background image

MODEL

RA-08MF / RA-08MEF
RA-10MF / RA-10MEF
RA-13MF / RA-13MEF

SAFETY PRECAUTION

 

Read the safety precautions carefully before operating the unit.

  The contents of this section are vital to ensure safety. Please pay special attention to the following sign.

  

WARNING ........ Incorrect methods of installation may cause death or serious injury.

  

CAUTION ......... Improper installation may result in serious consequence.

  

The sign in the 

fi

 gure indicates prohibition.

 

Be sure that the unit operates in proper condition after installation. Explain to customer the proper way of operating the unit 
as described in the user’s manual.

!
!

PRECAUTIONS DURING SHIFTING OR MAINTENANCE

●  

If abnormal situation arises (like burning smell), please stop the unit and turn off the circuit breaker. 
Fault, short circuit or 

fi

 re may occur if the unit is continue to operate under abnormal situation.

  Please contact your agent for maintenance. Improper maintenance may cause electric shock and 

fi

 re.

●  

Please contact your agent if need to remove and reinstall the unit. Electric shock or 

fi

 re 

may occur if you remove and reinstall the unit improperly.

WARNING

PRECAUTIONS DURING INSTALLATION

  Please ask sales agent or quali

fi

 ed technician for the installation of the unit. Water leakage, short 

circuit or 

fi

 re may occur if install the unit improperly.

  Please use earth line.

  Do not place the earth line near water or gas pipes, lightning-conductor, or the earth line of telephone. 

Improper installation of earth line may cause electric shock.

  A circuit breaker should be installed depending on the mounting site of the unit. Without a circuit 

breaker, the danger of electric shock exists.

  Do not install near location where there is 

fl

 ammable gas. The unit may catch 

fi

 re  if 

fl

 ammable  gas 

leaks around it.

  If drain pan is used, please ensure that when installing the drain hose, water is able to 

fl

 ow  freely 

without any obstruction.

CAUTION

!

!

!

PARTS IDENTIFICATION AND OPERATIONS

  1

   Cabinet

  2

   Suction Grille

 

3

 Front 

Cover

  4

   Horizontal De

fl

 ectors

  5

   Vertical De

fl

 ector

 

6

   Air Exhaust Lever

  7

   Switch Panel Cover

  8

   Auto Swing Switch

  9

   Operation Mode Selection Dial

 10

  Thermostat Dial

Model

RA-08MF/RA-08MEF
RA-10MF/RA-10MEF

RA-13MF/RA-13MEF

Width

18 

1

2

”, 470mm

22 

3

64

”, 560mm

Height

13 

1

2

”, 345mm

14 

3

4

”, 375mm

Depth

25 

3

16

”, 640mm

27 

29

32

”, 709mm

AUTO SWING

OPERATION MODE SELECTOR DIAL

  When the AUTO SWING switch is turned to “ON” position, the vertical de

fl

 ectors automatically oscillate right and left 

sweeping the cold air alternately to obtain comfortable cooling.

  The vertical de

fl

 ectors will stop to swing when the AUTO SWING switch is turned “OFF”

OFF

LO FAN

HI FAN

LO  COOL

HI COOL

Stop the fan and cooling operation.

Fan operation only at low speed.

Fan operation only at high speed.

Cooling operation with low fan speed. This is recommended for sleeping comfort.

Cooling operation with high fan speed for maximum cooling power.

  The start of operation will occur an abnormal sound (turbo sound) which doesn’t affect the operation.

THERMOSTAT DIAL

Setting the desired room temperature. Turn the dial further clockwise for cooler indoor temperature.

  Do not set the dial to “TEST” for normal usage. This setting is only for technician. If the unit 

is operate at “TEST” for normal use, it may cause the evaporator frosted and consequence 
of no cooling, noisy and water leakage may be found. 

  If the evaporator is found frosted, it means the temperature at evaporator is too low. Please 

turn the dial anti-clockwise and check if any obstacle in front of air outlet and inlet like curtain.

  When the compressor stops, please wait 3 minutes before turning the dial clockwise.

!

CAUTIONS

AIR DEFLECTORS

Vertical de

fl

 ectors at both sides of outlets can be set to 

either auto-swing or static position to direct discharge air 
rightward, leftward or forward direction.

Horizontal de

fl

 ectors at both sides of the outlets can 

be set to direct discharge air upward, downward or 
forward direction.

VERTICAL DEFLECTORS

HORIZONTAL DEFLECTORS

To avoid dew forming on the de

fl

 ectors which eventually may drip to the 

fl

 oor, please do not adjust horizontal de

fl

 ectors 

extremely downward position or vertical de

fl

 ectors extremely leftward or rightward position during cool operation for a long 

time.
Also, do not adjust the vertical de

fl

 ectors position by hand or any other object.

!

CAUTIONS

AIR EXHAUST LEVER

WASABI AIR PURIFYING FILTER

Set the air exhaust lever to the down ( OPEN) position for air 

       

ventilation in the room. The air exhaust lever should normally be kept 
in up ( CLOSE) position during cooling operation and in the case of 
typhoon.

Always stop the operation before installing the wasabi air purifying 

fi

 lter.

Wasabi air purifying 

fi

 lter are not washable. It is recommended to use vacuum to clean it. It can be used use for 1 year 

time. Type number for this  wasabi air purifying 

fi

 lter is <SPX-CFH9W>. Please use this number for ordering when you 

want to renew it.

1. Pull and remove the suction grille

2. Remove the pre-

fi

 lter

3. Install the wasabi air purifying 

fi

 lter in the frame

4.  Install back the pre-

fi

 lter  and 

close the suction grille

NOTES ON OPERATION

TEMPERATURE AND HUMIDITY

Avoid to use the room air conditioner for cooling operation when the outside temperature is below 21°C (70°F). Recommended 
operation humidity should be below 80%. Continuous operation at over 80% humidity (indoor) will cause some dews form 
on the outlet grille and de

fl

 ectors of the unit.

NOISE

In a quiet environment during the starting or stopping the operation, phenomena like 

fl

 owing sound of refrigerant in the 

refrigerating cycle and rubbing noise from the fan casing may occasionally occur, but this is normal for the operation.
Water will be condensed on the evaporator coil and collected in the bottom tray, it is picked up by the condenser fan and 
blown onto the condenser coil, this creates a “splashing” sound which is normal.

ODOR

The odor will possibly be emitted from the room air conditioner especially at the starting of operation and in a high 
humidity condition. This is not abnormal phenomena because of the various kind of odors emitted by smoke, food stuffs, 
cosmetics and others which may stick to the room air conditioner. So, the pre-

fi

 lter and the evaporator regularly must be 

cleaned to reduce the odor.

THE IDEAL WAYS OF OPERATION

Suitable Ro

om

 Temperature

     

   

Warning

Freezing temperature 
is bad for health and a 
waste of electric power.

!

Install curtain or blinds

It is possible 
to reduce heat 
entering the room 
through windows.

Ventilation

       

Caution

Do not close the room for a long period of 
time. Occasionally 
open the door and 
windows to allow the 
entrance of fresh air.

!

Do Not Forget To Clean The Pre-Filter

Dusty pre-

fi

 lter will reduce the air 

volume and the cooling ef

fi

 ciency. 

To prevent from wasting electric 
energy, please clean the pre-

fi

 lter 

every 20 days.

Please Adjust Suitable Temperature 

For Baby And Children

Please pay attention to the 
room temperature and air 

fl

 ow 

direction when operating the 
unit for baby, children and old 
people who have dif

fi

 culty in 

movement.

FOR USER’S INFORMATION

The Air Conditioner And The Heat Source In The Room

    Caution

If the amount of heat in the room is above the cooling capability of the air conditioner (for 
example: more people entering the room, using heating equipments and etc.), the preset 
room temperature cannot be achieved.

!

When Lightning Occurs

    Warning

To protect the unit during lightning, please stop operating the unit and remove the plug 
from the socket.

!

<

IA0000: A 

>

WINDOW  TYPE  ROOM  AIR  CONDITIONER 
OPERATION  AND  INSTALLATION  MANUAL

WARNING

INS RA-08-10-13MF/MEF.indd   1

9/28/15   4:37 PM

Отзывы: