The warning indication disappears within six hours. Even when the warning is shown,
normal operation is assured in Write-Through. Read and write performance is lowered
because the Write Cache function is disabled.
If the storage system is not charged for more than six months, the battery can become
overcharged and sustain unrecoverable damage. To avoid this situation, charge the
battery more than 3 hours every six months.
Insulation performance
Item
Specifications
Insulation withstand voltage
AC 1,500 V (100 mA, 1 min)
Insulation resistance
DC 500 V, 10 M Ω or more
VSP G200 mechanical specifications (DC power supply
model)
Controllers
Quantity
Component
Description
1
CBSSD
A SFF controller chassis
consisting of controllers,
channel boards, disk
boards, NAS module
(optional), DC power
supplies, and batteries with
cooling fans.
1
CBSLD
A LFF controller chassis
consisting of controllers,
channel boards, disk
boards, NAS module
(optional), DC power
supplies, and batteries with
cooling fans.
VSP G200 mechanical specifications (DC power supply model)
Appendix A: Mechanical specifications for VSP G200
Hitachi Virtual Storage Platform G200 Hardware Reference Guide
77