Notes:
Notes:
Indoor unit
15″
1′
60
6℃
2℃
Lo
Lo
OFF
ON
PWSFTC
1″
Lo
Lo
S
0.
5h
r
1h
r
9h
r
Cooling, sleep
Sleep key
Set to 9 hours
Operation
monitor lamp
Remote control
"SLEEP" lit
Timer lamp lit
HI
MED
LOW
SILENT
Sleep
See "Basic mode."
Outdoor unit
Upper and
lower louvers
Shut
Horizontal
Facing
downwards
Compressor speed
Compressor speed
Compressor speed
(1) Setting the sleep key will limit the compressor's maximum speed to CSZMAX and the indoor unit to
"sleep LOW" (FCSOY).
(2) Changing fan speed mode will not change the indoor unit speed.
(3) Changing operation mode during sleep operation will clear the temperature setting, time
and all other settings, and make a fresh start.
(4) Stopping the product midway will retain the temperature setting which was effective at the time of
stoppage and continues to count the time.
(5) Changing the time setting midway will clear the temperature setting, time and all other settings,
and make a fresh start.
(6) Canceling with the cancel key and sleep key will clear everything.
(7)
As-desired "powerful" operation
Remote control
"POWERFUL" lit
Temperature setting
(1) Pressing the as-desired button will reduce the temperature setting by PWSFTC.
(2) The compressor's maximum speed during a powerful operation will be reset 60 minutes later,
and the lower limit speed is increased for 180 minutes after being set to powerful operation or for
180 minutes after the thermometer is reset.
(3) The thermometer is forcibly turned on for 20 minutes after the powerful operation is reset.
(4) Pressing the as-desired button during powerful operation will cancel the powerful operation.
(5) If the sleep timer is set during powerful operation, the powerful operation will be canceled.
(6) If the fan speed of the remote control is set to AUTO or "HI", the compressor's
maximum speed during powerful operation will be set to CMAX2 and the lower limit speed
CKYMIN_PW.
(7) If the fan speed of the remote control is set to "MED", the compressor's maximum speed
during powerful operation will be CJKMAX_PW and the lower limit speed CJKMIN_PW.
(8) If the fan speed of the remote control is set to "LOW", the compressor's maximum speed
during powerful operation will be set to CBEMAX_PW. The lower limit speed is CBEMIN_PW.
(9) If the fan speed of the remote control is set to "SILENT", the compressor's maximum speed during
powerful operation will be CSZMAX_PW. The lower limit speed is CSZMIN_PW.
Room low-temperature defrost
Room heat exchanger temperature
Low-temperature
defrost signal
Latch-type
reversing valve
Balancing period
Indoor unit
HI
MED
LOW
SILENT
Outdoor unit
See "Basic mode".
See "Basic mode".
CMINHI
– 68 –
The temperature setting is not shifted with time elapsed.
Содержание RAC-10SH3
Страница 57: ... 55 MODEL RAC 18SH3 Unit mm 580 5 600 345 299 19 5 ...
Страница 60: ... 8 5 WIRING DIAGRAM MODEL RAS 10SH3 3 H S 4 1 S A R 3 H S 8 1 S A R INDOOR UNIT ...
Страница 62: ... 0 6 MODEL RAC 18SH3 OUTDOOR UNIT WHT YEL RED INDOOR UNIT ...
Страница 64: ... 2 6 3 H S 8 1 S A R 3 H S 4 1 S A R 3 H S 0 1 S A R L E D O M ...
Страница 150: ... 8 4 1 MODEL RAC 18SH3 ...
Страница 153: ...HHAW NO 0060E RAS 10SH3 RAC 10SH3 RAS 14SH3 RAC 10SH3 RAS 18SH3 RAC 18SH3 ...