![Hitachi RCME-AH1 Скачать руководство пользователя страница 117](http://html.mh-extra.com/html/hitachi/rcme-ah1/rcme-ah1_service-manual_140451117.webp)
3. Servicing
Electrical components
SMGB0082 rev.1 - 07/2015
109
3
1
Pull the fuse housing backwards.
2
Remove the Hex screws and wiring.
3
Remove the Phillips screws and replace the fuse holder.
3+3 Flat screw driver
or 13mm spanner
PFC1-1
PFC3-6
PFC2-4
PFC1-2
PFC3-5
PFC2-3
2 Phillips
screwdriver
4
When reassembling, perform the procedure in the reverse order than removing.
3.6.11 Relays
To remove any of the relays, proceed as follows:
1
Detach the Faston terminal from its connection
2
Remove the 2 screws fixing the relay to the plate.
3
Replace the relay.
Faston terminals
Phillips screws (x2)
4
When reassembling, proceed in the reverse order than removing.