background image

Screw for Hanger

( Φ 4 x 3 5 )

HITACHI SPLIT-UNIT AIR CONDITIONER

INSTALLATION MANUAL

 +  –  Screwdriver     Measuring Tape     Knife
Saw

 ø 65mm Power Drill

 Allen Key (      4mm)

Wrench (14, 17, 19, 22mm)
Gas Leakage Detector      Pipe Cutter
Plastic Tape      Pliers      Flare Tool

Carefully read through the procedures of proper
installation before starting installation work.
The sales agent should inform customers regarding
the correct operation of installation.

Tools Needed For Installation Work

SAFETY PRECAUTION

Read the safety precautions carefully before operating the unit.
The contents of this section are vital to ensure safety. Please pay special attention to the following sign.

WARNING ........ Incorrect methods of installation may cause death or serious injury.

CAUTION .........  Improper installation may result in serious consequence.

Be sure that the unit operates in proper condition after installation. Explain to customer the proper way of operating
the unit as described in the user’s guide.

Be sure to use the earth line. Do not place earth line near gas or water pipes, lightning conductor
and the earth line of telephone. Improper earthing may cause electric shocks.

A circuit breaker should be installed depending on the mounting size of the unit. Without a circuit breaker, the
danger of electric shock exists.

Do not install the unit near a location where there is flammable gas. The outdoor unit may
catch fire if flammable gas leaks around it.

Please ensure smooth flow of water when installing the drain hose.

Please request your sales agent or qualified technician to install your unit. Water leakage, short circuit or fire may
occur if you do the installation work yourself.

Please observe the instructions stated in the installation manual during the process of installation. Improper
installation may cause water leakage, electric shock and fire.

Make sure that the units are mounted at locations which are able to provide full support to the weight of the units.
If not, the units may collapse and impose danger.

Observe the rules and regulations of the electrical installation and the methods described in the installation manual
when dealing with the electrical work. Use wire which is specified for the air conditioner. A short circuit and fire
may occur due to the use of low quality wire or improper work.

Be sure to use the specified wire for connecting the indoor and outdoor units. Please ensure that the connections
are tight after the conductors of the wire are inserted into the terminals. Improper insertion and loose contact may
cause over-heating and fire.

Please use the specified components for installation work. Otherwise, the units may collapse or water leakage,
electric shock and fire may occur.

Do not mix any coolant other than R-22 into the cooling circulation path when mounting or shifting the unit. If it
is mixed with air, the high pressure in the circulation path will rise and this may result in broken copper pipes or
faults.

THE CHOICE OF MOUNTING SITE 

 (Please note the following matters and obtain permission from customer before installation).

The unit should be mounted at stable, non-vibratory location which
can provide full support to the unit.

The outdoor unit must be mounted at a location which can sup-
port heavy weight. Otherwise, noise and vibration will increase.

No nearby heat source and no obstruction near the air outlet is
allowed.
The clearance distances from top, right and left are specified in
figure below.
The location must be convenient for water drainage and pipe
connection with the Outdoor unit.
To avoid interference from noise please place the unit and its
remote controller at least 1m from the radio, television and inverter
type fluorescent lamp.
To avoid any error in signal transmission from the remote controller,
please put the controller far away from high-frequency machines
and high-power wireless systems.
The installation height of indoor unit must be 2.3m or more in a
non public area.

Do not expose the unit under direct sunshine or rain. Besides,
ventilation must be good and clear of obstruction.
The air blown out of the unit should not point directly to animals
or plants.
The clearances of the unit from top, left, right and front are specified
in figure below. At least three of the above sides must be open
air.
Be sure that the hot air blown out of the unit and noise do not
disturb the neighbourhood.
Do not install at a location where there is flammable gas, steam,
oil and smoke.
The location must be convenient for water drainage.
Place the outdoor unit and its connection wire at least 1m away
from the antenna or signal line of television, radio or telephone.
This is to avoid noise interference.

TI

N

U
R

O

O

D

NI

Names of Indoor Components

The Length of Indoor Unit

Power Cord

Do not alter the power cord.

Direction of Piping

Figure showing the Installation
of Indoor and Outdoor Unit.

TI

N

U
R

O

O

D

T

U

O

There are 4 directions
allowed, namely, horizontally
perpendicular to the unit,
vertically down from right,
horizontally out from right and
horizontally out to left.
Don't form the piping
downward at the left of the unit.

Installation of Mounting Plate, Wall Penetration and Installation of Protection Pipe

1

The draining of the water container inside the indoor unit can be done from the left.
Therefore the mounting plate must be fixed horizontally or slightly tilted towards the
side of drain hose. Otherwise, condensed water may overflow the water container.

Direct Mounting On The Wall

Please use hidden beams in the wall to hold the mounting plate.

Wall Penetration and Installation of Protection Pipe

Drill a ø 65mm hole on wall
which is slightly tilted
towards the outdoor side.
Drill the wall at a small angle.
Cut the protection pipe
according to the wall
thickness.
Empty gap in the sleeve of
protection pipe should be
completely sealed with putty
to avoid dripping of rain
water into the room.

Procedures of Installation and Precautions

Procedures to fix the mounting plate.

1. Drill holes on wall.

2.Fix the mounting plate on

(As shown below)

wall with 4.1 x 32 screw
(As shown in figure below)

   Installation of the Indoor Unit

2

VERTICALLY DOWNWARD PIPING

  Preparation

Connect power cord.
Pull out the pipe, power cord and drain hose.

  Installation

The upper part of the indoor unit is hanged
on the mounting plate.
The projection at the lower part of the indoor
unit is hooked onto the mounting plate.

Please pull the lower part
of the indoor unit
outwards to check if the
unit is hooked onto the
mounting plate. Improper
installation may cause
vibration and noise.

HORIZONTAL PIPING

  Preparation

Change of Drain Hose and Installation Procedures.

Exchange the location of drain hose and drain cap during horizontal piping as shown
in figure below. Be sure to plug in the drain hose until the insulating material folds upon
itself.

Please use pliers to pull out the drain cap.
(This is an easier way to remove the drain cap).

HORIZONTAL & DOWNWARD PIPING – MAKING OPENINGS

During horizontal or downward piping, use a knife to cut
openings as shown in figure. Then smoothen the edges
of openings with a file.

INSTALLATION OF COOLANT PIPES AFTER CONNECTION

The coolant pipes should be adjusted to fit into the
hole on the wall and then ready for further connection.
The terminals of 2 connected pipes must be covered
with insulator used for terminal connection.
Connect the power cord.
After adjustment, fit the power cord and pipes into
the space available under the indoor unit.

The rubber strap used for
fixing the insulator should
not be tied with great force.
Otherwise, this will damage
heat insulation and causes
water condensation.

THE CONNECTION OF COOLANT PIPE DURING THE
INSTALLATION OF INDOOR UNIT

  Preparation To Install Coolant Pipes

Please fix in the plastic
core after flaring to avoid
plastic chips entering the
pipes.

CAUTION

You are free to choose the side (left or right) for the installation of drain
hose. Please ensure the smooth flow of condensed water of the indoor
unit during installation. (Carelessness may result in water leakage.)

Be sure that the
drain hose is not
loosely connected
or bent.

Be sure that the wire is not
in contact with any metal
in the wall. Please use the
protection pipe as wire
passing through the hollow
part of the wall so as to
prevent the possibility of
damaged by mouse.

Coolant pipes and power cord must be tied together.
The front part of the coolant pipes are at locations
marked with “   ” symbol.

   Installation of Drain Hose

3

Pull this to the front
during the connection
of coolant pipes to
ease task.

  Installation

Hang the indoor unit onto the mounting plate. Use the temporary
stand at the back of the indoor unit to push its lower part 15cm
forwards.

Place the drain hose through the hole on the wall.
Insulate the connecting portion of coolant pipe with insulator.
Connect the power cord.
After adjustment, the power cord and coolant pipes are placed
into the space available under the indoor unit.
The projection of indoor unit must hook to the mounting
plate.

TI

N

U
R

O

O

D

NI

AAA Size Battery

Hanger

Qty

No.

Component’s Name

1

6

2

Remote Controller

Bush

about 1.6m

about
0.9m

20

Cut away shaded
portion, and finish
the edge of the
opening so that
there is no burr.

Connection

Horizontally
perpendicular
to the unit

Pipe

Power cord

Drain hose

Pipe

Rubber strap tied with great force

Pipe

below
5mm

Please bend at a small
radius to form an arc

about 15cm

Projection

Temporary stand

Hook

Power cord

Protection
pipe

Drain
hose

Connected
terminals
of coolant
pipes

Coolant pipes

Power cord

Heat insulation
pipe

Bending
upwards

Stagment
water

Drain

Stagment
water

Openings

Drain cap

Please insert
until here

Drain hose

Please insert
until here

Mounting Plate

Hook

Coolant pipe

Power Cord

Drain Hose

Protection
Pipe

Lift the body
of the unit
upwards and
then force
it downwards.

Mounting
Plate

Projection

Power line, pipe and
drain hose must be
tied together with
plastic tape.

2~5mm

Protection

pipe

Outdoor

Indoor

Seal with

putty

Sleeve of

protection

pipe

WALL

Remove the cap for drain hose installation

Drain cap

Drain hose

Drain hose

Drain cap

Condensed water may leak out if not inserted properly.

Pipe
support

Pull up the pipe after
bending downward

Transform the piping while holding down the lower portion
of pipe-support by hand.

Indoor Unit

Outdoor Unit

RAS-ME10HZ

RAC-ME10HZ

+

RAS-ME14HZ

RAC-ME14HZ

+

In case the pipe length is more than 5m, add refrigerant R22 at
20 gram (ME14HZ)/15 gram (ME10HZ) per every meter exceeds. 

1

2

3

4

5

1

1

WARNING

CAUTION

WARNING

CAUITON

WARNING

CAUITON

CAUITON

Level

Line

Hole for
pipe

Mark

Screw for Mounting plate

Please use more

than 4 screws.

Mounting

Plate

0.85m

CAUITON

CAUITON

CAUITON

CAUITON

CAUITON

CAUITON

CAUITON

External dimension of

indoor unit

450mm

400mm
316mm

20mm

125mm
44mm

42mm

390mm
530mm

780mm

80mm

65mm

45mm

10mm

65mm

65mm

125mm

199mm

280mm

41mm

45mm

wall nole

wall nole

Drain Hose

Drain Hose

Dimension of Mounting Stand of the outdoor unit

500

698

45

300

282

257

The difference in height
between the indoor and
outdoor unit should be
kept below 5m.
The connecting pipe, no
matter big or small,
should all be insulated
with insulation pipe and
then wrapped with plastic
tape. (The insulator will
deteriorate if it is not
wrapped with tape).

The connection of insulated
drain hose.

Please use insulated drain
hose for the indoor piping
(commercial product).

Be sure to
completely
seal any
gap with
putty.

about 0.45m

Maximum pipe

length 10m

above 300mm

must not bend

above 50mm

above 250mm

above 100mm

RAC-ME14HZ

RAC-ME10HZ

ME10HZ

ME14HZ

8m

10m

(For ME10HZ)

(For ME14HZ)

Отзывы: