6-60
6.6.8 Power Restoration Procedure
Power Restoration Procedure
YES
NO
Is the EZJ93 board
CN3 connector
disconnected or in
poor contact?
Normality is restored when the
connector is disconnected and then
reconnected.
Replace the EZJ124 board
Resume the
operation.
Is the EZJ124 board
CN3 connector
disconnected or in
poor contact?
Does the fault recur?
Replace the EZJ93 board.
YES
NO
YES
NO
System reset with Rescue CF
card.
Does the fault recur?
YES
NO
Does the fault recur?
YES
NO