419
Item
Symbol
Min
Typ
Max
Unit
Test
Conditions
Input
leakage
RES
|I
in
|
—
—
10.0
µ
A
V
in
= 0.5 to
V
CC
– 0.5 V
current
STBY
, NMI,
MD2 to MD0
—
—
1.0
µ
A
Port 4,
P54 to P57
—
—
1.0
µ
A
V
in
= 0.5 to
AV
CC
– 0.5 V
Three-state
leakage
current
(off state)
Ports 1 to 3,
P50 to P53,
ports 6 to 8,
ports A to H
|I
TSI
|
—
—
1.0
µ
A
V
in
= 0.5 to
V
CC
– 0.5 V
Input pull-up
MOS current
Ports A to E
–I
p
10
—
300
µ
A
V
CC
= 2.7 to
3.6 V
V
in
= 0 V
Input
RES
C
in
—
—
30
pF
V
in
= 0 V
capacitance NMI
—
—
30
pF
f = 1 MHz
All input pins
except
RES
and NMI
—
—
15
pF
T
a
= 25°C
Current
dissipation
*
4
Normal operation I
CC
*
6
—
80
(3.3 V)
150
mA
f = 33 MHz
Sleep mode
—
70
(3.3 v)
125
mA
f = 33 MHz
Standby mode
*
5
—
0.01
10
µ
A
T
a
≤
50°C
—
—
80
µ
A
50°C < T
a
Analog
power
During A/D and
D/A conversion
AI
CC
—
0.3
(3.0 V)
2.0
mA
supply
current
Idle
—
0.01
5.0
µ
A
Reference
power
During A/D and
D/A conversion
AI
CC
—
1.4
(3.0 V)
4.0
mA
supply
current
Idle
—
0.01
5.0
µ
A
RAM standby voltage
V
RAM
2.0
—
—
V
Notes: 1. If the A/D and D/A converters are not used, do not leave the AV
CC
, V
ref
, and AV
SS
pins
open. Connect the AV
CC
and V
ref
pins to V
CC
, and the AV
SS
pin to V
SS
.
2. When used as
IRQ0
to
IRQ15
.
3. When used as other than
IRQ0
to
IRQ15
.
4. Current dissipation values are for V
IH
min = V
CC
– 0.5 V and V
IL
max = 0.5 V with all
output pins unloaded and all MOS input pull-ups in the off state.
5. The values are for V
RAM
≤
V
CC
< 2.7 V, V
IH
min = V
CC
×
0.9, and V
IL
max = 0.3 V.
Содержание H8S/2670
Страница 5: ......
Страница 9: ......
Страница 199: ...182 ...
Страница 361: ...344 ...
Страница 393: ...376 ...
Страница 647: ...630 ...