Item
Content
Output example:
•
G200
1
•
VSP G400, G600 and VSP F400, F600
2
•
VSP G800 and VSP F800
3
Serial Number #
Serial product number (decimal, from 400001 to 499999)
IP Address
IP address
Output example: xxx.xxx.xxx.xxx (decimal, 0 to 255)
Subnet Mask
Subnet mask
Output example: xxx.xxx.xxx.xxx (decimal, 0 to 255)
Number of CUs
Number of CUs (decimal, 0 to 64)
Number of DKBs
Number of DKBs (decimal, 0 to 8)
Zero (0) is sometimes displayed if an HDD is not installed.
Configuration Type
Configuration type
Output example: PCM
Model
Storage system model: S, M, or H
Unified Mode
Unified Mode of the storage system.
•
On: Operating with Unified Mode
•
Off: Not operating with Unified Mode
This item is not displayed for VSP G200.
Notes:
•
To determine if the model type is VSP G200, see
.
○
VSP G200: Install is Enabled for Model upgrade license
•
To determine whether the model type is VSP G400, VSP F400, VSP G600, or VSP F600, see
○
VSP G400: Install is Disabled for both Model upgrade license and All Flash Array
○
VSP F400: Install is Disabled for Model upgrade license and Install is Enabled for All Flash Array
○
VSP G600: Install is Enabled for Model upgrade license and Install is Disabled for All Flash Array
○
VSP F600: Install is Enabled for both Model upgrade license and All Flash Array
•
To determine whether the model type is VSP G800 or VSP F800, see
.
○
VSP G800: Install is Disabled for All Flash Array
○
VSP F800: Install is Enabled for All Flash Array
DkuTempAveInfo.csv
This CSV file contains information about DB temperature for every two hours.
A record is DB temperature information obtained from the environment
monitor. A record output to the first line shows the latest temperature
information. Because DB temperature information is measured by DBPS,
items are displayed in this unit*.
DkuTempAveInfo.csv shows the average temperature as DB temperature
data. The total number of items depends on the model (VSP G200: 17, VSP
G400/VSP G600/VSP F400/VSP F600: 49, VSP G800/VSP F800: 97).
The DB temperature data displayed in DkuTempAveInfo.csv (average
temperature only), DkuTempMaxInfo.csv (maximum temperature only), and
Examples of storage configuration reports
319
System Administrator Guide for VSP Gx00 models and VSP Fx00 models
Содержание VSP F400
Страница 10: ...10 System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...
Страница 16: ...16 Preface System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...
Страница 30: ...30 System administration overview System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...
Страница 136: ...136 Configuring the storage system System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...
Страница 210: ...210 User administration System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...
Страница 244: ...244 Setting up security System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...
Страница 256: ...256 Alert notifications System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...
Страница 270: ...270 Managing license keys System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...
Страница 280: ...280 Managing storage system reports System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...
Страница 350: ...350 Examples of storage configuration reports System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...
Страница 386: ...386 System option modes System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...
Страница 406: ...406 Glossary System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...
Страница 412: ...412 Index System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...
Страница 413: ...System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...