3 After the completion of the automatic adjustment, when the Back key
is pressed, the auto phase detection voltage is output and therefore,
confirm the waveform by an oscilloscope.
Using the oscilloscope, confirm that the voltage of TP1 (APH signal) on the EZJ106
board is from 8 to 10 V as the maximum voltage, 2 V or less as the minimum voltage,
and is “normal” as shown in the following figure.
4 When the automatic adjustment is not normally completed or the
waveform is “abnormality”, confirm that the periphery of the gutter part is
made dirty with ink or makeup ink. When dirtiness or the like is present,
wash the periphery of the gutter part, surely dry it and then, perform the
automatic-adjustment again.
Numerical values of the auto phase gain value can also be input by a ten-key. To the
value set at present, if the auto phase gain value is set large, the gain becomes high,
whereas if it is set small, the gain becomes low. When the “Back” key is input, the
auto phase detection voltage is output and the auto phase gain value is reflected.
With respect to positions of
the board and the test pin,
refer to " 3.3.2 EZJ106 board".
Normal
Maximum voltage
from 8 to 10 V
,
minimum voltage 2 V
or less
10ms
Noise small
Abnormality
Noise large
2-13
Содержание IJ PH
Страница 1: ...Service Manual HITACHI Printer Model PH Revision Aug 2011 Version First edition ...
Страница 2: ... Revision of PH service manual Revision Chapter Revised Page ...
Страница 13: ...1 2 2 Main body internal PH D 1 8 ...
Страница 80: ...3 25 3 25 Circuit diagram of EZJ95 ...
Страница 201: ...7 1 7 Attached Drawing 7 1 Circulation System Diagram ...
Страница 202: ...7 2 7 2 Electrical Connection Diagram ...
Страница 205: ...7 5 7 4 Dimensions around charge electrode and deflection electrode Nozzle diameter 65 um ...