D8UF
18
1. ADJUSTMENT PROCEDURE START-
UP
The PDP TV sets run through a series of adjustments during
the assembly process.
Also, after servicing, these same adjustments must be done.
The adjustments are all made through the Service Mode
Menu.
NOTE: - S/W Check and upgrade -
The software version of the TV set can be checked through
the user OSD by following the next menu path:
[MENU] -> Setup -> Reset the Software>
The next picture shows the OSD where the version is
shown.
Till this day the latest software versions are:
Model
Main S/W
Sub S/W
P50S602
V0103.0001
V04.17
P50A402
V0105.0001
V04.17
P50A202
V0105.0001
V04.17
Software versions are subject to change for improvement.
Contact
1-800
Hitachi, or www.hitachiserviceusa.com
The software upgrade is done by inserting an SD/MMC card
with the software
fi
les thru the side panel slot. After inserting
the card press the “Upgrade Now” OSD button in the above
shown OSD screen and wait for the upgrade process to
fi
nish. After, press the side panel power button off, remove
the SD/MMC card, and press the power button on.
NOTE
: Any power interruption during the upgrade process
will cancel the upgrade. When this happens, repeat the
upgrade process.
1.1 How to get to the Service Mode Menu
The Service Mode Menu can be reached by following the
next sequence:
1.
Turn the PDP TV set to power-On and with the remote
control push MENU -> MENU -> 8 -> SELECT.
2.
To exit the Service Mode press [EXIT] key of the remote
control or the PDP side control panel.
The next picture shows the Service Mode OSD for the PDP
TV set.
In the
fi
rst line of the Adjustment mode OSD, the model num-
ber and the board information number are shown.
Model
Board Information
P50S602
DF1E
P50A402
DF1E
P50A202
DF3E
1.2 Changing data and selecting adjustment
codes.
When the PDP TV is in the Service Mode, use the remote
control cursor keys
◄
,
►
,
▲
,
▼
to make the adjustments.
The side control panel in the PDP TV set can also be used
for making the adjustments.
A. Use the Remote Control:
The
▲
,
▼
, keys are used for scrolling thru the adjustment
item (in the same page).
The Select key is used for entering to the adjustment item
sub-menu.
The
◄
,
►
keys are used for changing the data values.
Use the MENU remote control button to scroll thru the
diferent service mode pages.
The “OK” button is equal to “Enter” key.
The next picture shows part of the R/C indicating the buttons
mentioned in the previous explanation.
ADJUST MODE(PDP-50S602)DF1E
> FACT RESET
MEMORY INIT
RGB
WHITE BAL HIGH
WHITE BAL MED
WHITE BAL STD
WHITE BAL D.CINE
MENU
button
cursor
buttons
SELECT
button
No. 8 button
EXIT
button
Main S/W
Sub S/W
For the latest version of software.
Содержание P50A202/D8UF
Страница 63: ...D8UF TABLE OF CONTENTS Schematic Diagram page 20 63 1 MAIN BOARD SHEET 001 Slow Bus Flash ...
Страница 67: ...D8UF TABLE OF CONTENTS Schematic Diagram page 20 67 MAIN BOARD SHEET 006 Seine2A Video in 5 ...
Страница 71: ...D8UF TABLE OF CONTENTS Schematic Diagram page 20 71 MAIN BOARD SHEET 010 VCXO PLL 9 sheet 11 ...
Страница 77: ...D8UF TABLE OF CONTENTS Schematic Diagram page 20 77 16 16 MAIN BOARD SHEET 017 Terminal 15 ...
Страница 78: ...D8UF TABLE OF CONTENTS Schematic Diagram page 20 78 MAIN BOARD SHEET 018 Fan 16 from sheet 13 Sub cpu ...
Страница 79: ...D8UF TABLE OF CONTENTS Schematic Diagram page 20 79 MAIN BOARD SHEET 018 Fan 17 from sheet 13 Sub cpu ...
Страница 81: ...D8UF TABLE OF CONTENTS Schematic Diagram page 20 81 SUB BOARD SHEET 01 LED 19 to sheet 13 Sub cpu ...
Страница 82: ...D8UF TABLE OF CONTENTS Schematic Diagram page 20 82 SUB BOARD SHEET 02 CONTROL 20 to sheet 13 Sub CPU ...
Страница 92: ...PA NO 0235 MADE IN MEXICO ...