Appendix
C:
Environmental specifications for
VSP G800
The environmental specifications are described for the storage system.
Environmental specifications
Temperature
Caution: The following VSP Gx00/Fx00 storage system components are not
supported in high-temperature environments. Do not operate the following
components at temperatures of 40°C or higher:
■
DB60 dense drive tray
■
HDS provided service processor (SVP) server
■
First-generation FMDs (non-DC2 FMDs)
State
Controller
SFF, LFF drive
trays
Dense intermix drive tray
Operating
50°F to 104°F
(10°C to 40°C)
50°F to 104°F
(10°C to 40°C)
50°F to 95°F (10°C to 35°C)
Non-operating
14°F to 122°F
(-10°C to 50°C)
14°F to 122°F
(-10°C to 50°C)
14°F to 122°F (-10°C to 50°C)
Transport,
storage
-22°F to 140°F
(-30°C to 60°C)
-22°F to 140°F
(-30°C to 60°C)
-22°F to 140°F (-30°C to 60°C)
Temperature
change rate
(°C/h)
10 or less
State
Controller
FMD drive trays
Operating
50°F to 104°F
(10°C to 40°C)
DKC-F710I-1R6FM or DKC-F710I-3R2FM drive is
installed: 50°F to 95°F (10°C to 35°C)
Appendix C: Environmental specifications for VSP G800
Hitachi Virtual Storage Platform G800 Hardware Reference Guide
75