1.3 Installation
1.3.1
Wiring of power supply
[The usable power cable]
The power cable must conform to following conditions.
Connector specification : IEC inlet connector (3 pin L type)
Use the connector of following form and sizes
indicated below.
Cable outer diameter
:
7-10mm
Conductor size :
0.75mm
2
or more
Cable length : Less than 5m (Please shorten as much as possible.)
Other specifications
: Use the cable according to the safety standard in
each country.
[Notes about UL]
When the IJ printer is used in North America, the power cable must conform to
following conditions besides the above-mentioned conditions.
Standard : UL and CUL recognition parts
Rating : 125V,More than 7A
Plug : NEMA5-15P
Cable : Type SJT,18AWG,More than 60 degrees C.
Cable length : 1.5 to 4.5 m
1-10
min18
7 to 10
38.5 - 44.5
Max
25
M
a
x
60
M
a
x
30
Pay attention to the direction
of the cable.
Unit: mm
・
Be sure to use an appropriate plug and connect a protective ground.
・
Place a wall socket in the vicinity of the unit so as to easily remove it.
・
Use a power cable within the designated specifications.
・
Do not bundle a signal level cable and a power cable together outside
the unit so that the signals (signal terminal block, a connection signal to
an external communication connector) are not affected by a noise from
a power cable.
Caution
!
Содержание IJ PH
Страница 1: ...Service Manual HITACHI Printer Model PH Revision Aug 2011 Version First edition ...
Страница 2: ... Revision of PH service manual Revision Chapter Revised Page ...
Страница 13: ...1 2 2 Main body internal PH D 1 8 ...
Страница 80: ...3 25 3 25 Circuit diagram of EZJ95 ...
Страница 201: ...7 1 7 Attached Drawing 7 1 Circulation System Diagram ...
Страница 202: ...7 2 7 2 Electrical Connection Diagram ...
Страница 205: ...7 5 7 4 Dimensions around charge electrode and deflection electrode Nozzle diameter 65 um ...