 13: ...qualified technicians An incorrect design may reduce the unit s performance and may be a hindrance when access to the unit for maintenance operations is needed in particular where there is only one po...

Страница 14: ...ne pressure drop The refrigerant circulation speed The refrigerant mass in the system The length of the interconnection pipes please contact Hitecsa for lines longer than 50 meters Discharge lines In...

Страница 15: ...indoor unit is installed at the same level as the outdoor unit raise the suction line to a higher level than the indoor heat exchanger in order to avoid refrigerant return into the compressor during...

Страница 16: ...2 647 22 9 808 28 6 1 3 8 24 853 120 4 3 241 8 5 481 17 1 722 25 6 963 34 1 1204 42 6 1 5 8 34 1219 172 6 1 344 12 2 688 24 4 1033 36 6 1377 48 8 1721 60 9 2 1 8 61 2149 303 10 7 607 21 5 1213 43 0 18...

Страница 17: ...d leave particles inside the pipe Reduce the number of brazing and remember that it should always be of the strong type In compliance with local laws the welder must be an authorized person A bad weld...

Страница 18: ...ding to the current local laws The interconnecting wires shall be protected by a tube or an electrical cable conduit cable tray etc ELECTRICAL DIAGRAM For further details please refer to the electrica...

Страница 19: ...MXCBA UMXCA CONDENSER UNITS WITH COMPRESSOR AND AXIAL FAN INSTALLATION ELECTRICAL DIAGRAM pGD1 or Mini pGD control Connection to pGD1 via 6 wire telephone cable for lines longer than 50m intercalate w...

Страница 20: ...make the connections Make sure that all electrical connections are properly tight The power supply of the unit must comply with the data stated on the serial plate Damage caused by the start up of th...

Страница 21: ...e unit air flow is too low How to change the fan speed 1 Remove the belt Move the motor along its track or loosen the tensor set screw in order to release it 2 Loose the set screws of the motor pulley...

Страница 22: ...t flexibility is calculated in millimeters by dividing S by 40 OPERATION LIMITS OUTDOOR AIR TEMPERATURE Dry temperature COOLING CYCLE C Minimum conditions 20 Maximum conditions 50 HEATING CYCLE C Mini...

Страница 23: ...or negative that shall be added to the value of the probe A value equal to zero will not change the value of the probe Press keys FAN ON OFF and keep them pressed until a password is required Enter pa...

Страница 24: ...rd Auto will disappear from the icon The fan works in a continuous mode Keep the button pressed during 3 seconds minimum until Clock appears if the stated hour is not correct you can change it here tu...

Страница 25: ...3 disconnected Comp 1 discharge Temperature AL05 Alarm probe B5 disconnected Return humidity AL06 Alarm probe B6 disconnected Return humidity AL07 Alarm probe B7 disconnected Outdoor humidity AL11 Ala...

Страница 26: ...submenu help is shown on the main screen UP KEY Scrolling through the menus or modification of the values of the regulation parameters ENTER KEY Confirmation of the introduced values DOWN KEY Scrollin...

Страница 27: ...hedule pGD1 models as standard HIT005 You will have 4 types of start in time schedule and when the time schedule is ON the screen will display the word PHASE A Manual type by selecting this type of st...

Страница 28: ...from 6 30 to 11 00 etc D ON OFF schedule type with SET limit of ON This option makes the start stop as option B ON OFF schedule including a safety start up of the unit out of the schedule when the tem...

Страница 29: ...2 00 a m Example DST of 60 min Enabled from the first Monday of February at 10 00 goes off at 11 00 until the last Sunday of October at 3 00 goes back at 2 00 The pGD1 is an option HITSAA01 Various ty...

Страница 30: ...5 Press the three buttons until the next image appears again on the screen return the display address setting value to 32 Press Enter to confirm 6 Set I O Board address to the desired value that we e...

Страница 31: ...ALARM MESSAGES pGD1 Optional HITSAA01 Message in Display Type Alarms Clock card error or not connected Warning Alarms Probe B01 broken or disconnected Warning Alarms ThTune offline Alarm Alarms ThTune...

Страница 32: ...m General Alarm of the Burner Alarm Severe Damaged Memory indication Warning Missing Clock or not working Alarm Maintenance of the unit Only indication Warning Alarms Severe Return Temperature Probe B...

Страница 33: ...opped and control that nobody may start it during the intervention A regular inspection of the unit is required to avoid dirt accumulation in propellers turbines motors and grids that could entail ris...

Страница 34: ...or system should not remain open to atmosphere for more than 15 minutes Synthetic ester type lubricants POE Polyol Ester with a high solubility level with R 410A are used These types of oil are very h...

Страница 35: ...7_200201_EN UMXCBA UMXCA CONDENSER UNITS WITH COMPRESSOR AND AXIAL FAN DIMENSIONS UMXCBA UMXCA 801 1 1001 1 1201 1 1501 1 LEGEND 1 Liquid pipes connection 2 Gas pipes connection 3 Electrical box 4 Mai...

Страница 36: ...2 3002 2 CENTRE OF GRAVITY X Y Z UMXBCA 1602 2 684 1056 635 UMXCBA 2002 2 680 1057 670 UMXCBA 2402 2 680 1058 665 UMXCBA 3002 2 685 1058 672 LEGEND 1 Lower inlet for electrical power 2 Electrical box...

Страница 37: ...S WITH COMPRESSOR AND AXIAL FAN DIMENSIONS UMXCBA UMXCA 3502 2 4002 2 4502 2 LEGEND 6 Lower inlet for electrical power 7 Electrical box 8 Main switch 9 Standard inlet for electrical power 10 Connectio...

Страница 38: ...of high temperatures flames burning surfaces and excess humidity Hazardous Reactions Contact with certain red hot metals may result in exothermic or explosive reactions and yield toxic and or corrosi...

Страница 39: ...Subject to modifications without prior notice...

Отзывы: