1.2  Wall Penetration and Installation of Protection Pipe

1

 Drill a ø65mm hole on wall 

which is slightly tilted towards 
the outdoor side.

2

 Cut the protection pipe 

according to the wall thickness 
and pass through the wall 
hole.

3

 Empty gap in the sleeve of 

protection pipe should be 
completely sealed with putty 
to avoid dripping of rain water 
into the room.

3

5

4

6

2

1

1. Installation of Mounting Board, Wall Penetration and Installation of Protection

Pipe

• Carefully read through the procedures of proper installation

before starting installation work.

• The sales agent should inform customers regarding the

correct operation of installation.

Tools Needed For Installation Work

(  mark is tool exclusive use for R410A)  •  

ª

 

·

 Screwdriver 

• Measuring Tape • Knife • Saw • Pipe Cutter • Hexagonal Wrench 
K e y   (

  4 m m )   •   P o w e r   D r i l l   ( ø 6 5 ~ ø 8 0 m m ) 

• Vacuum Pump • Pliers or Wrench • Torque Wrench

 Vacuum Pump Adaptor   Flare Tool   Gas Leakage 

Detector  

Manifold 

Valve  

Charge 

Hose

FOR SERVICE PERSONNEL ONLY

 7 

INDOOR UNIT / OUTDOOR UNIT

RAS-18SX8 / RAC-18SX8
RAS-25SX8 / RAC-25SX8
RAS-35SX8 / RAC-35SX8

HITACHI SPLIT UNIT AIR CONDITIONER

INSTALLATION MANUAL

• Read the safety precautions carefully before operating the unit.
• The contents of this section are vital to ensure safety. Please pay special attention to the following sign.

 WARNING ...... Incorrect methods of installation may cause death or serious injury. 

  Make sure to connect earth line.

 CAUTION ....... Improper installation may result in serious consequence. 

  This sign indicates prohibition.

Be sure that the unit operates in proper condition after installation. Explain to customer the proper operation and maintenance of the unit 
as described in the user’s guide. Ask customers to keep this installation manual together with the instruction manual.

 WARNING

• Please request your sales agent or quali

fi

 ed technician to install your unit. Water leakage, short circuit or 

fi

 re may occur if you do the installation work

yourself.

•  Please observe the installation stated in the installation manual during the process of installation. Improper installation may cause water leakage, electric 

shock and 

fi

 re.

•  Make sure that the units are mounted at locations which are able to provide full support to the weight of the units. If not, the units may collapse and

impose danger.

•  Observe the rules and regulations of the electrical installation and the methods described in the installation manual when dealing with the electrical

work. Use cables which are approved of

fi

 cial in your country. Be sure to use the speci

fi

 ed circuit. A short circuit and 

fi

 re may occur due to the use of

low quality wire or improper work.

•  Be sure to use the speci

fi

 ed cables for connecting the indoor and outdoor units. Please ensure that the connections are tight after the conductors of

the wire are inserted into the terminals to prevent the external force is being applied to the connection section of the terminal base. Improper insertion
and loose contact may cause over-heating and 

fi

 re.

•  Please use the speci

fi

 ed components for installation work. Otherwise, the unit may collapse or water leakage, electric shock, 

fi

 re or stronger vibration

may occur.

•  Be sure to use the speci

fi

 ed piping set for R410A. Otherwise, this may result in broken copper pipes or faults.

•  When installing or transferring an air conditioner to another location, make sure that air other than the speci

fi

 ed refrigerant (R410A) does not enter the

refrigeration cycle. If other air should enter, the pressure level of the refrigeration cycle may increase abnormally which could result in a rupture and injury.

•  Be sure to ventilate fully if a refrigerant gas leak while at work. If the refrigerant gas comes into contact with 

fi

 re, a poisonous gas may occur.

•  After completion of installation work, check to make sure that there is no refrigeration gas leakage. If the refrigerant gas leaks into the room, coming

into contact with 

fi

 re in the fan-driven heater, space heater, etc., a poisonous gas may occur.

•  Unauthorized modi

fi

 cations to the air conditioner may be dangerous. If a breakdown occurs please call a quali

fi

 ed air conditioner technician or electrician. 

Improper repairs may result in water leakage, electric shock and 

fi

 re, etc.

•  Be sure to connect the earth line from the power supply wire to the outdoor unit and between the outdoor and indoor unit. Do not

connect the earth line to the gas tube, water pipe, lighting rod or the earth line of the telephone unit. Improper earthing may cause
electric shocks.

•  When 

fi

 nishing the refrigerant collection (pumping down), stop the compressor and then remove the coolant pipe. If you remove the refrigerant pipe

while the compressor is operating and the service valve is released, air is sucked and a pressure in the freezing cycle system will build up steeply,
causing an explosion or injury.

•  When installing the unit, be sure to install the refrigerant pipe before starting the compressor.

If the refrigerant pipe is not installed and the compressor is operated with the service valve released, air is sucked and the pressure level of the
refrigeration cycle may increase abnormally which could result in a rupture and injury.

 CAUTION

• A circuit breaker must be installed in the house distribution box for the direct connected power supply cables to the outdoor unit. In case of other

installations a main switch with a contact gap or more than 3mm has to be installed. Without a circuit breaker, the danger of electric shock exists.

• Do not install the unit near a location where there is 

fl

 ammable gas. The outdoor unit may catch 

fi

 re if 

fl

 ammable gas leaks

around it.

• Please ensure smooth 

fl

 ow of water when installing the drain hose. Improper installing may wet your furniture.

• An IEC approved power cord should be used. Power cord type: NYM.

INDOOR UNIT

THE CHOICE OF MOUNTING SITE

  (Please note the following matters and obtain permission from customer before installation.)

 WARNING

• The unit should be mounted at stable, non-vibratory location which 

can provide full support to the unit.

 CAUTION

• No nearby heat source and no obstruction near the air outlet is

allowed.

• The clearance distances from top, right and left are speci

fi

 ed as

Û

 in 

fi

 gure below.

• The location must be convenient for water drainage and pipe

connection with the outdoor unit.

• Do not install at a location where there is 

fl

 ammable gas, steam,

oil and smoke. There is a risk of 

fi

 re, explosion, deterioration of

resin and/or damage.

• To avoid interference from noise, please place the unit and its

remote controller at least 1m from the radio and television.

• To avoid any error in signal transmission from the remote controller, 

please put the controller far away from high-frequency machines
and high-power wireless systems.

• Lighting 

fi

 xtures with electronic starters may shorten the reception 

distance and may even interfere with the signal being received.

OUTDOOR UNIT

 WARNING

• The outdoor unit must be mounted at a location which can support heavy 

weight. Otherwise, noise and vibration will increase.

 CAUTION

• Do not expose the unit under direct sunshine or rain. Besides, ventilation 

must be good and clear of obstruction.

• The air blown out of the unit should not point directly to animals or

plants.

• The clearances of the unit from top, left, right and front are speci

fi

 ed as

Û

 in 

fi

 gure below. At least two sides must be clear for ventilation.

• Be sure that the hot air blown out of the unit and noise do not disturb the

neighbourhood.

• Place not exposed to strong wind

Particularly on the rooftop of a building, strong wind blows and the outdoor
unit may be damaged.

• Do not install at a location where there is 

fl

 ammable gas, steam, oil and

smoke.

• The location must be convenient for water drainage.
• Place the outdoor unit and its connecting cord at least 1m away from the 

antenna or signal line of television, radio or telephone. This is to avoid
noise interference.

• Do not install the indoor unit in a place where small animals may build

their nests. If small animal goes inside the unit and touches the electrical 
parts, failure of the unit, smoke or 

fi

 re may be caused. Request your

customer to keep the surrounding of the unit clean.

INDOOR UNIT

Direction of Piping

Piping con

fi

 guration may be in six 

different directions: direct rear piping, 
left or right downward piping and left 
or right sideways piping.

 No. 

Supplied Items 

Qty

 Items 

8

 & 

9

 are included in the 

package of the outdoor unit.

SAFETY PRECAUTION

The indoor unit (air outlet) should be installed at least 1.5m away 
from 

fi

 re alarm.

Figure showing the installation of Indoor and Outdoor Unit (For example: Ground installation)

Above 50mm

Be sure to com pletely seal 
any gap with putty.

The space indicated by an 
arrow 

Û

  is to guarantee 

the performance of the 
air conditioner. Install the 
apparatus at the ample 
space in order to carry out 
the maintenance and repair 
works.

Above 50mm

Above 50mm (Above 100mm when there is piping connection at the back of the outdoor unit)

Above 80mm

 Above 50mm

  give  clearance  as     

wide as possible

When installing the indoor unit 
above the curtain rail or curtain 
box, allow dimensions not 
affecting the air

fl

 ow.

Maximum pipe length 20m

Above 200mm

 Above 200mm

About 300mm

Must not bend

The indoor piping should be 
insulated with the enclosed 
insulation pipe.

Above 200mm

Above 50 mm when installed 
on the ceiling of balcony

Above 100mm

Heating ef

fi

 ciency will be 

enhanced if the space below the 
outdoor unit is closed so that 
no air passes through.

(Procure the material locally.)

The refrigerating machine oil is easily affected 
by moisture. Use caution to prevent water from 
entering the cycle.

Connection of insulated drain hose

Please use insulated drain hose 
for the indoor piping (commer cial 
product).

Inner diameter 

16mm

•  The difference in height between the indoor and 

outdoor unit should be kept below 10m.

• The connecting pipe, no matter big or small,

should all be insulated with insulation pipe and
then wrapped with vinyl tape. The insulator will
deteriorate if it is not wrapped with tape.

Length of Power Cable

Do not modify the power cable.

About 0.9m

About 1.6m

Condensed Water Disposal of Outdoor Unit

• There is holes on the base of outdoor unit for condensed water to exhaust.
• In order to 

fl

 ow condensed water to the drain, the unit is installed on a stand or a block so that

the unit is 100mm above the ground, join the drain pipe as shown in the 

fi

 gure. Cover the other

drain holes (2 places) with a bush. To install the bush, put it on the drain hole as shown in the

fi

 gure and press the both sides of the bush to 

fi

 t into the hole.

• After installation, check whether the drain pipe and bush cling to the base 

fi

 rmly.

• Install the outdoor unit horizontally and make sure that condensate drains away.

When using in areas with cold weather

Especially when there are heavy snows in areas with cold weather, condensed water may
freeze on the base and result in bad drainage. In such areas, 

please do not install the bush

and the drain pipe

. Also, make sure that the distance from the drain hole to the ground is

250mm or more.

8

 Bush

9

 Drain pipe

Outer diameter: 
above 16mm

Above 
100mm

Drain hole

Drain hole

8

 Bush

Push     Push

 CAUTION

The drain hose can be installed from the left or right of the Indoor unit. When installing the indoor unit, the
mounting board must be 

fi

 xed horizontally or slightly tilted down towards the side of drain hose.

If it is tilted above the side of the drain hose, condensed water may over

fl

 ow.

1.1  Direct Mounting On The Wall

• Please use hidden beams in the wall to hold the

mounting board.

• When it is dif

fi

 cult to look for a stud, use an item such

as board anchor (commercial product).

• When using the mounting hole provided by the

apartment, cut it in such manner that the dimension of 
the mounting anchor projecting from the wall is 15mm 
or below.

Mounting board

Hole for pipe

Board anchor

Line

Weight

Screw at the positions near the upper and lower hooks where the indoor 
unit is hung. Use more than 4 screws for 

fi

 xing.

Mark

Level

2

 Screw for 

mounting board

Drill Hole for Board Anchor

• While placing the mounting board

on the wall, embed the board
anchor in the wall.

• Slide down the mounting plate and

then 

fi

 x the mounting board with the

board anchor.

798mm
480mm

158mm

450mm

450mm

        174mm          100 mm

20mm

81.5mm

ø65mm

42.5mm

External 
dimension of 
indoor unit

268mm

600mm

95mm

348mm
635mm

81.5mm

295mm

200mm

50mm

42mm

ø65mm

ø80mm

ø65mm

42.5mm

Drain hose

2~5mm

WALL

Putty

Sleeve of 
protection 
pipe

Protection 
pipe

Putty

Indoor

Outdoor

2. Installation of the Indoor Unit

2.1  Preparation of Installation

   Remove the front panel

• To remove front panel, please refer to “Removing and

Attaching the Front Panel” on page 13.

• Make sure to use both hands to attach and remove the front

panel.

   Remove the lower cover

• Push the bottom inner part (

1

) of the lower cover to remove 

the lower cover.

• To attach the lower cover, attach 

2

 

fi

 rst and then attach 

1

by rotating it around 

2

 as the fulcrum.

Remove

Attach

   Wiring connection

• Please refer to “Connection of Power Cord” on page 10.

   Cutting lower cover bush
   

(Horizontal and downward piping)

• While installing the pipe from the right, left or bottom side,

use a knife to cut lower cover bush accordingly.

• Use the groove on the outer side if the pipe which is to be

installed from the left side, etc. is big.

Bush part

Groove on the 
outer side

Groove on the inner side

   Changing of drain hose

 

   

(Horizontally piping)

• Install and change the drain hose and drain cap when installing

the pipe horizontally as shown below.

• Remove the lower cover when installing and changing.
• Do not carry out horizontal piping for drain hose.

Drain cap

Drain hose

1

 Remove the screw and 

pull out the drain hose.

Drain hose screw

2

  Insert drain cap up to the 

location securely till the 
cap stops.

Drain 
cap

Drain hose

Drain hose screw

Use the plier to pull and 
turn  the drain cap for easy 
removal.

Push the drain hose deeply 
into the screw hole, 

fi

 x with 

the removed screw during 
step 

1

 CAUTION

Be sure to insert drain hose and drain cap 

fi

 rmly and

fi

 x with screw

Insuf

fi

 cient insert may result in water leakage.

   Preparation of Pipe

Backward piping

1

  Remove the auxiliary insulation material sheet which is 

attached to the pipe insulation. 

2

  Referring to the mark on the rear side, form the pipe within 

the wall hole range. 

Wall hole range

Horizontally and downward piping from the right

1

  Remove the auxiliary insulation material sheet which is 

attached to the pipe insulation. (Keep the removed auxiliary 
insulation material sheet because it will be reused after pipe 
connection.) 

2

  Carry out refrigerating pipe forming. 

Layout of horizontally piping from the right

3

  Temporary join the refrigerating pipe, drain hose and 

connecting cord with tape. 

Place the starting point 
of refrigerating pipe 
bending within the wall 
hole range.

Please bend at a small
radius to form an arc.

Pipe

Bottom cover
bush hole

Drain hose

 CAUTION

• Transform the piping while holding down the lower portion

of pipe-support by hand.

If the starting point of refrigerating pipe bending is projected 
from the wall hole range or if the bending radius is too large, 
the indoor unit may be lifted from wall and this may cause 
poor 

fi

 nishing.

Pipe support

Transform after
bending downward

36mm

41mm

Installation after connection of refrigerating pipes 
(Horizontal piping)

1

  Remove the auxiliary insulation material sheet which is 

attached to the pipe insulation. Connect the refrigerating pipe. 
(Refer to “Pipe Connection” on page 9) 

2

  Cut the heat insulation sheet refrigerating pipe aligning to 

the insulation sheet of the pipe and 

fi

 x them temporarily with 

tape. 

3

  Cover the pipe connection with the auxiliary insulation sheet 

which was removed earlier, with its split line on the top. Wrap 
the tape without any gap. Tape must not be over tightened. 
(Refer to “Heat insulation and Finishing of Piping” on page 11)

 

If there is gap or over-tightened, it may cause condensation. 

Refrigerating 
pipe

Pipe

Auxiliary insulation 
sheet

Refrigerating pipe 
insulation sheet

Refrigerating pipe
insulation sheet

Cut

Refrigerating 
pipe

About 90mm

Temporarily 
wrap with tape

Split line of the auxiliary 
insulation sheet must 
be positioned within this 
range.

Pipe support

Auxiliary insulation 
sheet

Place the 
ending point of 
refrigerating pipe 
bending within 
this range.

Pipe support

Refrigerating pipe

Center line of wall hole

Place the 
refrigerating 
pipe bending 
within the wall 
hole range

ø65 wall 
hole range

Drain 
hose

24mm

36~41mm

56.5mm

3

  Temporary join the refrigerating pipe, drain hose and 

connecting cord together with tape. 

Temporary join the refrigerating pipe, 
drain hose and connecting cord 
together with tape.

4

  Wrap the wall hole portion with tape. 

Wrap with tape

Pipe

Connecting 
cord

Drain hose

Pipe support

Refrigerating pipe

Center line of wall hole

Place the 
refrigerating 
pipe bending 
within the wall 
hole range

ø65 wall 
hole range

Drain 
hose

24mm

36~41mm

56.5mm

4

  Form the refrigerating pipe according to the wall hole 

position.
Especially in the case of horizontally backward piping, 
follow the instruction below to carry out accurate forming.

Forming of refrigerating pipe for horizontally backward 
piping

(1) Refer to the mark at the back, start bending the 

refrigerating piping within wall hole range.

Connecting the refrigerating pipe at the back of the 
indoor unit

• Form and set the refrigerating pipe and connecting cord.

If the starting point of refrigerating pipe bending is 
projected from the wall hole range or if the bending 
radius is too large, the indoor unit may be lifted from 
wall and this may cause poor 

fi

 nishing.

2.2 Installation

Connecting the refrigerating pipe other than at the back 
of the indoor unit

1

  Insert the pipes through the wall hole.

2

  Hang the upper part of the Indoor unit on the mounting 

board.

3

  Push the lower part of the indoor unit to the wall, hook 

the projection on the lower part of the Indoor unit onto the 
mounting board.

4

  Cover the pipe connection with the auxiliary insulation sheet 

which was removed earlier, with its split line on the top. Wrap 
the tape without any gap. (Refer to “Heat insulation and 
Finishing of Piping” on page 11)
If there is gap or over-tightened, it may cause condensation. 

 CAUTION

When using a polyester core, make sure to insert it only 
after 

fl

 aring is carried out to avoid cutting dust from

getting inside.

Auxiliary insulation sheet

Place the starting point of 
refrigerating pipe bending within 
the wall hole range.

Please bend at a small
radius to form an arc.

(2) When forming, bend the refrigerating pipe with the 

smallest radius.

Refrigerating 
pipe

Center line of 
wall hole

ø65 wall hole 
range

Drain 
hose

Refrigerating 
pipe

5

  Form the connecting cord and refrigerating pipe and put 

them in the space on the lower side of the rear surface 
of the indoor unit. Put the binding band 

0

 on the hook 

located on the rear surface to 

fi

 x it.

6

  Join refrigerating pipe, connecting cord and drain hose 

temporarily with tape and wrap the wall hole portion with 
tape.

Be sure to cut the extra binding band.

(Otherwise, it may result in abnormal noise or dewfall.)

Hook

0

 Binding band

Wrap with tape

Binding band can be 
installed to whichever 
side of the installation 
points. However, it is 
recommended to attach it 
on the right side viewing 
from the rear.

Match the end of the refrigerating pipes with the 
locations marked with “

4

” symbol.

Insert polyester core (commercial product) 
into the large diameter pipe.

Below 5mm

1.00m

Please bend at a small radius to form an arc. (Pipe can be bent 
with a small radius without being crushed if polyester core is used.)

Projection of the indoor unit

1

 Mounting board

1

 Mounting board

Protection pipe

Refrigerating pipe

Connecting cord

Drain hose

1

2

3

OUTDOOR UNIT

Small

diameter

Connecting the refrigerating pipe at the back of the 
indoor unit

1

  Remove the auxiliary 

insulation material sheet 
which is attached to the 
pipe insulation. (Keep 
the removed auxiliary 
insulation material sheet 
because it will be reused 
after pipe connection.) 

2

  Hang the indoor unit on the mounting board. 

3

  Place the cushion under the right rear surface of the indoor 

unit to lift the lower side of the unit by approximately 15cm. 

4

  Connect the refrigerating pipe. (Refer to “Pipe Connection” 

on page 9) 

5

  Cover the pipe connection with the auxiliary insulation sheet 

which was removed earlier, with its split line on the top. 
Wrap the tape without any gap. (Refer to “Installation after 
connection of refrigerating pipes (Horizontal piping)” on page 
5, step 

3

6

  Insert the drain hose into the wall hole. 

7

  Connect the connecting cord. (Refer to “Connection of Power 

Cord” on page 10). 

8

  Form connecting cord and refrigerating pipe and put them in 

the space on the lower side of the rear surface of the indoor 
unit. 

9

  Remove the temporary stand and hook the projection on the 

lower part of the Indoor unit onto the mounting board. 

 CAUTION

Do not over tighten vinyl tape on pipe heat insulation
sheet

Do not over tighten to avoid loss of heat insulating effect
and dew condensation.

Pull the lower part of the indoor unit towards you
and con

fi

 rm that the tab of the indoor unit is 

fi

 t in the

installation plate

If the tab is not 

fi

 tted in securely, vibration of the indoor unit

becomes stronger.

Auxiliary insulation 
sheet

Auxiliary insulation 
sheet

Refrigerating pipe

Connecting cord

Connecting cord

Connection part

Protection pipe

Drain hose

Pull this to the front during 
the connection of refrigerating 
pipe to ease task.

 CAUTION

During drainage work, install the drain pipe to ensure
smooth drainage. Make sure to carry out drainage
check.

Careless work may result in water leakage.

Make sure that there is no problem as shown in the

fi

 gures on page 8.

Such problems may cause clogged drain and could result
in water leakage.

Drain hose must be at a slope of at least 1/25.

When inserting the drain hose into the drain pipe for
embedded piping, etc., do not cut the drain hose in the
middle.

This may lead to poorer heat insulating performance of the
drain hose and could result in water leakage.

Do not lead the drain hose to a place where corrosive
gas (sulfur, ammonia, etc.) is generated such as septic
tank.

Corrosive gas may 

fl

 ow into the indoor unit through the drain 

hose, and could result in corrosion on the copper pipe and
odor in the room.

3. Drainage Check

After the indoor unit is installed, please ensure the smooth 

fl

 ow of condensed water of the indoor unit during installation. 

(Careless work may result in water leakage.)

How to remove the indoor unit

• Push the [PUSH] section at the bottom of the indoor unit

from the outside, the claws are released from the mounting
board. (2 places on the left and right)

• If the bottom of the indoor unit cannot be pushed, remove

the bottom part of the front cover and insert a screwdriver
into the hole for removal of indoor unit as shown in the

fi

 gure. Then, push the claws upwards while holding down

the upper part of the hole 

1

 and pull the indoor unit towards 

you 

2

. When horizontal piping is used, be careful not to

damage the pipe and connecting cord  with the tip of the
screwdriver during this operation.

• Please refer to “Removing and Attaching the Front Cover”

on page 14 to remove the bottom part of the front cover.

Screwdriver

Hole for removal

Hold with hand

Hole for removal

Claw

Mounting board

1

2

Bending 
upwards

Condensed
water pond

Ditch

Condensed
water pond

• Please mount the outdoor unit on stable ground to

prevent vibration and increase of noise level.

• Decide the location for piping after sorting out the

different types of pipe available.

• When removing side cover, please pull the handle

after undoing the hook by pulling it downward.
Reinstall the side cover in reverse order of the
removal.

Please face this side (suction side) 
of the unit to the wall.

Please remove side cover 
when connecting the piping 
and connecting cord.

Pull 
downward

In snowy region, install a snow guard and elevated stand 
to ensure the air

fl

 ow for better heating ef

fi

 ciency.

In other regions, it is recommended to install a tent for 
shade.

Elevated stand

Tent

Fixed leg dimension of outdoor unit

57

500

12

39

125

330

310

10

(10)

Fixed leg

Unit: mm

 CAUTION

Do not touch the suction port, bottom surface 
or aluminium 

fi

 n of the outdoor unit

Failure to do so may cause an injury.

Installation information 

• Be sure to perform the cleaning unit operation check.
• 

Unlike conventional types, this model has no grille on its top surface.

Large diameter

About 0.45m

 WARNING

Protection pipe (commercial product) must be used

Be sure that the wire is not in contact with any metal in the
wall. Please use the protection pipe as wire passing through 
the hollow part of the wall to prevent damaged by mouse,
possibility of short circuit or 

fi

 re.

Completely seal with putty

High humidity air inside the wall or the outdoor may go in to
the room and could result in dripping of dew. It could also
cause smell or odor present outdoor and inside the wall
spreading into the room.

Projection 
of the 
indoor unit

Fixing
tab

Cushion

About 15cm

Horizontally 
backward

Bush part

 CAUTION

Be sure that the drain hose is loosely connected 
bend or proper condition like left 

fi

 gure.

 CAUTION

You are free to choose the side (left or right) for 
the installation of drain hose. Please ensure the 
smooth 

fl

 ow of condensed water of the indoor unit 

during installation. (Careless may result in water 
leakage.)

 3 

 1 

 2 

 5 

 6 

 4 

 8 

Drain hose

For outdoor unit installation, allow at least 
2 sides of space around the unit to ensure 
ventilation 

fl

 ue.