background image

Appendix

 

G:

 

 Port address mapping

Port address mapping

Each fibre channel port has a default port address (AL_PA) of EF. You do not have to

change this value because the storage system port can connect to the host bus adapter

(HBA) with the current setting.
If you want to change the AL_PA value, however, select a value from the following table.
If you use a value that is not in the following table or is already used by the HBA, the host

might not be able to recognize the VOL. If this problem or other problems occur, revert

to the default value of EF.

EF*

CD

B2

98

72

55

3A

25

E8

CC

B1

67

7

64

39

23

E4

CB

AE

90

6E

53

36

1F

E2

CA

AD

8F

6D

52

35

1E

E1

C9

AC

88

6C

51

34

1D

E0

C7

AB

84

6B

4E

33

1B

DC

C6

AA

82

6A

4D

32

18

DA

C5

A9

81

69

4C

31

17

D9

C3

A7

80

67

4B

2E

10

D6

BC

A6

7C

66

4A

2D

0F

D5

BA

A5

7A

65

49

2C

08

D4

B9

A3

79

63

47

2B

04

D3

B6

9F

76

5C

46

2A

02

D2

B5

9E

75

5A

45

29

01

D1

B4

9D

74

59

43

27

N/A

CE

B3

9B

73

56

3C

26

N/A

* A value set as the default value.

Appendix G: Port address mapping

Hitachi Virtual Storage Platform G800 Hardware Reference Guide

111

Содержание Virtual Storage Platform G800

Страница 1: ...0 83 05 2x Hardware Reference Guide This document provides information about the system hardware components mechanical and environmental specifications for the Hitachi Virtual Storage Platform G800 storage system MK 94HM8026 11 April 2018 ...

Страница 2: ... from authorized employees and other individuals and 2 Verifying that your data continues to be held retrieved deleted or otherwise processed in accordance with relevant laws Notice on Export Controls The technical data and technology inherent in this Document may be subject to U S export control laws including the U S Export Administration Act and its associated regulations and may be subject to ...

Страница 3: ... Unified configuration 13 VSP G800 model 13 Features 16 Scalability 16 Examples of supported VSP G800 configurations 17 Maximum number of mounted drive trays 17 Chapter 2 Virtual Storage Platform G800 controller 18 CBLH controller 18 CBLH with front panel bezel 18 CBLH front panel LEDs without bezel 19 CBLH rear panel 21 CBLH power supply unit LEDs and connectors 23 Host Network and Drive Tray Por...

Страница 4: ...r supply unit LEDs and connectors 37 Large form factor drive tray DBL 37 LFF with front panel bezel 38 LFF front panel without bezel 38 LFF rear panel 39 SFF and LFF AC power supply unit LEDs and connectors 40 SFF power supply unit LEDs and connectors 41 Flash module drive tray DBF 41 FMD with front panel bezel 42 FMD front panel without bezel 43 FMD rear panel 44 High density intermix drive tray ...

Страница 5: ...e system 61 Removing cables 62 Appendix A Mechanical specifications for VSP G800 63 VSP G800 mechanical specifications 63 Appendix B Electrical specifications for VSP G800 73 Electrical specifications 73 Appendix C Environmental specifications for VSP G800 75 Environmental specifications 75 Appendix D iSCSI standards and specifications 80 iSCSI standards 80 iSCSI specifications 80 Appendix E Repla...

Страница 6: ...rty rack support for DB60 dense intermix drive trays 113 Appendix I Power distribution units for Hitachi Universal V2 Rack 115 Americas single phase PDU 1P30A 8C13 3C19UL P 115 Americas single phase PDU 1P30A 15C13 3C19UL P 116 Americas three phase PDU 3P30A 8C13 3C19UL P 116 Americas three phase PDU 3P30A 15C13 3C19UL P 117 Americas three phase PDU 3P30A 24C13 6C19UL P 118 APAC and EMEA single ph...

Страница 7: ...Appendix J Regulatory compliance 125 Appendix K Safety and environmental notices 127 Index 129 Contents Hitachi Virtual Storage Platform G800 Hardware Reference Guide 7 ...

Страница 8: ...nt revision applies to the following product versions VSP G800 firmware 83 05 2x or later Hitachi Storage Virtualization Operating System SVOS 7 4 0 or later Hitachi NAS firmware version 13 1 or later Release notes Read the release notes before installing and using this product They may contain requirements or restrictions that are not fully described in this document or updates or corrections to ...

Страница 9: ...ndicates variables in the following scenarios Variables are not clearly separated from the surrounding text or from other variables Example Status report name file version csv Variables in headings square brackets Indicates optional values Example a b indicates that you can choose a b or nothing braces Indicates required or expected values Example a b indicates that you must choose either a or b v...

Страница 10: ...lculated based on the following values Physical capacity unit Value 1 kilobyte KB 1 000 103 bytes 1 megabyte MB 1 000 KB or 1 0002 bytes 1 gigabyte GB 1 000 MB or 1 0003 bytes 1 terabyte TB 1 000 GB or 1 0004 bytes 1 petabyte PB 1 000 TB or 1 0005 bytes 1 exabyte EB 1 000 PB or 1 0006 bytes Logical capacity values for example logical device capacity cache memory capacity are calculated based on th...

Страница 11: ...tachi Vantara Support Connect for contact information https support hitachivantara com en_us contact us html Hitachi Vantara Community is a global online community for Hitachi Vantara customers partners independent software vendors employees and prospects It is the destination to get answers discover insights and make connections Join the conversation today Go to community hitachivantara com regis...

Страница 12: ...ide file access through CIFS and NFS protocols and block access by using iSCSI protocols All storage system models allow defective drives to be replaced without the interruption of data availability to hosts A hot spare drive can be configured to replace a failed drive automatically securing the fault tolerant integrity of the logical drives Self contained hardware based RAID logical drives provid...

Страница 13: ...using drive trays connected to the controllers The CBLH can be expanded by mounting a host port expansion chassis The storage system supports 512 GB of high speed cache memory The DIMMs are arranged as 256 GB per controller Storage system interfaces are listed in the following table The maximum number of ports can be increased by connecting a host port expansion chassis Front end module Without ho...

Страница 14: ...S power supply contains BNST DW F800 DBSC 2 5 inch SFF 24 2U 86 2 mm DBL DW F800 DBL power supply contains BNST DW F800 DBLC 3 5 inch LFF 12 2U 86 2 mm DBF DW F800 DBF 5 25 inch FMD 12 2U 86 2 mm DBF DW F800 DBF 5 25 inch FMD 40 2 spares 2U 86 2 mm DB60 DW F800 DB60 power supply contains BNST DW F800 DB60C 3 5 inch LFF 60 4U 174 3 mm Disk drives The VSP G800 storage system supports the listed disk...

Страница 15: ...rive 10 TB Flash module drives The VSP G800 storage system supports the listed flash module drive capacities Model number Drive type Drive capacity DKC F810I 1R6FN FMD 1 75 TB 1 6 TiB DKC F810I 3R2FN FMD 3 5 TB 3 2 TiB DKC F810I 6R4FN FMD 7 TB 6 4 TiB DKC F810I 7R0FP FMD 7 TB DKC F810I 14RFP FMD 14 TB Solid state drives The VSP G800 storage system supports the listed SSD capacities Model number Dr...

Страница 16: ...aximum number of DP pool volumes 4 096 Maximum number of DP pools 64 Maximum number of iSCSI hosts connected through a network switch 255 Maximum number of Fibre Channel devices connected through a Fibre Channel switch 255 Maximum storage system capacity physical capacity Using 2 4 TB HDD 2 656 TB Using 10 TB HDD 14 098 TB Using 7 6 TB SSD 8 711 TB Using 14 TB FMD 8 106 TB Scalability All storage ...

Страница 17: ...240 slots per path the drive is blocked Maximum number of mounted drive trays The following table lists the maximum number of mountable drive trays and mountable drives for each drive type Note If a drive is inserted into a slot of a dense intermix drive tray when the installed number of drives exceeds 240 slots per path the drive is blocked VSP G800 controller Drive trays Maximum number of trays ...

Страница 18: ...emain available to data hosts using a redundant data path through the other controller The controller is equipped with LED indicators for monitoring its operating conditions and notifying possible component replacement CBLH controller The CBLH controller includes specific functional LEDs located on the front and rear of controller and power supplies to provide its operating status CBLH with front ...

Страница 19: ...might be down Go to the Customer Contact Us page at https support hds com en_us contact us html 5 POWER ON OFF main switch Powers the storage system 6 Lock Locks and unlocks the front panel bezel by using the supplied key Note Removing a controller can cause the POWER READY WARNING and ALARM LEDs on the front panel to turn off These LEDs return to the on status after the storage system recovers fr...

Страница 20: ...rs Controller 1 bottom and Controller 2 top 4 Backup module N A 5 BACKUP LED Green Power restoration in progress following power outage Fast blink green Restoring Slow blink green Restoring or sequential shutdown in progress 6 Cache flash memory N A 7 ALM LED for cache flash memory Red Cache flash memory can be removed 8 CTL ALM LED Red Controller can be removed CBLH front panel LEDs without bezel...

Страница 21: ...d two times Backup battery failure Blink red three times Both batteries failed or preventive maintenance replacement of batteries can run Off Battery is not mounted battery mounting failure occurred or firmware is being upgraded Off is normal status for configurations without batteries for example BKMF 10 and BKMF 20 CBLH rear panel The following table describes the definitions of the CBLH control...

Страница 22: ...upply unit 2 Front end module 3 Back end module 4 LAN blade Rear view includes NAS modules CBLH rear panel Chapter 2 Virtual Storage Platform G800 controller Hitachi Virtual Storage Platform G800 Hardware Reference Guide 22 ...

Страница 23: ...ed 2 Receptacle Connects to the power cable provided with the storage system 3 RDY LED Green Normal operation Host Network and Drive Tray Ports and LEDs The controllers are equipped with specific interfaces for connecting powering configuring and managing the storage system The component LEDs display the operating status of the storage system CBLH power supply unit LEDs and connectors Chapter 2 Vi...

Страница 24: ...module is in the power on state Red Front end module can be removed safely 2 PORT LED Red Small form factor pluggable can be removed Blue Normal link status Blink blue Front end module is in communication status 3 iSCSI connectors Connect to Ethernet cables 10 Gbps iSCSI board LEDs and connectors copper Front end module descriptions Chapter 2 Virtual Storage Platform G800 controller Hitachi Virtua...

Страница 25: ...Gbps link Off No link connection 3 PORT LED Green Link connection is established Blinking Communication is in progress Off No link connection or not ready to communicate 4 iSCSI connectors Connect to Ethernet cables 10 Gbps iSCSI board LEDs and connectors copper Chapter 2 Virtual Storage Platform G800 controller Hitachi Virtual Storage Platform G800 Hardware Reference Guide 25 ...

Страница 26: ...or pluggable can be removed Blue Normal link status at 8 Gbps Green Normal link status at 2 Gbps or 4 Gbps Table 2 32 Gbps 16 Gbps Fibre Channel Number Item Description 1 Fibre Channel connectors Connect to Fibre Channel cables 2 STATUS LED Green Front end module is in power on state Red Front end module can be removed safely 8 Gbps 16 Gbps or 32 Gbps Fibre Channel 4 port board LEDs and connectors...

Страница 27: ...re Channel Ports left to right Port 1 Port 2 Port 3 Port 4 CHB 1A 1A 3A 5A 7A CHB 1B 1B 3B 5B 7B CHB 1C 1C 3C 5C 7C CHB 1D 1D 3D 5D 7D CHB 1E 1E 3E 5E 7E CHB 1F 1F 3F 5F 7F CHB 1G 1G 3G 5G 7G CHB 1H 1H 3H 5H 7H CHB 2A 2A 4A 6A 8A CHB 2B 2B 4B 6B 8B CHB 2C 2C 4C 6C 8C CHB 2D 2D 4D 6D 8D CHB 2E 2E 4E 6E 8E CHB 2F 2F 4F 6F 8F CHB 2G 2G 4G 6G 8G 8 Gbps 16 Gbps or 32 Gbps Fibre Channel 4 port board LED...

Страница 28: ...s in the power on state Red Front end module can be removed safely 2 PORT LED Red Small form factor pluggable can be removed Blue Normal link status at 16 Gbps Green Normal link status at 4 Gbps or 8 Gbps 3 Fibre Channel connectors Connect to Fibre Channel cables 16 Gbps Fibre Channel 2 port board LEDs and connectors Chapter 2 Virtual Storage Platform G800 controller Hitachi Virtual Storage Platfo...

Страница 29: ...C 1C 3C CHB 1D 1D 3D CHB 1E 1E 3E CHB 1F 1F 3F CHB 1G 1G 3G CHB 1H 1H 3H CHB 2A 2A 4A CHB 2B 2B 4B CHB 2C 2C 4C CHB 2D 2D 4D CHB 2E 2E 4E CHB 2F 2F 4F CHB 2G 2G 4G CHB 2H 2H 4H PCIe module PCIe module Chapter 2 Virtual Storage Platform G800 controller Hitachi Virtual Storage Platform G800 Hardware Reference Guide 29 ...

Страница 30: ...ule can be removed safely 2 Link Green PCIe is Gen 3 8 Gbps and is linked up normally Off PCIe is not linked up PCIe cable might not be connected If a PCIe cable is connected it can be removed safely PCIe module Chapter 2 Virtual Storage Platform G800 controller Hitachi Virtual Storage Platform G800 Hardware Reference Guide 30 ...

Страница 31: ...tenance LAN port used by service personnel 5 LAN ALARM LED Red LAN blade can be removed 6 Uninterruptible power supply UPS port N A Back end module LEDs and connectors The back end module LEDs display the operating status of the module LAN blade LEDs and connectors Chapter 2 Virtual Storage Platform G800 controller Hitachi Virtual Storage Platform G800 Hardware Reference Guide 31 ...

Страница 32: ...le can be removed safely 2 Port LED Blue Link status is normal 3 PATH 0 connector Connect to a drive tray 4 PATH 1 connector Connects to a drive tray Back end module LEDs and connectors Chapter 2 Virtual Storage Platform G800 controller Hitachi Virtual Storage Platform G800 Hardware Reference Guide 32 ...

Страница 33: ...e across all host connection ports conventional hard disk drives HDD are not included or configurable with all flash arrays Small form factor drive tray DBS The following describes the physical specifications of the small form factor drive tray Name Model name Height Number of drive slots Drive type DBS DW F800 DBSC 2U 88 2 mm 24 2 5 inch SFF SFF with front panel bezel Number Item Description 1 PO...

Страница 34: ... using the supplied key SFF front panel without bezel Number Item Description 1 ACT LED Green Normal operation Blink green Drive is being accessed 2 ALM LED Red Drive stopped due to a failure and can be replaced 3 POWER READY and LOCATE LEDs Green Drive tray is powered on SFF front panel without bezel Chapter 3 Drive trays Hitachi Virtual Storage Platform G800 Hardware Reference Guide 34 ...

Страница 35: ...inch small form factor drives are positioned vertically The slots are organized from 0 to 23 SFF rear panel Number Item Description 1 ENC N A 2 POWER LED Green ENC is in the power on state 3 LOCATE LED Amber Indicates the location of the chassis Can be turned on or turned off by the maintenance utility SFF rear panel Chapter 3 Drive trays Hitachi Virtual Storage Platform G800 Hardware Reference Gu...

Страница 36: ...r cable provided with the storage system 12 AC IN LED Green Normal operation 13 ALM LED Red Power supply unit can be replaced 14 RDY LED Green Normal operation SFF and LFF AC power supply unit LEDs and connectors Both SFF and LFF drive trays are equipped with AC power supply units The AC power supply units include LEDs to display its operating status Number Item Description 1 RDY LED Green Normal ...

Страница 37: ...Number Item Description 1 RDY LED Green Normal operation 2 DC IN LED Green DC input is operating normally 3 ALM LED Red Power supply unit can be replaced Large form factor drive tray DBL The following describes the physical specifications of the large form factor drive tray Name Model name Height Number of drive slots Drive type DBL DW F800 DBLC 2U 88 2 mm 12 3 5 inch LFF SFF power supply unit LED...

Страница 38: ...on of the chassis Can be turned on or turned off by the maintenance utility 4 Lock Locks and unlocks the front panel bezel by using the supplied key LFF front panel without bezel Number Item Description 1 POWER READY and LOCATE LEDs Green Drive tray is powered on LFF with front panel bezel Chapter 3 Drive trays Hitachi Virtual Storage Platform G800 Hardware Reference Guide 38 ...

Страница 39: ...M LED Red Drive stopped due to a failure and can be replaced 4 Large form factor drives The twelve 3 5 inch large form factor drives are positioned horizontally The slots are organized in the following order 8 9 10 11 4 5 6 7 0 1 2 3 LFF rear panel Number Item Description 1 ENC N A 2 POWER LED Green ENC is in the power on state LFF rear panel Chapter 3 Drive trays Hitachi Virtual Storage Platform ...

Страница 40: ...sole This port is reserved 10 Power supply unit N A 11 Receptacle Connects to the power cable provided with the storage system 12 AC IN LED Green Normal operation 13 ALM LED Red Power supply unit can be replaced 14 RDY LED Green Normal operation SFF and LFF AC power supply unit LEDs and connectors Both SFF and LFF drive trays are equipped with AC power supply units The AC power supply units includ...

Страница 41: ... operating status Number Item Description 1 RDY LED Green Normal operation 2 DC IN LED Green DC input is operating normally 3 ALM LED Red Power supply unit can be replaced Flash module drive tray DBF The following describes the physical specifications of the flash module drive tray Name Model name Height Number of drive slots Drive type DBF DW F800 DBF 2U 87 mm 12 Flash module drive FMD SFF power ...

Страница 42: ...ray is operational 3 LOCATE LED Amber Indicates the location of the chassis Can be turned on or turned off by the maintenance utility 4 Lock Locks and unlocks the front panel bezel by using the supplied key FMD with front panel bezel Chapter 3 Drive trays Hitachi Virtual Storage Platform G800 Hardware Reference Guide 42 ...

Страница 43: ...ks for about two to five minutes until the startup processing is complete ALM LED Red Drive stopped due to a failure and can be replaced Note ACT indicator is only printed on some types of FMDs 3 POWER READY and LOCATE LEDs Green Drive tray is powered on Green Drive tray is operational FMD front panel without bezel Chapter 3 Drive trays Hitachi Virtual Storage Platform G800 Hardware Reference Guid...

Страница 44: ...Slots are organized the following way 9 10 11 6 7 8 3 4 5 0 1 2 FMD rear panel Number Item Description 1 ENC N A 2 POWER LED Green ENC is in the power on state 3 LOCATE LED Amber Indicates the location of the chassis Can be turned on or turned off by the maintenance utility FMD rear panel Chapter 3 Drive trays Hitachi Virtual Storage Platform G800 Hardware Reference Guide 44 ...

Страница 45: ...orage system 11 Three LEDS top to bottom RDY LED AC IN LED ALM REPLACE LED Green Power supply unit is operating normally Green Power supply unit is operating normally Red Power supply unit can be replaced High density intermix drive tray DB60 The following describes the physical specifications of the high density drive tray Name Model name Height Number of drive slots Drive type DB60 DW F800 DB60C...

Страница 46: ...ray is operational 3 LOCATE LED Amber Indicates the location of the chassis Can be turned on or turned off by the maintenance utility 4 Lock Locks and unlocks the front panel bezel by using the supplied key Dense intermix drive tray with front panel bezel Chapter 3 Drive trays Hitachi Virtual Storage Platform G800 Hardware Reference Guide 46 ...

Страница 47: ...nd can be replaced Note At the rear of the drive tray the drives are organized from left to right On the left side of the preceding figure the rear of the drive tray is at the top Rear of drive tray 48 59 36 47 24 35 12 23 Front of drive tray 00 11 Dense intermix drive tray display LEDs Chapter 3 Drive trays Hitachi Virtual Storage Platform G800 Hardware Reference Guide 47 ...

Страница 48: ...able provided with the storage system 6 ENC N A 7 PATH OUT LED Blue OUT side port is linked up 8 PATH OUT connector Connect to a drive tray 9 PATH IN LED Blue IN side port is linked up 10 PATH IN connector Connects to a controller or drive tray 11 Console This port is reserved 12 ALARM LED Red ENC can be replaced Dense intermix drive tray rear panel Chapter 3 Drive trays Hitachi Virtual Storage Pl...

Страница 49: ...he location of the chassis Can be turned on or turned off by the maintenance utility 14 POWER LED Green ENC is in the power on state Dense intermix drive tray rear panel Chapter 3 Drive trays Hitachi Virtual Storage Platform G800 Hardware Reference Guide 49 ...

Страница 50: ...s iSCSI and FC cards For more information contact customer support Host port expansion chassis front panel bezel LEDs Number Item Description 1 POWER LED Green Host port expansion is turned on Amber PCIe module is turned on Off PCIe module is turned off 2 Safety lock Lock or unlock the front bezel PCIe switchboard Chapter 4 Host port expansion chassis Hitachi Virtual Storage Platform G800 Hardware...

Страница 51: ...is powered on Red PCIe switchboard can be replaced safely Off PCIe switchboard is powered off Host port expansion chassis fan Host port expansion chassis fan Chapter 4 Host port expansion chassis Hitachi Virtual Storage Platform G800 Hardware Reference Guide 51 ...

Страница 52: ...scription 1 ALM LED Red Fan failure has occurred Off Normal operation PCIe cable connector PCIe cable connector Chapter 4 Host port expansion chassis Hitachi Virtual Storage Platform G800 Hardware Reference Guide 52 ...

Страница 53: ...o link down and cables Cables can be removed safely Off Basic PCIe is normal or not set 4 Link Option LED Green Option PCIe Gen 3 0 8 Gbps is linked up normally Off Option PCIe is not linked up PCIe cable might not be connected If a cable is connected it can be removed safely 5 InAct Option LED Amber Option PCIe status changed from link up to link down and cables Cables can be removed safely Off O...

Страница 54: ...pansion chassis power supply can be replaced safely Green Normal operation 2 AC IN LED Blue AC input is normal Host port expansion chassis power supply Chapter 4 Host port expansion chassis Hitachi Virtual Storage Platform G800 Hardware Reference Guide 54 ...

Страница 55: ...a block or file system configuration Note The NAS module is not supported on the VSP G200 storage system NAS Module Ports and LEDs Legend Name Color Description 1 User LAN port This is used with the file level access Chapter 5 NAS module Hitachi Virtual Storage Platform G800 Hardware Reference Guide 55 ...

Страница 56: ...t group 6 2 Cluster port Reserved for future use 3 Status LED Green NAS modules are functioning normally Red NAS modules can be removed 4 Link LED Blue Displays link status 5 Fail LED Red A failure has occurred NAS Module Ports and LEDs Chapter 5 NAS module Hitachi Virtual Storage Platform G800 Hardware Reference Guide 56 ...

Страница 57: ... software application supplied by Hitachi Vantara For the latest interoperability updates and details see the SVP Service Processor OS and Hypervisor support for Gx00 Fx00 report at https support hitachivantara com en_us interoperability html Service processor hardware specifications The following table lists the hardware specifications for the service processor SVP provided by Hitachi Vantara Cau...

Страница 58: ...ovides four RJ 45 ports Two ports connect to the storage system controllers one port for each controller One port connects to the IP network of the user One port connects to a user supplied management console PC Note This product is also designed for IT power distribution systems with phase to phase voltage Three of the four RJ 45 ports which connect to the controllers and the IP network are confi...

Страница 59: ...tp 192 168 0 15 dev storage 8360004456789 emergency do Users are responsible for adopting the appropriate security procedures with the SVP including Applying Windows security patches Turning on automatic Windows updates or using the manual Windows update method Installing antivirus software that has been tested and approved by Hitachi SVP front panel The front panel of the physical SVP is equipped...

Страница 60: ... with the SVP 2 Four LAN ports arranged as follows LAN3 LAN4 LAN1 LAN2 These ports connect to your IP network the management console PC and the user LAN port on each storage system controller Note After the Initial Startup Wizard is run the SVP can be used in non bridge mode In this mode the cables can be removed from SVP ports LAN3 and LAN4 and attached to switches For more information contact cu...

Страница 61: ...blinking status 2 Release the main switch and the POWER LED returns to solid green after blinking for approximately three seconds The power off process begins The process takes approximately 18 minutes or longer depending on the amount of data that needs to be written The POWER LED is solid green during the powering off process The POWER LED changes from green to amber when the process is complete...

Страница 62: ...e top of the connector of the optical cable 1 to release the latch and remove the SAS cable 2 To remove a LAN cable push the top of the LAN cable connector 1 to release the latch and remove the LAN cable 2 To remove a PCIe cable pull the tab of the PCIe cable 1 to release the latch and remove the PCIe cable 2 Removing cables Chapter 7 Maintaining the storage system Hitachi Virtual Storage Platform...

Страница 63: ...nical specifications Controller Quantity Component Description 1 CBLH A 4U controller chassis consisting of controllers channel boards disk boards NAS module optional AC or DC power supplies and batteries with cooling fans Appendix A Mechanical specifications for VSP G800 Hitachi Virtual Storage Platform G800 Hardware Reference Guide 63 ...

Страница 64: ...ay A drive tray that supports flash module drives and consists of an ENC and AC DC power supplies equipped with built in cooling fans 1 Dense intermix drive tray DB60 A drive chassis that supports a variety of drive types such as 2 5 inch drives 3 5 inch drives and flash drives The chassis consists of an ENC and AC DC power supplies equipped with built in cooling fans NAS module Component Descript...

Страница 65: ...79 1729 29 2305 58 3916 14 5874 22 9790 36 GB Flash module drive tray 1759 21 3518 43 7036 87 14073 74 GB Only available for DB60 DB60C dense intermix drive tray Rotational speed min 1 Component Specification 2 5 inch drive SFF 288 20 GB 15 000 RPM 576 39 GB 10 000 or 15 000 RPM 1152 79 GB 10 000 RPM 1729 29 GB 10 000 RPM 2305 58 GB 10 000 RPM 3 5 inch drive LFF and dense intermix drive tray DB60 ...

Страница 66: ...h module drive tray 12 Maximum number of flash module drives 576 Maximum number of spare drives 64 Battery specifications Storage system intake temperature CBLH Up to 75 2º F 24º C 5 years Up to 86º F 30º C 5 years Up to 93 2º 34º C 4 years Up to 104º 40º C 3 years VSP G800 mechanical specifications Appendix A Mechanical specifications for VSP G800 Hitachi Virtual Storage Platform G800 Hardware Re...

Страница 67: ... copper NAS module Fibre Channel 1000 Mbs VSP G800 maximum number of ports 8 Gbps Fibre Channel optical 64 16 Gbps Fibre Channel optical 2 port 32 16 Gbps Fibre Channel optical 4 port 64 32 Gbps Fibre Channel optical 64 10 Gbps iSCSI optical 32 10 Gbps iSCSI copper 32 VSP F800 maximum number of ports 8 Gbps Fibre Channel optical 48 16 Gbps Fibre Channel optical 24 32 Gbps Fibre Channel optical 48 ...

Страница 68: ... optical 2 port 40 16 Gbps Fibre Channel optical 4 port 80 32 Gbps Fibre Channel optical 80 10 Gbps iSCSI optical 40 10 Gbps iSCSI copper 40 Maximum number of ports host port expansion chassis and NAS module installed 8 Gbps Fibre Channel optical 32 16 Gbps Fibre Channel Optical 2 port 16 16 Gbps Fibre Channel Optical 4 port 32 32 Gbps Fibre Channel Optical 4 port 32 10 Gbps iSCSI optical 16 10 Gb...

Страница 69: ...storage system hardware or software failure Therefore users are requested to back up all data RAID Level SAS SAS 7 2k flash drives mounted RAID 1 2D 2D 4D 4D RAID 5 3D 1P 4D 1P 6D 1P 7D 1P RAID 6 6D 2P 12D 2P 14D 2P Item Specification Maximum number of RAID groups 480 Maximum volume size 3 TB or 4 TB when using the LDEVs of other storage systems Maximum volumes host groups and iSCSI targets 2048 M...

Страница 70: ...oximately 10 minutes Chassis size Component Specification W x D x H CBLH 19 01 x 35 10 x 6 86 inches 483 x 891 7 x 174 3 mm SFF LFF 18 97 x 22 24 x 3 47 inches 482 x 565 x 88 2 mm DBF 19 01 x 30 x 3 42 inches 483 x 762 x 87 mm Dense intermix drive tray 18 97 x 40 51 x 6 92 inches 482 x 1 029 x 176 mm includes the depth of the cable management arms Mass The table lists the values of a maximum confi...

Страница 71: ...FF 2 U DBF 2 U Dense intermix drive tray DB60 4 U If a drive is inserted into a slot of a dense intermix drive tray when the installed number of drives exceeds 240 slots per path the drive is blocked Cache specifications Item Specification Capacity GB 512 NAS module Cache Capacity DDR3 DIMM 8GB x 12 Slot VSP G800 mechanical specifications Appendix A Mechanical specifications for VSP G800 Hitachi V...

Страница 72: ...ng with the Write Cache function disabled When the battery is charged the warning indication disappears and the storage system continues the operation in the Write Cache function The warning indication disappears within six hours Even when the warning is shown normal operation is assured in Write Through Read and write performance is lowered because the Write Cache function is disabled If the stor...

Страница 73: ...current 100V 200V1 2 CBLH 4 0x2 SFF drive tray 2 4x2 1 2x2 LFF drive tray 1 9x2 1 0x2 FMD drive tray 2 6x2 1 3x2 Dense intermix drive tray 3 0x2 Current rating of breaker fuse A 16 0 each electrical Heat value normal kJ h 2810 or less SFF drive tray 1120 or less LFF drive tray 940 or less FMD drive tray 1520 or less Dense intermix drive tray 3460 or less Steady state power VA W 3 CBLH 1600 1560 or...

Страница 74: ...it 2 If one power unit fails another power unit requires electric current for the two power units Therefore plan the power supply facility so that the current carrying capacity for one power unit can provide the total capacity for two power units 3 This table shows the power requirement 100 V or 200 V for the maximum configuration The actual required power might exceed the value shown in the table...

Страница 75: ...tate Controller SFF LFF drive trays Dense intermix drive tray Operating 50 F to 104 F 10 C to 40 C 50 F to 104 F 10 C to 40 C 50 F to 95 F 10 C to 35 C Non operating 14 F to 122 F 10 C to 50 C 14 F to 122 F 10 C to 50 C 14 F to 122 F 10 C to 50 C Transport storage 22 F to 140 F 30 C to 60 C 22 F to 140 F 30 C to 60 C 22 F to 140 F 30 C to 60 C Temperature change rate C h 10 or less State Controlle...

Страница 76: ...ss Humidity State Percentage Operating 8 to 80 Non operating 8 to 90 Transport storage 5 to 95 Maximum wet bulb temperature C 29 non condensing Vibration State m s2 Operating 2 5 or less Within 5 seconds resonance point 10 Hz or less Non operating 5 0 or less at 5 Hz to 300 Hz no damage to product 9 8 1 0 G Within 5 seconds resonance point 10 Hz or less Transport packed 5 0 or less Environmental s...

Страница 77: ...onmental temperature 10 C to 35 C when DKC F710I 1R6FM or DKC F710I 3R2FM drive is installed Operating m 3 000 Environmental temperature 10 C to 32 C 900 Environmental temperature 10 C to 40 C 3 000 Environmental temperature 10 C to 32 C OR 900 Environmental temperature 10 C to 40 C when DKC F810I 1R6FN 3R2FN 6R4FN 7R0FP 14RFP drive is installed Non operating m 60 to 12 000 N A Environmental speci...

Страница 78: ... 40 C Non operating m N A Atmosphere Avoid areas exposed to corrosive gas and salty air Acoustic Noise State Controller SFF LFF Dense intermix drive tray Opera ting 60 dB Environmental temperature 32 C or less 1 60 dB Environmen tal temperature 32 C or less 1 71 dB Environmental temperature 32 C or less 1 2 3 4 Non opera ting 55 dB 55 dB 71 dB Environmental temperature 32 C or less 1 2 3 4 Environ...

Страница 79: ...tal temperature 32 C or less 1 60 dB Environmental temperature 32 C or less 1 2 3 When accessing the dense intermix drive tray do not work for long times at the rear of the rack Non opera ting 55 dB Environmental temperature 32 C or less 1 2 3 4 55 dB Notes 1 The system s internal temperature controls the rotating speed of the fan module Therefore this standard value might be exceeded if the maxim...

Страница 80: ...ndards IEEE 802 1D STP IEEE 802 1w RSTP IEEE 802 3 CSMA CD IEEE 802 3u Fast Ethernet IEEE 802 3z 1000 BASE X IEEE 802 1Q Virtual LANs IEEE 802 3ae 10 Gigabit Ethernet RFC 768 UDP RFC 783 TFTP RFC 791 IP RFC 793 TCP RFC 1157 SNMP v1 RFC 1231 MIB II RFC 1757 RMON RFC 1901 SNMPv2 iSCSI specifications Item Specification Comments iSCSI target function Supported N A iSCSI target function Supported TrueC...

Страница 81: ...ptical OM3 OM2 MMF cable N A Network switch L2 or L3 switch Should comply with IEEE802 3ae Switch cascading Maximum 5 switches or fewer Minimum number of cascading switches is recommended MAC address Per port fixed value Factory setting World Wide Unique value Cannot be changed Maximum transfer unit MTU 1 500 4 500 9 000 bytes Ethernet frame Jumbo frame MTU size greater than 1500 Link aggregation ...

Страница 82: ...lt an iSCSI connection might be delayed When an iSCSI Port IPv6 is set to Enabled verify the IPv6 router is connected to the same network and then set IPv6 global address automatically Subnet mask Supported N A Gateway address Supported N A DHCP N A N A DNS N A N A Ping ICMP ECHO Transmit Receive Supported N A IPsec2 N A N A TCP port number 3260 Changeable among 1 to 65 535 Observe the iSCSI speci...

Страница 83: ...rror recovery by retrying from host Does not support Level 1 and Level 2 Header digest Supported Detects header error or data error with iSCSI communication The storage system follows the host s digest setting If digest is enabled the performance degrades The amount of the degradation depends on factors such as host performance of host and transaction pattern Data digest Supported Maximum iSCSI co...

Страница 84: ...7 operating systems 2 IP Security Authentication and encryption of IP packets The storage system does not support IPsec 3 iqn iSCSI Qualified Name The iqn consists of a type identifier iqn a date of domain acquisition a domain name and a character string given by the individual who acquired the domain Example iqn 1994 04 jp co hitachi rsd d7m t 10020 1b000 tar 4 eui 64 bit Extended Unique Identifi...

Страница 85: ...mbient temperature is 86 F 30 C or less on average Periodic parts replacement is required For customers with maintenance service contracts parts are replaced periodically in keeping with the terms of the contract Note The battery protects the data in the cache memory in an emergency such as a sudden power failure In these cases follow the normal power down procedure If not the battery might reach ...

Страница 86: ...or storage system installation vary according to the specific storage system and network configuration Fibre Channel and iSCSI cables are used to connect the controllers to a customer switch or host Serial Attached SCSI SAS cables are used to connect drive trays to controllers and other drive trays Appendix F Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide 86 ...

Страница 87: ... each controller to a host computer direct connection or to several host computers via an Ethernet switch SAS SAS optical Connects the controller to a drive tray or a drive tray to another drive tray Two SAS cables are provided with each drive tray SAS cables are also used to connect NAS modules to switches Ethernet RJ 45 Four shielded Category 5e or 6a Ethernet cables are required for connecting ...

Страница 88: ...Gbps 492 1 feet 150 meters 8 Gbps 164 feet 50 meters 16 Gbps 115 feet 35 meters 62 5 micron 2 Gbps 328 1 feet 100 meters 4 Gbps 230 feet 70 meters 8 Gbps 69 feet 21 meters Required cables Appendix F Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide 88 ...

Страница 89: ...AL Available Available Available Available default P to P Available Available Available Available Fabric Available Available Available Available For the 16 Gbps Fibre Channel ports and for 16 Gbps SFP added to the 4 port FC 32 Gbps package the combinations between data transfer speeds and connection types are as follows Connecti on type Data transfer speeds for 16 Gbps ports SFPs 2 Gbps 4 Gbps 8 G...

Страница 90: ...o available No available Available Available Available Available default2 Fabric Available Available Available Available Available Available Notes 1 If this combination is specified the maximum transfer speed automatically specified is 8 Gbps 2 If this default value is set Fabric is set to ON automatically Note The five Hitachi FC HBAs also have an alternate option of Fabric Emulation When the HBA...

Страница 91: ...ft 10 km 4 Gbps 493 ft 150 m 1246 72 ft 380 m 1312 3 ft 400 m 8 Gbps 164 04 ft 50 m 493 ft 150 m 623 36 ft 190 m 16 Gbps 114 8 ft 35 m 328 08 ft 100 m 410 1 ft 125 m 32 Gbps 65 62 ft 20 m 229 7 ft 70 m 328 08 ft 100 m Fibre Channel cables Appendix F Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide 91 ...

Страница 92: ...lent to DXLC 2P PC xxM GC50 125 2SR OMx 50 125 μm 62 5 125 μm Multimode Wavelength 850 nm LC connector LC connector LC LC cable longwave DXLC 2PS SPC xxM SMC 10 125 2SR 9 125 μm Singlemode Wavelength 1300 nm The following figure shows the connector used for optical interfaces Fibre Channel cables Appendix F Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide 92 ...

Страница 93: ...ables When constructing an iSCSI system with a direct connection or switch connection consider the following Data transfer rate Maximum length of cable Multimode cable Single mode cable OM2 OM3 OM4 10 Gbps FCoE 269 02 ft 82 m 984 25 ft 300 m 1804 46 ft 550 m Cable specifications for iSCSI optical interface iSCSI cables Appendix F Data and power cables Hitachi Virtual Storage Platform G800 Hardware...

Страница 94: ...ure shows the connector used for optical interfaces The following figure shows the type of optical connector that connects the storage system optical iSCSI ports LC connector type Connector type LC duplex receptacle connector Interval 6 25 mm flat type two rows Cable specifications for 10 Gbps iSCSI copper interface iSCSI cables Appendix F Data and power cables Hitachi Virtual Storage Platform G80...

Страница 95: ...bps 1000BASE T STP use an STP cable that suppresses radio noise RJ 45 Category 6a LAN cable 50 m 10 Gbps 10GBASE T STP use an STP cable that suppresses radio noise RJ 45 The following figure shows a 10 Gbps iSCSI cable iSCSI cables Appendix F Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide 95 ...

Страница 96: ... RFC 1231 MIB II RFC 1757 RMON RFC 1901 SNMPv2 iSCSI specifications Item Specification Comments iSCSI target function Supported N A iSCSI target function Supported TrueCopy only iSCSI ports 2 per interface board VSP Gx00 models Maximum 32 per iSCSI system Connection methods Direct and switch connections Host connections 255 maximum per iSCSI port With Linux software initiator the maximum number de...

Страница 97: ...k aggregation Not supported N A Tagged VLAN Supported N A IPv4 Supported N A IPv6 Supported Note the following precautions When iSCSI Port IPv6 is set to Enabled if the IPv6 global address is set to automatic the address is determined by acquiring a prefix from an IPv6 router If the IPv6 router does not exist in the network the address cannot be determined As a result an iSCSI connection might be ...

Страница 98: ...e network equipment preventing the storage system from communicating through the new port number iSCSI name Both iqn3 and eui4 types are supported The unique iqn value is automatically set when a target is made iSCSI name is configurable Error recovery level 0 zero Error recovery by retrying from host Does not support Level 1 and Level 2 Header digest Supported Detects header error or data error w...

Страница 99: ...mand Dynamic Link Manager Pass switching is achieved Not supported on Windows Vista and Windows 7 operating systems 2 IP Security Authentication and encryption of IP packets The storage system does not support IPsec 3 iqn iSCSI Qualified Name The iqn consists of a type identifier iqn a date of domain acquisition a domain name and a character string given by the individual who acquired the domain E...

Страница 100: ...es and which you can remove without cutting Never bundle network cables with power cables If network and power cables are not bundled separately electromagnetic interference EMI can affect your data stream If you run cables from overhead supports or from below a raised floor include vertical distances when calculating necessary cable lengths If you use overhead cable supports Verify that your supp...

Страница 101: ...re tasks that will be performed on the storage system such as locating specific pathways or connections isolating a fault or adding or removing components Purchase colored cables or apply colored tags Label both ends of every cable to denote the port to which it connects Cable retention Unintentional unplugging or unseating of a power cable can have a serious impact on the operation of an enterpri...

Страница 102: ... intended Power cable assemblies For information about racks and power distribution units PDUs refer to the Hitachi Universal V2 Rack Reference Guide Hitachi power cables consist of three parts Plug Male connector for insertion into the AC outlet providing power The physical design and layout of the plug s contact meet a specific standard Cord Main section of insulated wires of varying length whos...

Страница 103: ...00 240 10 16 CEI 23 50 Italy 200 240 10 16 CEI 23 50 7 Argentina 200 240 10 15 IRAM 2073 Australia 200 240 10 15 AS 3112 China 200 240 10 16 GB 1002 New Zealand 200 240 10 15 AS 3112 8 Denmark 200 240 10 DK 2 5 Israel 200 240 10 16 SI 32 94 Europe 200 240 CEE 7 7 105 India 200 240 6 16 IS 1293 South Africa 200 240 10 16 SABS 164 11 Switzerland 200 240 10 SEV 1011 126 International 200 240 20 IEC 3...

Страница 104: ...erland for a true 16 A application 7 4 wire three phase and earth Physical variations connector size and color indicate amperage rating 8 5 wire three phase earth and neutral Physical variations connector size and color indicate amperage rating AC connections The following table shows and describes the types of AC connections on your storage system Description Receptacle Input rating Reference sta...

Страница 105: ...t rating Reference standards BS 1363 200V 240V 5 BS 1365 3 IEC 83 AS 3112 200V 240V 6 AS C112 Cable and connector AC connections Appendix F Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide 105 ...

Страница 106: ...conductors must be large to meet high amperage requirements Three phase power uses three cycles that are 120 degrees out of phase which never allows the voltage to drop to zero The more consistent voltage derived from the three hot conductors results in smoother current flow and allows small gauge conductors to be used to distribute the same amount of AC power As a result the load balancing and in...

Страница 107: ...r cables available to the storage system Table 3 Power cables Model number Specification DW F800 J1K 2 5 m 2 pole power cable with grounding terminal AC 125 V 13 A or 15 A DW F800 J2H 2 5 m 2 pole power cable with grounding terminal AC 250 V 13 A or 15 A DW F800 J2H5 5 0 m 2 pole power cable with grounding terminal AC 250 V 13 A or 15 A DW F800 J2H10 10 0 m 2 pole power cable with grounding termin...

Страница 108: ...2 DW F800 SCQ3 3 m SAS cable including omega clips 2 DW F800 SCQ5 5 m SAS cable including omega clips 2 DW F800 SCQ10A 10 m SAS optical cable DW F800 SCQ30A 30 m SAS optical cable DW F800 SCQ1HA 100 m SAS optical cable Data and power cable model list Appendix F Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide 108 ...

Страница 109: ... LC optical cable for optical A 6515 HM10L 10 m LC LC optical cable for optical A 6515 HM20L 20 m LC LC optical cable for optical A 6515 HM30L 30 m LC LC optical cable for optical A 6515 HM50L 50 m LC LC optical cable for optical A 6515 HM100L 100 m LC LC optical cable for optical A 6515 HM200L 200 m LC LC optical cable for optical A 6515 HM300L 300 m LC LC optical cable for optical A 6515 JM5L 5 ...

Страница 110: ...l number Specification A 6515 JM300L 300 m LC LC optical cable for optical Data and power cable model list Appendix F Data and power cables Hitachi Virtual Storage Platform G800 Hardware Reference Guide 110 ...

Страница 111: ... might not be able to recognize the VOL If this problem or other problems occur revert to the default value of EF EF CD B2 98 72 55 3A 25 E8 CC B1 67 7 64 39 23 E4 CB AE 90 6E 53 36 1F E2 CA AD 8F 6D 52 35 1E E1 C9 AC 88 6C 51 34 1D E0 C7 AB 84 6B 4E 33 1B DC C6 AA 82 6A 4D 32 18 DA C5 A9 81 69 4C 31 17 D9 C3 A7 80 67 4B 2E 10 D6 BC A6 7C 66 4A 2D 0F D5 BA A5 7A 65 49 2C 08 D4 B9 A3 79 63 47 2B 04...

Страница 112: ...ward each other The area behind the storage system and between the vertical 19 inch mounting posts must be free of PDUs and cable loops Hitachi Universal V2 Rack rail kits Use rail kits to mount the Hitachi Virtual Storage Platform family storage system in a Hitachi Universal V2 Rack The following tables list the rail kit information for the specified storage systems Table 6 Rail kits for VSP Gx00...

Страница 113: ...e size and weight of the DB60 dense intermix drive trays used with VSP Gx00 models pay close special attention when mounted in third party racks When mounting DB60 dense intermix drive trays in third party racks observe the following guidelines and see the following figure Use anti tilt floor plates or ceiling mounted fixing brackets to stabilize the rack Use a rack that is at least 40 94 in 1040 ...

Страница 114: ...Third party rack support for DB60 dense intermix drive trays Appendix H Third party racks Hitachi Virtual Storage Platform G800 Hardware Reference Guide 114 ...

Страница 115: ...able current load on each PDU before plugging the device into the PDU Balance the electrical current load between available PDUs Americas single phase PDU 1P30A 8C13 3C19UL P The following figure and table describes the specifications of the PDU Figure 1 Americas PDU for the Hitachi Universal V2 Rack Single phase PDU 1P30A 8C13 3C19UL P Part Number Region Phase Description 1P30A 8C13 3C19U L P Ame...

Страница 116: ...ption 1P30A 15C13 3C19 UL P Americas Single 208V 30A 24A rated 60Hz 15 IEC C13 3 IEC C19 sockets NEMA L6 30P input power plug 4 5 m 14 76 feet cable Americas three phase PDU 3P30A 8C13 3C19UL P The following figure and table describes the specifications of the PDU Americas single phase PDU 1P30A 15C13 3C19UL P Appendix I Power distribution units for Hitachi Universal V2 Rack Hitachi Virtual Storag...

Страница 117: ...ted 60Hz 8 IEC C13 3 IEC C19 sockets NEMA L15 30P input power plug 4 5 m 14 76 feet cable Americas three phase PDU 3P30A 15C13 3C19UL P The following figure and table describes the specifications of the PDU Americas three phase PDU 3P30A 15C13 3C19UL P Appendix I Power distribution units for Hitachi Universal V2 Rack Hitachi Virtual Storage Platform G800 Hardware Reference Guide 117 ...

Страница 118: ...ted 60Hz 15 IEC C13 3 IEC C19 sockets NEMA L15 30P input power plug 4 5 m 14 76 feet cable Americas three phase PDU 3P30A 24C13 6C19UL P The following figure and table describes the specifications of the PDU Americas three phase PDU 3P30A 24C13 6C19UL P Appendix I Power distribution units for Hitachi Universal V2 Rack Hitachi Virtual Storage Platform G800 Hardware Reference Guide 118 ...

Страница 119: ...0Hz 24 IEC C13 6 IEC C19 sockets NEMA L15 30P input power plug 4 5 m 14 76 feet cable APAC and EMEA single phase PDU 1P32A 9C13 3C19CE P The following figure and table describes the specifications of the PDU APAC and EMEA single phase PDU 1P32A 9C13 3C19CE P Appendix I Power distribution units for Hitachi Universal V2 Rack Hitachi Virtual Storage Platform G800 Hardware Reference Guide 119 ...

Страница 120: ...Hz 9 IEC C13 3 IEC C19 sockets IEC309 Blue 2P E input power plug 4 5 m 14 76 feet cable APAC and EMEA single phase PDU 1P32A 18C13 3C19CE P The following figure and table describes the specifications of the PDU APAC and EMEA single phase PDU 1P32A 18C13 3C19CE P Appendix I Power distribution units for Hitachi Universal V2 Rack Hitachi Virtual Storage Platform G800 Hardware Reference Guide 120 ...

Страница 121: ...60Hz 18 IEC C13 3 IEC C19 sockets IEC309 Blue 2P E input power plug 4 5 m 14 76 feet cable APAC and EMEA three phase PDU 3P16A 9C13 3C19CE P The following figure and table describes the specifications of the PDU APAC and EMEA three phase PDU 3P16A 9C13 3C19CE P Appendix I Power distribution units for Hitachi Universal V2 Rack Hitachi Virtual Storage Platform G800 Hardware Reference Guide 121 ...

Страница 122: ...0Hz 9 IEC C13 3 IEC C19 sockets IEC309 Red 3P N E input power plug 4 5 m 14 76 feet cable APAC and EMEA three phase PDU 3P16A 15C13 3C19CE P The following figure and table describes the specifications of the PDU APAC and EMEA three phase PDU 3P16A 15C13 3C19CE P Appendix I Power distribution units for Hitachi Universal V2 Rack Hitachi Virtual Storage Platform G800 Hardware Reference Guide 122 ...

Страница 123: ...0Hz 15 IEC C13 3 IEC C19 sockets IEC309 Red 3P N E input power plug 4 5 m 14 76 feet cable APAC and EMEA three phase PDU 3P32A 24C13 6C19CE P The following figure and table describes the specifications of the PDU APAC and EMEA three phase PDU 3P32A 24C13 6C19CE P Appendix I Power distribution units for Hitachi Universal V2 Rack Hitachi Virtual Storage Platform G800 Hardware Reference Guide 123 ...

Страница 124: ...32A 24C13 6C19 CE P APAC and EMEA Three 400V max 3x 32A 50Hz 60Hz 24 IEC C13 6 IEC C19 sockets IEC309 Red 3P N E input power plug 4 5 m 14 76 feet cable APAC and EMEA three phase PDU 3P32A 24C13 6C19CE P Appendix I Power distribution units for Hitachi Universal V2 Rack Hitachi Virtual Storage Platform G800 Hardware Reference Guide 124 ...

Страница 125: ... Regulatory compliance This equipment has been tested and certified for compliance with the following standards Appendix J Regulatory compliance Hitachi Virtual Storage Platform G800 Hardware Reference Guide 125 ...

Страница 126: ...N22 KC Korea KN24 KC Korea Electronic emission certifications EN5522 2010 CE EU EN5524 2010 CE EU EN61000 3 2 2006 A1 A2 CE EU EN61000 3 3 2008 CE EU Safety certifications UL and CSA 60950 1 2007 cTUVus USA and Canada EN60950 1 2006 A1 TUV Germany IEC60950 1 2005 A 1 N A All CB countries IEC60950 1 2005 A 1 S Mark Argentina TP TC 004 2011 EAC Russia CNS 14336 1 BSMI Taiwan EN60950 1 2006 A1 CE EU ...

Страница 127: ...lectrical and electronic equipment should be disposed at the end of life separately from your household wastes There are separate collection systems for recycling in the European Union For more information contact the local authority or the dealer where you purchased the product Recycling A nickel metal hydride battery is used in the Cache Backup Battery A nickel metal hydride battery is a resourc...

Страница 128: ... USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE FDA radiation regulation The array complies with FDA radiation performance standard 21 CFR subchapter J EMI regulation This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful i...

Страница 129: ... 86 retention 101 106 CBLH controller CBLH controller continued rear panel 21 with front panel bezel 18 CBLM controller rear panel 21 chassis 50 compliance 125 configuration 12 13 configurations 17 connections AC 104 controllerbattery connectors 18 drive tray ports 18 fan 18 LED indicator 18 power supply unit 18 controllers CBLH 18 D data cable 107 data cables 86 DC power supply units large form f...

Страница 130: ...expansion 50 host port expansion chassis fan 51 front panel bezel LEDs 50 power supply 53 I interconnect adapter Fibre Channel 50 iSCSI 50 PCIe board 50 iSCSI iSCSI continued cable removal 62 cables 93 specifications 80 96 standards 80 96 L LAN blade LEDs and connectors 31 large form factor drive tray AC power supply unit 36 40 DC power supply units 37 41 with front panel bezel 38 large form facto...

Страница 131: ... removing 62 scalability 16 server 57 service processor 57 58 side panels 113 small form factor drive tray AC power supply unit 36 40 DC power supply units 37 41 rear panel 35 with front panel bezel 33 small form factor drive tray continued without bezel 34 small form factor drive tray 33 specifications electrical 73 environmental 75 hardware 57 iSCSI 80 96 mechanical 63 standards 80 standards for...

Страница 132: ...050 2639 USA www HitachiVantara com community HitachiVantara com Regional Contact Information Americas 1 866 374 5822 or info hitachivantara com Europe Middle East and Africa 44 0 1753 618000 or info emea hitachivantara com Asia Pacific 852 3189 7900 or info marketing apac hitachivantara com ...

Отзывы: