6-12
6.2.9 Deflection Voltage Fault
Deflection Voltage
Fault
Is the EZJ106 board CN6
connector or high-voltage
power supply CN1
connector disconnected?
Connect the connector.
Disconnect the connector and then
reconnect it.
Does the printer
become ready for
printing?
Yes
No
END
Yes
No
Replace the high-voltage
power supply unit.
Does the printer
become ready for
printing?
Yes
No
Replace the EZJ106 board.
END
Does the printer
become ready for
printing?
Yes
No
Replace the EZJ93 board.
END
Содержание IJ PH
Страница 1: ...Service Manual HITACHI Printer Model PH Revision Aug 2011 Version First edition ...
Страница 2: ... Revision of PH service manual Revision Chapter Revised Page ...
Страница 13: ...1 2 2 Main body internal PH D 1 8 ...
Страница 80: ...3 25 3 25 Circuit diagram of EZJ95 ...
Страница 201: ...7 1 7 Attached Drawing 7 1 Circulation System Diagram ...
Страница 202: ...7 2 7 2 Electrical Connection Diagram ...
Страница 205: ...7 5 7 4 Dimensions around charge electrode and deflection electrode Nozzle diameter 65 um ...