RAK-35_50RPB_IM_English

1 Installation of Hanger , Wall Penetration and Installation of Protection Pipe

 CAUTION

The draining of the water container inside the Indoor unit can be done from the left.
Therefore the hanger must be fixed horizontally or slightly tilted towards the side of
drain hose. Otherwise, condensed water may overflow the water container.

Direct Mounting On The Wall

Please use hidden beams in the wall to hold the hanger.

Screw the hanger at the
positions possibly near the
upper and lower hooks where
the indoor unit is hung. Use 4 or
more screws to fix the hanger.

The  remote  controller 

must  be  slide  in

the  remote  controller 

holder,  in  the  direction 

as  shown  in  the  figure, 

until  it  hooks  at  the 

lower end of the remote 

controller  holder.

Screw  (2  pieces)

Remote 

Controller 

Holder

Remote

Controller

FOR   SERVICE   PERSONNEL   ONLY

SAFETY PRECAUTION

Read the safety precautions carefully before operating the unit.

The contents of this section are vital to ensure safety. Please pay special attention to the following sign.

 WARNING .......... Incorrect methods of installation may cause death or serious injury.
 CAUTION .......... Improper installation may result in serious consequence.

 Make sure to connect earth line.

    This sign in the figures indicates prohibition.

Be sure that the unit operates in proper condition after installation. Explain to customer the proper operation and maintenance of
the unit as described in the user' s guide. Ask a customer to keep this installation manual together with the instruction manual.

 WARNING

Please request your sales agent or qualified technician to install your unit. Water leakage, short circuit or fire may occur if you do the

installation work yourself.

Please observe the installation stated in the installation manual during the process of installation. Improper installation may cause

water leakage, electric shock and fire.

Make sure that the units are mounted at locations which are able to provide full support to the weight of the units. If not, the units may

collapse and impose danger.

Observe the rules and regulations of the electrical installation and the methods described in the installation manual when dealing

with the electrical work. Use cables which are approved official in your country. Be sure to use the specified circuit. A short circuit and

fire may occur due to the use of low quality wire or improper work.

Be sure to use the specified cables for connecting the indoor and outdoor units. Please ensure that the connections are tight after the

conductors of the wire are inserted into the terminals to prevent the external force is being applied to the connection section of the

terminal base. Improper insertion and loose contact may cause over-heating and fire.

Please use the specified components for installation work. Otherwise, the unit may collapse or water leakage, electric shock, fire or

stronger vibration may occur.

Be sure to use the specified piping set for R410A. Otherwise, this may result in broken copper pipes or faults.

When installing or transferring an air conditioner to another location, make sure that air other than the specified refrigerant (R410A)

does not enter the refrigeration cycle. If other air should enter, the pressure level of the refrigeration cycle may increase abnormally

which could result in a rupture and injury.

Be sure to ventilate fully if a refrigerant gas leak while at work. If the refrigerant gas comes into contact with fire, a poisonous gas may

occur.

After completion of installation work, check to make sure that there is no refrigeration gas leakage. If the refrigerant gas leaks into the

room, coming into contact with fire in the fan-driven heater, space heater, etc., a poisonous gas may occur.

Unauthorized modifications to the air conditioner may be dangerous. If a breakdown occurs please call a qualified air conditioner

technician or electrician. Improper repairs may result in water leakage, electric shock and fire, etc.

Be sure to connect the earth line from the power supply wire to the outdoor unit and between

the outdoor and indoor unit. Do not connect the earth line to the gas tube, water pipe, lighting rod or the earth line of the

telephone unit. Improper earthing may cause electric shocks.

When finishing the refrigerant collection (pumping down), stop the compressor and then remove the coolant pipe.

If you remove the refrigerant pipe while the compressor is operating and the service valve is released, air is sucked and a

pressure in the freezing cycle system will build up steeply, causing an explosion or injury.

When installing the unit, be sure to install the refrigerant pipe before starting the compressor.

If the refrigerant pipe is not installed and the compressor is operated with the service valve released, air is sucked and the

pressure level of the refrigeration cycle may increase abnormally which could result in a rupture and injury.

A circuit breaker must be installed  in the house distribution box  for the direct 

connected  power supply  cables to the outdoor  unit. In case  of other installations 

a main switch with a contact gap or more than 3mm has to be installed.

Without  a circuit breaker, the danger of electric shock exists.
Do not install the unit near a location where there is flammable gas. 
The outdoor unit may catch fire if flammable gas leaks around it.
Please ensure smooth flow of water when installing the drain hose. Improper 

installing may wet your funiture.
An IEC approved power cord should be used. Power cord type: NYM.

MODEL

INDOOR UNIT 

The electric cables should neither be reworked nor  added.

Make sure to use an exclusive circuit breaker.

Otherwise fire or electric shock might occur by connection failure, isolation failure or over current. 

Make sure to connect cables to terminal properly and terminal cover should close firmly. 

Otherwise,  over heating at terminal contact, fire or electric shock might occur.
Make sure that there is no dust on  any connected points of electric cables and fix firmly.

Otherwise, fire or electric shock might occur. 

 WARNING

The unit should be mounted at stable, non-vibratory location which can provide

full support to the unit.

 CAUTION

No  nearby  heat  source  and  no  obstruction  near  the  air outlet is allowed.

The  clearance  distances  from  top,  right  and  left  are specified in figure

below.

The location must be convenient for water drainage and pipe connection

with the Outdoor unit.

To avoid interference from noise, please place the unit and its  remote
controller  at  least  1m  from  the  radio  and television.

To avoid any error in signal transmission from the remote controller,  please

put  the  controller  far  away  from  high- frequency machines and high-power

wireless systems.

 CAUTION

THE CHOICE OF MOUNTING SITE

(Please note the following matters and obtain permission from customer  before installation.)

Drill  a  ø65mm  hole  on  wall  which  is

slightly tilted towards the outdoor side.

Drill the wall at a small angle.

Cut the protection pipe according to the

wall thickness.

Empty gap in the sleeve of protection

pipe should be completely sealed with

putty to avoid dripping of rain water into

the room.

Please  ensure  smooth  flow  of  water

when installing the drain hose. Improper

installing may wet your funiture.

An IEC approved power cord should be

used. Power cord type: NYM.

 WARNING

Be sure that the wire is not in contact with any metal in the  wall. 
Please  use  the protection  pipe  as  wire passing through the 
hollow part  of  the  wall  so  as  to prevent  the  possibility  of
damaged by mouse. Unless it seals completely,any air with high 
humidity flows from outdoor and any dew may drop.

Seal with
putty

Protection
pipe

Sleeve of
protection
pipe

Seal with
putty

Outdoor

Indoor

2-5mm

2 Installation Of The Indoor Unit

WALL

1

PIPING FROM THE RIGHT SIDE 

(BACKWARD, DOWNWARD, HORIZONTAL)

Preparation

Connect connecting cord.

Pull out the pipe, connecting
cord and drain hose.

    Installation

Insert the pipe through the wall hole.

1

The  upper  part  of  the  Indoor  unit
is  hanged  on  the hanger.

2

1

1

2

The projection at the lower part 

of the Indoor unit is hooked onto 
the hanger.

Connecting cords, pipe and

drain hose must be laid

together with Vinyl tape.

Cutting Low Cover bush

While installing the pipe from the right, left or bottom

side, use a knife to cut openings as shown in figure.

Then smoothen the edges of openings with a file.

Wall Penetration and Installation of Protection Pipe

Installation  Of  Remote  Controller

 The  remote  controller  can  be  placed  in  its  holder  which  is  fixed  on 

wall  or  beam.

To operate the remote controller at its holder, please ensure that the 

unit  can receive signal transmitted from the controller at the place where 

the  holder is to be fixed.The unit will beep  when signal is received from 

the remote controller . The signal transmission is weaken by the fluorescent 

light. Therefore,  during the installation of the remote control holder, please 

switch on the light, even during day time, to determine the mounting location 

of the holder.

Wall hole

Lift the body
of the unit
upwards and
then force it
downwards.

1

 Hanger

Refrigerating
Pipe

Protection
Pipe

Drain Hose Connecting Cord

Projection

Pipe

Drain hose

Cable

Drain layout of
backward piping

 Hanger

Names of Indoor Components

Direction of Piping

Backward piping
from left

Connection

Figure showing the Installation of Indoor Unit.

Procedures of Installation and Precautions

Procedures to fix the hanger.

1.Drill holes on wall.

(As shown below)

2.Push plug into the holes.

(As shown below)

3.Fix the hanger on wall

with 4.1 x 32 screw.

(As shown in figure below)

Procedures to fix the holder of remote control.

1.Drill holes on wall.(As shown below) 2.Push plug into the holes. (As shown below)

 Remote

Control
Holder

32mm

Wall

ø

m

m8.

4

1  Hanger
2  Screw

Wall

Plug (Procure locally)

 

Screw

20mm

ø

m

m4.

4

Wall

Plug
(Procure
locally)

Ceiling

1

2

above 50mm

 above 

50mm

 above 50mm

m

m0

03 

tu

ob

a

about 

450mm

dn

eb 

to

n t

su

m

The  indoor  piping 
should  be insulated
with  the  enclosed
insulation  pipe.  (If  the

 

insulator  is insufficient,
please use commercial
products.)

2300 mm or more

Plug

3

4

There  are   6   directions 
allowed,namely,backward
piping,  backward   piping
from left,horizontally piping 
from right,horizontally piping 
from left,vertically down from 
right,vertically down from left.

Openings

Openings

Be sure to

completely

seal any 

gap with 

putty.

9

7

8

7

8

RAK-35RPB
RAK-50RPB

No.

Item

Qty

Hanger

Screw for Hanger

AAA size Battery

Remote Controller

1

2

3

4

6

7

8

9

2

2

2

C-case 

Air Cleaning Mesh

Wasabi-Nano Titanium 

Screw for Remote 

Controller Holder

Remote Controller Holder

2

Insulation sheet

5

Wall hole

Weight

Line

1

 Hanger

Level

2

 Screw for Hanger

Drain Hose

Visible outline of the

Indoor Unit

The installation height should be at least 2300 mm or more from the floor.

EN

1

668 mm

37 mm

115 mm

180 mm

160 mm

mm

100

mm

100

193 m

m

900 mm

295 m

m

42.5 m

m

42.5 m

m

772 mm

284 mm

550 mm

275 mm

23 mm

39

 m

m

Отзывы: