1.2 Wall Penetration and Installation of Protection Pipe
1
Drill a ø65mm hole on wall
which is slightly tilted towards
the outdoor side.
2
Cut the protection pipe
according to the wall thickness
and pass through the wall
hole.
3
Empty gap in the sleeve of
protection pipe should be
completely sealed with putty
to avoid dripping of rain water
into the room.
3
5
4
6
2
1
1. Installation of Mounting Board, Wall Penetration and Installation of Protection
Pipe
• Carefully read through the procedures of proper installation
before starting installation work.
• The sales agent should inform customers regarding the
correct operation of installation.
Tools Needed For Installation Work
( mark is tool exclusive use for R410A) •
ª
·
Screwdriver
• Measuring Tape • Knife • Saw • Pipe Cutter • Hexagonal Wrench
K e y (
4 m m ) • P o w e r D r i l l ( ø 6 5 ~ ø 8 0 m m )
• Vacuum Pump • Pliers or Wrench • Torque Wrench
Vacuum Pump Adaptor Flare Tool Gas Leakage
Detector
Manifold
Valve
Charge
Hose
FOR SERVICE PERSONNEL ONLY
—
7
—
INDOOR UNIT / OUTDOOR UNIT
RAS-18SX8 / RAC-18SX8
RAS-25SX8 / RAC-25SX8
RAS-35SX8 / RAC-35SX8
HITACHI SPLIT UNIT AIR CONDITIONER
INSTALLATION MANUAL
• Read the safety precautions carefully before operating the unit.
• The contents of this section are vital to ensure safety. Please pay special attention to the following sign.
WARNING ...... Incorrect methods of installation may cause death or serious injury.
Make sure to connect earth line.
CAUTION ....... Improper installation may result in serious consequence.
This sign indicates prohibition.
Be sure that the unit operates in proper condition after installation. Explain to customer the proper operation and maintenance of the unit
as described in the user’s guide. Ask customers to keep this installation manual together with the instruction manual.
WARNING
• Please request your sales agent or quali
fi
ed technician to install your unit. Water leakage, short circuit or
fi
re may occur if you do the installation work
yourself.
• Please observe the installation stated in the installation manual during the process of installation. Improper installation may cause water leakage, electric
shock and
fi
re.
• Make sure that the units are mounted at locations which are able to provide full support to the weight of the units. If not, the units may collapse and
impose danger.
• Observe the rules and regulations of the electrical installation and the methods described in the installation manual when dealing with the electrical
work. Use cables which are approved of
fi
cial in your country. Be sure to use the speci
fi
ed circuit. A short circuit and
fi
re may occur due to the use of
low quality wire or improper work.
• Be sure to use the speci
fi
ed cables for connecting the indoor and outdoor units. Please ensure that the connections are tight after the conductors of
the wire are inserted into the terminals to prevent the external force is being applied to the connection section of the terminal base. Improper insertion
and loose contact may cause over-heating and
fi
re.
• Please use the speci
fi
ed components for installation work. Otherwise, the unit may collapse or water leakage, electric shock,
fi
re or stronger vibration
may occur.
• Be sure to use the speci
fi
ed piping set for R410A. Otherwise, this may result in broken copper pipes or faults.
• When installing or transferring an air conditioner to another location, make sure that air other than the speci
fi
ed refrigerant (R410A) does not enter the
refrigeration cycle. If other air should enter, the pressure level of the refrigeration cycle may increase abnormally which could result in a rupture and injury.
• Be sure to ventilate fully if a refrigerant gas leak while at work. If the refrigerant gas comes into contact with
fi
re, a poisonous gas may occur.
• After completion of installation work, check to make sure that there is no refrigeration gas leakage. If the refrigerant gas leaks into the room, coming
into contact with
fi
re in the fan-driven heater, space heater, etc., a poisonous gas may occur.
• Unauthorized modi
fi
cations to the air conditioner may be dangerous. If a breakdown occurs please call a quali
fi
ed air conditioner technician or electrician.
Improper repairs may result in water leakage, electric shock and
fi
re, etc.
• Be sure to connect the earth line from the power supply wire to the outdoor unit and between the outdoor and indoor unit. Do not
connect the earth line to the gas tube, water pipe, lighting rod or the earth line of the telephone unit. Improper earthing may cause
electric shocks.
• When
fi
nishing the refrigerant collection (pumping down), stop the compressor and then remove the coolant pipe. If you remove the refrigerant pipe
while the compressor is operating and the service valve is released, air is sucked and a pressure in the freezing cycle system will build up steeply,
causing an explosion or injury.
• When installing the unit, be sure to install the refrigerant pipe before starting the compressor.
If the refrigerant pipe is not installed and the compressor is operated with the service valve released, air is sucked and the pressure level of the
refrigeration cycle may increase abnormally which could result in a rupture and injury.
CAUTION
• A circuit breaker must be installed in the house distribution box for the direct connected power supply cables to the outdoor unit. In case of other
installations a main switch with a contact gap or more than 3mm has to be installed. Without a circuit breaker, the danger of electric shock exists.
• Do not install the unit near a location where there is
fl
ammable gas. The outdoor unit may catch
fi
re if
fl
ammable gas leaks
around it.
• Please ensure smooth
fl
ow of water when installing the drain hose. Improper installing may wet your furniture.
• An IEC approved power cord should be used. Power cord type: NYM.
INDOOR UNIT
THE CHOICE OF MOUNTING SITE
(Please note the following matters and obtain permission from customer before installation.)
WARNING
• The unit should be mounted at stable, non-vibratory location which
can provide full support to the unit.
CAUTION
• No nearby heat source and no obstruction near the air outlet is
allowed.
• The clearance distances from top, right and left are speci
fi
ed as
Û
in
fi
gure below.
• The location must be convenient for water drainage and pipe
connection with the outdoor unit.
• Do not install at a location where there is
fl
ammable gas, steam,
oil and smoke. There is a risk of
fi
re, explosion, deterioration of
resin and/or damage.
• To avoid interference from noise, please place the unit and its
remote controller at least 1m from the radio and television.
• To avoid any error in signal transmission from the remote controller,
please put the controller far away from high-frequency machines
and high-power wireless systems.
• Lighting
fi
xtures with electronic starters may shorten the reception
distance and may even interfere with the signal being received.
OUTDOOR UNIT
WARNING
• The outdoor unit must be mounted at a location which can support heavy
weight. Otherwise, noise and vibration will increase.
CAUTION
• Do not expose the unit under direct sunshine or rain. Besides, ventilation
must be good and clear of obstruction.
• The air blown out of the unit should not point directly to animals or
plants.
• The clearances of the unit from top, left, right and front are speci
fi
ed as
Û
in
fi
gure below. At least two sides must be clear for ventilation.
• Be sure that the hot air blown out of the unit and noise do not disturb the
neighbourhood.
• Place not exposed to strong wind
Particularly on the rooftop of a building, strong wind blows and the outdoor
unit may be damaged.
• Do not install at a location where there is
fl
ammable gas, steam, oil and
smoke.
• The location must be convenient for water drainage.
• Place the outdoor unit and its connecting cord at least 1m away from the
antenna or signal line of television, radio or telephone. This is to avoid
noise interference.
• Do not install the indoor unit in a place where small animals may build
their nests. If small animal goes inside the unit and touches the electrical
parts, failure of the unit, smoke or
fi
re may be caused. Request your
customer to keep the surrounding of the unit clean.
INDOOR UNIT
Direction of Piping
Piping con
fi
guration may be in six
different directions: direct rear piping,
left or right downward piping and left
or right sideways piping.
No.
Supplied Items
Qty
Items
8
&
9
are included in the
package of the outdoor unit.
SAFETY PRECAUTION
The indoor unit (air outlet) should be installed at least 1.5m away
from
fi
re alarm.
Figure showing the installation of Indoor and Outdoor Unit (For example: Ground installation)
Above 50mm
Be sure to com pletely seal
any gap with putty.
The space indicated by an
arrow
Û
is to guarantee
the performance of the
air conditioner. Install the
apparatus at the ample
space in order to carry out
the maintenance and repair
works.
Above 50mm
Above 50mm (Above 100mm when there is piping connection at the back of the outdoor unit)
Above 80mm
Above 50mm
give clearance as
wide as possible
When installing the indoor unit
above the curtain rail or curtain
box, allow dimensions not
affecting the air
fl
ow.
Maximum pipe length 20m
Above 200mm
Above 200mm
About 300mm
Must not bend
The indoor piping should be
insulated with the enclosed
insulation pipe.
Above 200mm
Above 50 mm when installed
on the ceiling of balcony
Above 100mm
Heating ef
fi
ciency will be
enhanced if the space below the
outdoor unit is closed so that
no air passes through.
(Procure the material locally.)
The refrigerating machine oil is easily affected
by moisture. Use caution to prevent water from
entering the cycle.
Connection of insulated drain hose
Please use insulated drain hose
for the indoor piping (commer cial
product).
Inner diameter
16mm
• The difference in height between the indoor and
outdoor unit should be kept below 10m.
• The connecting pipe, no matter big or small,
should all be insulated with insulation pipe and
then wrapped with vinyl tape. The insulator will
deteriorate if it is not wrapped with tape.
Length of Power Cable
Do not modify the power cable.
About 0.9m
About 1.6m
Condensed Water Disposal of Outdoor Unit
• There is holes on the base of outdoor unit for condensed water to exhaust.
• In order to
fl
ow condensed water to the drain, the unit is installed on a stand or a block so that
the unit is 100mm above the ground, join the drain pipe as shown in the
fi
gure. Cover the other
drain holes (2 places) with a bush. To install the bush, put it on the drain hole as shown in the
fi
gure and press the both sides of the bush to
fi
t into the hole.
• After installation, check whether the drain pipe and bush cling to the base
fi
rmly.
• Install the outdoor unit horizontally and make sure that condensate drains away.
•
When using in areas with cold weather
Especially when there are heavy snows in areas with cold weather, condensed water may
freeze on the base and result in bad drainage. In such areas,
please do not install the bush
and the drain pipe
. Also, make sure that the distance from the drain hole to the ground is
250mm or more.
8
Bush
9
Drain pipe
Outer diameter:
above 16mm
Above
100mm
Drain hole
Drain hole
8
Bush
Push Push
CAUTION
•
The drain hose can be installed from the left or right of the Indoor unit. When installing the indoor unit, the
mounting board must be
fi
xed horizontally or slightly tilted down towards the side of drain hose.
If it is tilted above the side of the drain hose, condensed water may over
fl
ow.
1.1 Direct Mounting On The Wall
• Please use hidden beams in the wall to hold the
mounting board.
• When it is dif
fi
cult to look for a stud, use an item such
as board anchor (commercial product).
• When using the mounting hole provided by the
apartment, cut it in such manner that the dimension of
the mounting anchor projecting from the wall is 15mm
or below.
Mounting board
Hole for pipe
Board anchor
Line
Weight
Screw at the positions near the upper and lower hooks where the indoor
unit is hung. Use more than 4 screws for
fi
xing.
Mark
Level
2
Screw for
mounting board
Drill Hole for Board Anchor
• While placing the mounting board
on the wall, embed the board
anchor in the wall.
• Slide down the mounting plate and
then
fi
x the mounting board with the
board anchor.
798mm
480mm
158mm
450mm
450mm
174mm 100 mm
20mm
81.5mm
ø65mm
42.5mm
External
dimension of
indoor unit
268mm
600mm
95mm
348mm
635mm
81.5mm
295mm
200mm
50mm
42mm
ø65mm
ø80mm
ø65mm
42.5mm
Drain hose
2~5mm
WALL
Putty
Sleeve of
protection
pipe
Protection
pipe
Putty
Indoor
Outdoor
2. Installation of the Indoor Unit
2.1 Preparation of Installation
Remove the front panel
• To remove front panel, please refer to “Removing and
Attaching the Front Panel” on page 13.
• Make sure to use both hands to attach and remove the front
panel.
Remove the lower cover
• Push the bottom inner part (
1
) of the lower cover to remove
the lower cover.
• To attach the lower cover, attach
2
fi
rst and then attach
1
by rotating it around
2
as the fulcrum.
Remove
Attach
Wiring connection
• Please refer to “Connection of Power Cord” on page 10.
Cutting lower cover bush
(Horizontal and downward piping)
• While installing the pipe from the right, left or bottom side,
use a knife to cut lower cover bush accordingly.
• Use the groove on the outer side if the pipe which is to be
installed from the left side, etc. is big.
Bush part
Groove on the
outer side
Groove on the inner side
Changing of drain hose
(Horizontally piping)
• Install and change the drain hose and drain cap when installing
the pipe horizontally as shown below.
• Remove the lower cover when installing and changing.
• Do not carry out horizontal piping for drain hose.
Drain cap
Drain hose
1
Remove the screw and
pull out the drain hose.
Drain hose screw
2
Insert drain cap up to the
location securely till the
cap stops.
Drain
cap
Drain hose
Drain hose screw
Use the plier to pull and
turn the drain cap for easy
removal.
Push the drain hose deeply
into the screw hole,
fi
x with
the removed screw during
step
1
.
CAUTION
•
Be sure to insert drain hose and drain cap
fi
rmly and
fi
x with screw
Insuf
fi
cient insert may result in water leakage.
Preparation of Pipe
Backward piping
1
Remove the auxiliary insulation material sheet which is
attached to the pipe insulation.
2
Referring to the mark on the rear side, form the pipe within
the wall hole range.
Wall hole range
Horizontally and downward piping from the right
1
Remove the auxiliary insulation material sheet which is
attached to the pipe insulation. (Keep the removed auxiliary
insulation material sheet because it will be reused after pipe
connection.)
2
Carry out refrigerating pipe forming.
Layout of horizontally piping from the right
3
Temporary join the refrigerating pipe, drain hose and
connecting cord with tape.
Place the starting point
of refrigerating pipe
bending within the wall
hole range.
Please bend at a small
radius to form an arc.
Pipe
Bottom cover
bush hole
Drain hose
CAUTION
• Transform the piping while holding down the lower portion
of pipe-support by hand.
If the starting point of refrigerating pipe bending is projected
from the wall hole range or if the bending radius is too large,
the indoor unit may be lifted from wall and this may cause
poor
fi
nishing.
Pipe support
Transform after
bending downward
36mm
41mm
〜
Installation after connection of refrigerating pipes
(Horizontal piping)
1
Remove the auxiliary insulation material sheet which is
attached to the pipe insulation. Connect the refrigerating pipe.
(Refer to “Pipe Connection” on page 9)
2
Cut the heat insulation sheet refrigerating pipe aligning to
the insulation sheet of the pipe and
fi
x them temporarily with
tape.
3
Cover the pipe connection with the auxiliary insulation sheet
which was removed earlier, with its split line on the top. Wrap
the tape without any gap. Tape must not be over tightened.
(Refer to “Heat insulation and Finishing of Piping” on page 11)
If there is gap or over-tightened, it may cause condensation.
Refrigerating
pipe
Pipe
Auxiliary insulation
sheet
Refrigerating pipe
insulation sheet
Refrigerating pipe
insulation sheet
Cut
Refrigerating
pipe
About 90mm
Temporarily
wrap with tape
Split line of the auxiliary
insulation sheet must
be positioned within this
range.
Pipe support
Auxiliary insulation
sheet
Place the
ending point of
refrigerating pipe
bending within
this range.
Pipe support
Refrigerating pipe
Center line of wall hole
Place the
refrigerating
pipe bending
within the wall
hole range
ø65 wall
hole range
Drain
hose
24mm
36~41mm
56.5mm
3
Temporary join the refrigerating pipe, drain hose and
connecting cord together with tape.
Temporary join the refrigerating pipe,
drain hose and connecting cord
together with tape.
4
Wrap the wall hole portion with tape.
Wrap with tape
Pipe
Connecting
cord
Drain hose
Pipe support
Refrigerating pipe
Center line of wall hole
Place the
refrigerating
pipe bending
within the wall
hole range
ø65 wall
hole range
Drain
hose
24mm
36~41mm
56.5mm
4
Form the refrigerating pipe according to the wall hole
position.
Especially in the case of horizontally backward piping,
follow the instruction below to carry out accurate forming.
Forming of refrigerating pipe for horizontally backward
piping
(1) Refer to the mark at the back, start bending the
refrigerating piping within wall hole range.
Connecting the refrigerating pipe at the back of the
indoor unit
• Form and set the refrigerating pipe and connecting cord.
If the starting point of refrigerating pipe bending is
projected from the wall hole range or if the bending
radius is too large, the indoor unit may be lifted from
wall and this may cause poor
fi
nishing.
2.2 Installation
Connecting the refrigerating pipe other than at the back
of the indoor unit
1
Insert the pipes through the wall hole.
2
Hang the upper part of the Indoor unit on the mounting
board.
3
Push the lower part of the indoor unit to the wall, hook
the projection on the lower part of the Indoor unit onto the
mounting board.
4
Cover the pipe connection with the auxiliary insulation sheet
which was removed earlier, with its split line on the top. Wrap
the tape without any gap. (Refer to “Heat insulation and
Finishing of Piping” on page 11)
If there is gap or over-tightened, it may cause condensation.
CAUTION
•
When using a polyester core, make sure to insert it only
after
fl
aring is carried out to avoid cutting dust from
getting inside.
Auxiliary insulation sheet
Place the starting point of
refrigerating pipe bending within
the wall hole range.
Please bend at a small
radius to form an arc.
(2) When forming, bend the refrigerating pipe with the
smallest radius.
Refrigerating
pipe
Center line of
wall hole
ø65 wall hole
range
Drain
hose
Refrigerating
pipe
5
Form the connecting cord and refrigerating pipe and put
them in the space on the lower side of the rear surface
of the indoor unit. Put the binding band
0
on the hook
located on the rear surface to
fi
x it.
6
Join refrigerating pipe, connecting cord and drain hose
temporarily with tape and wrap the wall hole portion with
tape.
Be sure to cut the extra binding band.
(Otherwise, it may result in abnormal noise or dewfall.)
Hook
0
Binding band
Wrap with tape
Binding band can be
installed to whichever
side of the installation
points. However, it is
recommended to attach it
on the right side viewing
from the rear.
Match the end of the refrigerating pipes with the
locations marked with “
4
” symbol.
Insert polyester core (commercial product)
into the large diameter pipe.
Below 5mm
1.00m
Please bend at a small radius to form an arc. (Pipe can be bent
with a small radius without being crushed if polyester core is used.)
Projection of the indoor unit
1
Mounting board
1
Mounting board
Protection pipe
Refrigerating pipe
Connecting cord
Drain hose
1
2
3
OUTDOOR UNIT
Small
diameter
Connecting the refrigerating pipe at the back of the
indoor unit
1
Remove the auxiliary
insulation material sheet
which is attached to the
pipe insulation. (Keep
the removed auxiliary
insulation material sheet
because it will be reused
after pipe connection.)
2
Hang the indoor unit on the mounting board.
3
Place the cushion under the right rear surface of the indoor
unit to lift the lower side of the unit by approximately 15cm.
4
Connect the refrigerating pipe. (Refer to “Pipe Connection”
on page 9)
5
Cover the pipe connection with the auxiliary insulation sheet
which was removed earlier, with its split line on the top.
Wrap the tape without any gap. (Refer to “Installation after
connection of refrigerating pipes (Horizontal piping)” on page
5, step
3
)
6
Insert the drain hose into the wall hole.
7
Connect the connecting cord. (Refer to “Connection of Power
Cord” on page 10).
8
Form connecting cord and refrigerating pipe and put them in
the space on the lower side of the rear surface of the indoor
unit.
9
Remove the temporary stand and hook the projection on the
lower part of the Indoor unit onto the mounting board.
CAUTION
•
Do not over tighten vinyl tape on pipe heat insulation
sheet
Do not over tighten to avoid loss of heat insulating effect
and dew condensation.
•
Pull the lower part of the indoor unit towards you
and con
fi
rm that the tab of the indoor unit is
fi
t in the
installation plate
If the tab is not
fi
tted in securely, vibration of the indoor unit
becomes stronger.
Auxiliary insulation
sheet
Auxiliary insulation
sheet
Refrigerating pipe
Connecting cord
Connecting cord
Connection part
Protection pipe
Drain hose
Pull this to the front during
the connection of refrigerating
pipe to ease task.
CAUTION
•
During drainage work, install the drain pipe to ensure
smooth drainage. Make sure to carry out drainage
check.
Careless work may result in water leakage.
•
Make sure that there is no problem as shown in the
fi
gures on page 8.
Such problems may cause clogged drain and could result
in water leakage.
•
Drain hose must be at a slope of at least 1/25.
•
When inserting the drain hose into the drain pipe for
embedded piping, etc., do not cut the drain hose in the
middle.
This may lead to poorer heat insulating performance of the
drain hose and could result in water leakage.
•
Do not lead the drain hose to a place where corrosive
gas (sulfur, ammonia, etc.) is generated such as septic
tank.
Corrosive gas may
fl
ow into the indoor unit through the drain
hose, and could result in corrosion on the copper pipe and
odor in the room.
3. Drainage Check
After the indoor unit is installed, please ensure the smooth
fl
ow of condensed water of the indoor unit during installation.
(Careless work may result in water leakage.)
How to remove the indoor unit
• Push the [PUSH] section at the bottom of the indoor unit
from the outside, the claws are released from the mounting
board. (2 places on the left and right)
• If the bottom of the indoor unit cannot be pushed, remove
the bottom part of the front cover and insert a screwdriver
into the hole for removal of indoor unit as shown in the
fi
gure. Then, push the claws upwards while holding down
the upper part of the hole
1
and pull the indoor unit towards
you
2
. When horizontal piping is used, be careful not to
damage the pipe and connecting cord with the tip of the
screwdriver during this operation.
• Please refer to “Removing and Attaching the Front Cover”
on page 14 to remove the bottom part of the front cover.
Screwdriver
Hole for removal
Hold with hand
Hole for removal
Claw
Mounting board
1
2
Bending
upwards
Condensed
water pond
Ditch
Condensed
water pond
• Please mount the outdoor unit on stable ground to
prevent vibration and increase of noise level.
• Decide the location for piping after sorting out the
different types of pipe available.
• When removing side cover, please pull the handle
after undoing the hook by pulling it downward.
Reinstall the side cover in reverse order of the
removal.
Please face this side (suction side)
of the unit to the wall.
Please remove side cover
when connecting the piping
and connecting cord.
Pull
downward
In snowy region, install a snow guard and elevated stand
to ensure the air
fl
ow for better heating ef
fi
ciency.
In other regions, it is recommended to install a tent for
shade.
Elevated stand
Tent
Fixed leg dimension of outdoor unit
57
500
12
39
125
330
310
10
(10)
Fixed leg
Unit: mm
CAUTION
•
Do not touch the suction port, bottom surface
or aluminium
fi
n of the outdoor unit
Failure to do so may cause an injury.
Installation information
• Be sure to perform the cleaning unit operation check.
•
Unlike conventional types, this model has no grille on its top surface.
Large diameter
About 0.45m
WARNING
•
Protection pipe (commercial product) must be used
Be sure that the wire is not in contact with any metal in the
wall. Please use the protection pipe as wire passing through
the hollow part of the wall to prevent damaged by mouse,
possibility of short circuit or
fi
re.
•
Completely seal with putty
High humidity air inside the wall or the outdoor may go in to
the room and could result in dripping of dew. It could also
cause smell or odor present outdoor and inside the wall
spreading into the room.
Projection
of the
indoor unit
Fixing
tab
Cushion
About 15cm
Horizontally
backward
Bush part
CAUTION
Be sure that the drain hose is loosely connected
bend or proper condition like left
fi
gure.
CAUTION
You are free to choose the side (left or right) for
the installation of drain hose. Please ensure the
smooth
fl
ow of condensed water of the indoor unit
during installation. (Careless may result in water
leakage.)
—
3
—
—
1
—
—
2
—
—
5
—
—
6
—
—
4
—
—
8
—
Drain hose
For outdoor unit installation, allow at least
2 sides of space around the unit to ensure
ventilation
fl
ue.