background image

 

 

 

 
 
 

KP-F80   

Progressive Scan 

B/W CCD Camera   
Operation Guide

 

 
 
 
 
 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание KP-F80

Страница 1: ...KP F80 Progressive Scan B W CCD Camera Operation Guide ...

Страница 2: ...al 1 2 Composition 1 3 Specifications 1 4 Adjustment 3 5 Timing chart 5 6 External view 9 7 External sync 10 8 Connect cables 11 9 Optical system 12 10 Optional 13 11 Notes to users 16 Attachment Spectral sensitivity characteristic 18 ...

Страница 3: ...more contribute to versatility that meets a wide range of needs The square pixel CCD also renders an image appropriate for image processing systems 2 Composition 1 Black and white camera With IR cut filter 1 2 Operation manual 1 3 Specifications 1 Imaging device 1 3 inch progressive scan interline CCD Total pixels 1077 H 788 V Effective pixels 1034 H 779 V Pixel size 4 65 H 4 65 v µm 2 Sensing are...

Страница 4: ...ger fixed shutter and Reset control Partial scan option Factory setting is off 15 Power supply voltage 12 1 VDC 16 Power consumption Approx 2 2 W 17 Ambient temperature and humidity Operating 10 to 50 RH less than 90 Storage 20 to 60 RH less than 70 Caution For continued stable operation the camera should be used under 40 or less when it is used continuously for extended period of time 18 Anti vib...

Страница 5: ...ATION HIGH 75ohm INPUT IMPEDANCE EXTERNAL HD AND EXTERNAL VD FRAME ON DEMAND E SHUTTER SHUT SCAN MODE H TERM V TERM ONE TRIGGER MODE FIXED SHUTTER TRIGGER RESET CONTROL PARTIAL SCAN TRIGGER OPTION GAIN control MIN MAX 1 2 3 4 5 6 7 8 9 0 Normal 1 250s 1 500s 1 1000s 1 2000s 1 4000s 1 10000s 1 50000s ...

Страница 6: ...GND GND 12V GND Vout Vout GND HD HD IN OUT VD IN OUT GND NC WEN GND VD GND 12V GND Vout Vout GND HD HD IN OUT Trigger GND NC WEN GND Trig GND 12V GND Vout Vout GND HD HD IN OUT Trigger GND NC WEN GND Trig GND 12V GND Vout Vout GND HD HD IN OUT Trigger VD GND NC WEN Trigger B GND Trig GND 12V GND Vout Vout GND HD HD IN OUT Trigger GND NC WEN GND Trig Reset control Partial OPTION Frame on demand JU ...

Страница 7: ... H BLK 246 8 20us 18 0 60us 60 2 00us 168 5 60us 1024 42 3us 1270 1077 clk 33 33nsec KP F80 CCD OUTPUT WAVE TIMING CHART H Drive CCD pixel and Hregister array CCD output signal Composit video signal H register transfar stop Optically black Dummy H register Photosensing period Output video period ...

Страница 8: ...5 Timing chart KP F80 6 11H 9H 4H 779 778 777 3 2 1 6 5 4 1 7 7 4 2 24 1H 42 33uS 11 10 9 8 7 6 5 4 3 2 2H KP F80 Timming chart Vertical Video out V Drive BLK H Drive CCD out WEN out ...

Страница 9: ...YNC Video output 5Vp p Low 0V High 5V Reset control Integration time 1 Trigger pulse 3H 250ms 1 1 Please inquire Integration time 1 2us approx 2us approx 2us approx KP F80 Frame on demand function Trigger B pulse Asynchronous Trigger pulse Latch in internal HD Trigger pulse Latch in internal HD Trigger pulse Asynchronous NOTE The latch and non latch can be changed 2us approx 2us or more 2us approx...

Страница 10: ...rigger The camera shifts to the output of a normal mode continuous output when Trigger B signal passes about 1 3 seconds in the state of High The image is output by inputting the Trigger at the VD cycle for this period It returns to the Trigger mode if Trigger B signal becomes Low However after becoming Low Trigger B the period of 50ms becomes a Trigger signal input prohibition period ...

Страница 11: ...6 External view Dimensions KP F80 9 ...

Страница 12: ...ve VD 4 to 6 VDC negative Trigger 4 to 6 VDC Input impedance 75ohm or High impedance 10kohm Trigger B Pin 11 1kohm HD VD T 1 f H Vertical drive signal VD Horizontal drive signal HD Set HD and VD fallings edges to the same phase 0 2 µs HD and VD phase relationship Drive signal input waveform Approx 3 1µs 4 6VDC Approx 0 4ms 4 6VDC T 1 f V ...

Страница 13: ...8 Connect cables KP F80 11 Connection of options ...

Страница 14: ...ith an IR cut filter IR cut filter removal 3 2 4 1 a Remove two screws 1 shown in Fig and filter holder 2 will come off b Remove the IR cut filter 3 from filter frame 4 c Reinstall and secure filter holder 2 with two screws 1 Caution Prior to removing the optical filter be sure to turn off the power IR cut filter IRC650 Dimensions 14 x 12 x 1 0t Part code XMD0006 The flange focal point shortens by...

Страница 15: ...10 Optional 1 Tripod adaptor TA F30 23885AX 2 12 pin plug HR10A 10P 12S 01 Product code 23810AX 1 2 3 4 5 6 7 8 9 10 12 11 Viewed from this side KP F80 13 ...

Страница 16: ...Shielded type 2m C 201KSM 23861AX C 201KS 23856AX C 201KSS 23872AX 5m C 501KSM 23862AX C 501KS 23857AX C 501KSS 23873AX 10m C 102KSM 23863AX C 102KS 23858AX C 102KSS 23874AX Specify assembly or shielded type at time of order Product code We will recommend the camera cable of the shield type when using it in the sphere of CE KP F80 14 ...

Страница 17: ...portionate to the cable length Characteristic impedance is kept at constant even at cable length change 1 2 3 4 5 6 7 8 9 10 12 11 RED WHT YEL ORN WHT BLK BRN GRY BLU YEL YEL WHT Cable length Attenuation at 4MHz 50dB Km Attenuation at 7MHz 70dB Km Attenuation at 12MHz 90dB Km 1m 0 05 0 07 0 09 2m 0 1 0 14 0 18 5m 0 25 0 35 0 45 Attenuation due to cable length dB 10m 0 5 0 7 0 9 The video bandwidth...

Страница 18: ...ding rise of internal temperature When casing the camera the temperature normally rises by 10 to 20 compared with the outside air temperature The camera operates in the temperature range from 5 to 45 If the camera is used or left in high temperature environment for hours the life of the camera may be shortened Do not drop the camera Do not apply strong shock or vibration to the camera Before conne...

Страница 19: ...angle of the camera so that such strong light does not enter the camera through the lens Fixed pattern noise When the camera is operated in a high temperature fixed pattern noise may appear on the entire screen The higher the sensitivity of camera the more this fixed pattern noise appears Moire When fine patterns are shot moire may be displayed The CE mark is required when exporting to Europe Obta...

Страница 20: ...Spectral sensitivity typical example KP F80 18 ...

Страница 21: ...fects due to erroneous use or intentional act are excluded 2 As the defect after expiration of the guarantee period Hitachi Denshi will repair the equipment if the intended function is restored by the repair work and the cost is changed to a customer 3 Hitachi Denshi is not liable for the losses caused when the equipment is used in a system used for business trades production process medical field...