• When creating a Thin Image cascaded pair with the CTG mode specified
using CCI, a volume belonging to the snapshot group and the following
volumes cannot be contained in the same snapshot group:
○
The P-VOL or S-VOL of a volume belonging to the snapshot group
○
A volume that uses the same P-VOL with a different MU number as the
volume belonging to the snapshot group
Thin Image planning requirements
You must calculate the number of Thin Image pairs you can create.
When you create Thin Image pairs for a P-VOL for the first time, the number
of pairs that you can create in a storage system depends on several
variables.
• The number of Thin Image pairs that you can create based on the number
of available pair tables.
• The snapshot estimated manageable capacity.
• The number of cache management devices that you must make available.
The smallest of the three calculations is the maximum number of Thin Image
pairs that you can create in the storage system.
When you create Thin Image pairs again, you only need to know the number
of pair tables to calculate the number of pairs that you can create. You do not
need to know the snapshot estimated manageable capacity or the number of
cache management devices.
If you have multiple P-VOLs, calculate the number of Thin Image pairs that
you can create for each P-VOL in the storage system.
Calculating the number of Thin Image pairs based on pair tables
Pair tables contain information that is required to manage HTI pairs. Each
HTI pair requires at least one pair table.
The number of HTI pairs that you will need is
maximum-number-of-existing-
pair-tables
-
number-of-existing-pairs
.
Maximum number of pair tables:
• VSP Gx00 models and VSP Fx00 models: 102,400
• VSP G1000, G1500, and VSP F1500: 1,048,575
To view the number of existing HTI pairs, see
summary information on page 157
Calculating Thin Image pairs based on the snapshot estimated
manageable capacity
You can calculate the number of HTI pairs you can create based on the
snapshot estimated manageable capacity.
76
Thin Image system and planning requirements
Hitachi Thin Image User Guide for Hitachi Virtual Storage Platform G Series and F Series
Содержание VSP F1500
Страница 124: ...124 Configuring Thin Image Hitachi Thin Image User Guide for Hitachi Virtual Storage Platform G Series and F Series ...
Страница 202: ...202 Troubleshooting Thin Image Hitachi Thin Image User Guide for Hitachi Virtual Storage Platform G Series and F Series ...
Страница 203: ...Troubleshooting Thin Image 203 Hitachi Thin Image User Guide for Hitachi Virtual Storage Platform G Series and F Series ...
Страница 205: ...Troubleshooting Thin Image 205 Hitachi Thin Image User Guide for Hitachi Virtual Storage Platform G Series and F Series ...
Страница 320: ...320 Glossary Hitachi Thin Image User Guide for Hitachi Virtual Storage Platform G Series and F Series ...
Страница 324: ...324 Index Hitachi Thin Image User Guide for Hitachi Virtual Storage Platform G Series and F Series ...
Страница 325: ...Hitachi Thin Image User Guide for Hitachi Virtual Storage Platform G Series and F Series ...