3.
In the folder where the .bat file is located, execute the following
command:
C:\MAPP\wk\Supervisor\MappIniSet>MappSetPortInit.bat
4.
An initialization confirmation message box displays.
If you want to continue, enter
Y
, and then press the
Enter
key. If you
want to cancel the task, enter
N
, and then press the
Enter
key.
5.
A service restart message box displays, followed by a completion
message box. Press any key to acknowledge the message and close the
message box.
6.
Close the Windows command prompt.
Reassigning an automatically assigned port number
You can reassign the port number that is automatically assigned to the
storage system.
If the port number assigned to the storage system is used in another
application, the port number is reassigned. Also, if you disabled the
automatic assign, this deletes the unnecessary port number that is already
assigned.
Caution:
• Stop the storage system service before reassigning. If you did not stop
before reassigning, stop the storage system service in Storage Device List
window, then start the service.
• The port for DeviceJettyStart and DeviceJettyStop that is assigned when
starting the storage system service cannot be reassigned.
• If you disable the function which is using the port, this deletes the port
number that is already assigned.
Procedure
1.
Logout from Device Manager - Storage Navigator on the storage system
that you want to reassign.
2.
Stop the service of the storage system that you want to reassign.
3.
Open the Windows command prompt as administrator on the SVP.
4.
In the folder where the .bat file is located, execute the following
command:
C:\MAPP\wk\Supervisor\MappIniSet>MappPortManageRenum.bat
serial-
number (optional)
Note:
A space is required between
MappPortManageRenum.bat
and
serial-number
.
132
Configuring the storage system
System Administrator Guide for VSP Gx00 models and VSP Fx00 models
Содержание VSP F400
Страница 10: ...10 System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...
Страница 16: ...16 Preface System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...
Страница 30: ...30 System administration overview System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...
Страница 136: ...136 Configuring the storage system System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...
Страница 210: ...210 User administration System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...
Страница 244: ...244 Setting up security System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...
Страница 256: ...256 Alert notifications System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...
Страница 270: ...270 Managing license keys System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...
Страница 280: ...280 Managing storage system reports System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...
Страница 350: ...350 Examples of storage configuration reports System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...
Страница 386: ...386 System option modes System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...
Страница 406: ...406 Glossary System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...
Страница 412: ...412 Index System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...
Страница 413: ...System Administrator Guide for VSP Gx00 models and VSP Fx00 models ...