FOR  SERVICE  PERSONNEL  ONLY 

HITACHI 

SPLIT UNIT AIR  CONDITIONER 

INSTALLATION  MANUAL 

Outdoor  Unit 

RAC-E50YHA  �  RAC-E60YHA 

•  Carefully  read  through  the  procedures  of  proper 

installation  before  starting  installation  work. 

• The sales agent should inform customers regarding 

the  correct  operation  of  installation. 

Tools Needed For Installation Work 

(  (II)  mark  is  tool  exclusive  use  for  R32) 

• 0 0 

Screwdriver  • Measuring Tape  •  Knife 

• Saw  • Pipe Cutter • Hexagonal Wrench  Key (  IO  4mm) 

•  Power  Drill  (0  65mm  - 0  80mm)  •  Vacuum  Pump

Pliers  or  Wrench •  Torque  Wrench

•  Vacuum

Pump  Adaptor  •  Flare  Tool  •  Gas  Leakage  Detector 

Manifold Valve  • Charge Hose  • Reamer  • File 

Refrigerant pipe size  (outer diameter):  Narrow pipe,  Liquid  (06.35mm);  Wide pipe,  Gas  (012.70mm) 

SAFETY  PRECAUTION 

•  Read the  safety  precautions  carefully  before  operating  the  unit. 

•  The  contents  of  this  section  are vital  to  ensure safety.  Please pay  special  attention  to  the  following  sign. 

Lt, 

WARNING  ........ Incorrect  methods  of installation may  cause  death  or  serious  injury.

Lt, 

CAUTION ......... Improper installation may  result  in  serious consequence.

Be  sure  that  the  unit  operates  in  proper  condition  after  installation.  Explain  to  customer  the  proper  way  of 

operating the  unit  as described in  the user's guide. 

,6WARNING 

•  Flare  nut  must  use  a  torque  wrench  without  fail.  lighten  with  the  specified  tightening  torque.  If  the  flare  nut  is 

tightened  too  much,  after  a  long  period  of  time,  the  flare  nut  breaks,  Gas  leakage,  stagnation,  touching  fire,  rarely 

cause  ignition. 

•  Sharp bending of the pipe use the polyethylene rod,  bend not crushed the pipe.  Gas leakage from the crushed part, 

stagnation,  touching  fire,  rarely  cause  ignition. 

•  Please  request  your  sales  agent  or  qualified  technician  to  install  your  unit.  Water  leakage,  short  circuit  or  fire  may 

occur  if  you  do  the  installation  work  yourself. 

•  Please observe the instructions stated in the installation manual during the process of installation. Improper installation 

may  cause  water  leakage,  electric shock  and  fire. 

•  A brazed,  welded,  or  mechanical  connection  shall  be  made  before  opening  the  valves  to  permit  refrigerant  to  flow 

between  the  refrigerating  system parts. A vacuum valve shall be provided to  evacuate the  interconnecting  pipe  and/ 

or  any  uncharged  refrigerating  system  part. 

•  Mechanical connectors used indoors shall comply with  ISO 14903. When mechanical connectors are reused indoors, 

sealing  parts  shall  be  renewed.  When  flared  joints  are  reused  indoors,  the  flare part  shall  be  re-fabricated. 

•  Refrigerant  tubing  shall  be  protected  or  enclosed  to  avoid  damage. 
•  Make  sure  that  the units  are  mounted  at  locations  which  are  able  to  provide full  support  to  the weight  of the units. 

If not,  the  units may  collapse  and  impose danger. 

•  Observe the rules  and regulations  of  the  electrical  installation  and  the  methods  described in  the  installation manual 

when  dealing  with  the  electrical  work.  Use  power  cables  approved  by  the  authorities  of  your  country. 

•  Be  sure  to  use  the  specified  wire  for  connecting  the  indoor  and  outdoor  units.  Please  ensure  that  the  connections 

are  tight  after  the  conductors  of  the  wire  are  inserted  into  the  terminals.  Improper  insertion  and  loose  contact  may 

cause  over-heating  and  fire. 

•  Please  use  the  specified  components  for  installation  work.  Otherwise,  the  units  may  collapse  or  water  leakage, 

electric shock  and  fire may  occur. 

•  Be  sure  to  use  the specified  piping  set  for  R32.  Otherwise,  this  may  result in broken  copper  pipes  or  faults. 
•  When installing  or  removing  an  air conditioner,  only  specified  refrigerant  (R32)  shall  be  allowed,  do  not  allow  air or 

moisture to remain in  the refrigeration cycle. Otherwise,  pressure in  the refrigeration cycle may  become abnormally 

high  so  that  a  rupture  may  be  caused. 

•  Be  sure  to  ventilate  fully  if  a  refrigerant  gas  leak  while  at  work.  If  the  refrigerant  gas  comes  into  contact  with  fire, 

a  poisonous  gas  may  occur.  Be  aware  that  refrigerants  may  not  contain  an  odour. 

•  After completion of installation  work,  check  to make sure that  there is  no refrigeration gas  leakage.  If the refrigerant 

gas  leaks  into  the room,  coming into  contact  with  fire  in  the  fan-driven  heater,  space heater,  etc.,  a poisonous  gas 

may  occur. 

•  Unauthorized  modifications  to  the  air  conditioner  may  be  dangerous.  If  a  breakdown  occurs  please  call  a  qualified 

air  conditioner  technician  or  electrician.  Improper  repairs  may  result  in  water leakage,  electric  shock  and  fire,  etc. 

,6 CAUTION 

•  A circuit  breaker  or  fuse must be  installed.  Without  a  circuit  breaker  or  fuse  the  danger  of  electric  shock  exists. 

The  external  switch  shall  be  incorporated  to  completely  disconnect  from  power  supply.  It  should  disconnect  all 

poles,  and  a  contact  separation  of  at  least  3mm  must  be  present. 

•  Do  not  install  the  unit  near  a  location  where  there  is  flammable  gas.  The  outdoor  unit  may  catch  �-

fire if  flammable  gas  leaks  around  it. 

\� 

•  Do  not  install  the  indoor  unit  in  a  machine  shop  or  kitchen  where  vapor  from  oil  or  its  mist  flows  to  the  indoor 

unit.  The  oil  will  deposit  on  the  heat  exchanger,  thereby  reducing  the  indoor  unit  performance  and  may  deform 

and in  the worst  case,  break  the  plastic  parts  of  the  indoor  unit. 

•  Please  ensure  smooth  flow  of  water when  installing  the  drain  hose. 
•  Piping  shall  be  suitable  supported  with  a  maximum  spacing  of  1 m  between  the  supports. 

,6 WARNING 

•  Do  not  use  means  to  accelerate  the  defrosting  process  or  to  clean,  other  than  those  recommended  by  the 

manufacturer. Any  unfit  method  or  using  incompatible  material  may  cause  product  damage,  burst  and  serious 

injury. 

•  The  appliance/pipe-work  shall  be  stored  in  a  well  ventilated  room  with  indoor  floor  area  larger  than  A

m

;,  [refer 

to Table 1]  and without any continuously operating ignition source. Keep  away from open flames,  any operating 

gas  appliances  or  any  operating  electric  heater.  Else,  it  may  explode  and cause injury  or  death. 

•  The  appliance/pipe-work  shall  be  installed,  and/or  operated  in  a  room  with  floor  area  larger  than  A

m

;,  [refer  to 

Table 1]  and  keep  away from  ignition  sources,  such  as heat/spark/open  flame  or hazardous  areas  such  as  gas 

appliances,  gas  cooking,  reticulated  gas supply  systems  or  electric  cooking  appliances,  etc. 

•  Do not pierce  or burn as the appliance/pipe-work is pressurized. Do not expose the appliance/pipe-work to heat, 

flame,  sparks,  or  other  sources  of  ignition.  Else,  it  may  explode  and  cause  injury  or  death. 

<IA0000:@> 

INS RAC-E50/60YHA (EN).indd  1 

The Choice  of  Mounting  Site 

(Please note the following  matters  and  obtain permission from customer before installation). 

,1',WARNING 

Names  of  Outdoor  Components 

• 

The Outdoor unit must be mounted at a location which can support 

No. 

Item 

Qty 

Dimension  of  Mounting  Stand 

of the Outdoor unit 

heavy  weight.  Otherwise,  noise  and  vibration  will  increase. 

Lt, 

CAUTION 

• 

Do  not expose the unit under direct sunshine  or rain.  Besides, 

ventilation  must  be good  and  clear  of  obstruction. 

• 

The air  blown out of the unit should not point directly to animals 

or plants. 

• 

The  clearances  of  the  unit  from  top,  left,  right  and  front  are 

specified  in  figure  below. At least 3  of the above sides  must  be 

open  air. 

• 

Be  sure  that  the hot  air  blown  out  of  the  unit  and  noise  do  not 

disturb the neighbourhood. 

• 

Do not install at a location where there is flammable gas, steam, 

oil  and  smoke. 

• 

The  location  must  be convenient  for  water  drainage. 

• 

Place the Outdoor unit and its connecting cord at least 1 m away 

from  the antenna or  signal line of  television,  radio or  telephone. 

This is  to  avoid  noise interference. 

• 

Do  not  install  outdoor  unit  facing  strong  wind  direction.  It  may 

damage the  fan  motor. 

•  Do  not install the outdoor unit  in a place where  small animals 

may  build  their  nests.  If  small  animal  goes  inside  the  unit  and 

touches the electrical parts, failure of the unit, smoke or fire may 

be  caused.  Request  your  customer  to  keep  the  surrounding  of 

the  unit  is  clean. 

G) 

® 

Bush 

� 

Drain  Pipe 

;s 

Bush 

(unit: mm) 

mounting  stand 

Figure showing  the  Installation  of Outdoor  Unit. 

&CAUTION 

•  This unit is chargeless up 30m pipe length. 

•  Installation  of  pipe  length  less  than  minimum  pipe  length 

requirement  (3 meters) may generate an abnormal sound. 

&, 

WARNING 

Table  1:  Minimum  Floor  area  of  the  room A

min 

(m') 

This  symbol  shows  that  this 

equipment  uses  a  flammable 

refrigerant. 

If  the  refrigerant  is  leaked, 

together  with  an external 

ignition  source,  there  is  a 

possibility  of  ignition. 

CAUTION 

This  symbol  shows  that  the 

Operation  Instructions  should 

be  read  carefully. 

�CAUTION 

This  symbol  shows  that  a 

service  personnel  should  be 

handling  this  equipment  with 

reference  to  the  Installation 

Manual. 

[Il] 

CAUTION 

This  symbol  shows  that  there 

is  information  included  in 

the  Operation  Manual  and/or 

Installation  Manual 

Lt,. 

WARNING 

BURST  HAZARD 

Do  not  allow  air,  etc.  to  get 

into refrigerant cycle  (piping) 

RISK  OF  EXPLOSION 

Compressor must be stopped 

before  removing  refrigerant 

pipes. 

All service valve must be fully 

closed  after  pumping  down 

operation. 

Outdoor 

Max  Piping 

Model 

Length 

(m) 

RAC-E50YHA 

30 

RAC-E60YHA 

30 

Be sure to 

completely 

seal any gap 

with putty. 

g  Jll 

13 

�-1 

"O 

�-gj

()iii 

Refrigerant  piping 

must  be  protected 

from  physical 

damage.  Install  a 

plastic  cover  or 

equivalent. 

c. 

·a 

-� 

*

above 700mm 

Max refrigerant 

Minimum  Floor  area  of  the  room 

charge  amount 

A

m

i

(m') 

(g) 

RAS-E**YHA  RAI-E**YHA  RAD-E**YHA 

1500 
1500 

2.15 
2.15 

as  wide  as 

possible 

1.44 

1.44 

1.44 

1.44 

i'.'.t.WARNING 

Flare connection only at outside 

of  building 

The indoor piping should 

be  insulated with the 

enclosed insulation 

pipe.  (If the insulator is 

insufficient,  please  use 

commercial products). 

•  The  difference  in  height 

between  the  indoor  and 

outdoor  unit  should  be

kept max 20m. 

•  The  connecting  pipe,

no  matter  big  or  small, 

should  all  be  insulated 

with  insulation pipe  and 

then  wrapped  with  vinyl 

tape.  (The  insulator  will 

deteriorate  if  it  is  not 

wrapped with tape). 

The connection of  insulated 

drain  hose. 

inner diameter 0  16mm 

� 

Please  use  insulated  drain 

hose  for  the  indoor  piping 

(commercial  product). 