8
.
Confirm that the pair status of the P-VOLs of the GAD pairs is
PSUS(Block) and that the pair status of the S-VOLs is SSWS(Local).
pairdisplay -g oraHA -fcxe -IH1
9
.
Wait for more than 5 minutes after completing step 4, and then
resynchronize the GAD pairs from the secondary storage system by
reversing the primary and secondary volumes (swap resync).
pairresync -g oraHA -swaps -IH1
10
.
Confirm that the pair status of the P-VOls and S-VOLs of the GAD pairs
has changed to PAIR (Mirror (RL)).
pairdisplay -g oraHA -fcxe -IH1
11
.
Using the alternate path software, resume I/O from the servers to the
storage system at the primary site.
12
.
If necessary, reverse the primary and secondary volumes.
Planned power off/on of the primary and secondary storage
systems
Powering off the primary and secondary storage systems
1
.
Stop server I/O to the primary and secondary storage systems.
2
.
On the primary storage system, suspend the GAD pairs by specifying the
primary volume.
pairsplit -g oraHA -r -IH0
3
.
Confirm that the pair status of the P-VOLs of the GAD pairs has changed
to PSUS(Local) and that the pair status of the S-VOLs has changed to
SSUS(Block).
pairdisplay -g oraHA -fcxe -IH0
4
.
Power off the primary and secondary storage systems.
Powering on the primary and secondary storage systems
1
.
Power on the primary and secondary storage systems.
2
.
Confirm that the primary and secondary storage systems and the external
storage system for the quorum disks do not have any blocked parts.
If any parts are blocked, recover them.
3
.
Check for SIMs about path blockage, and delete the SIMs.
4
.
Confirm that the pair status of the P-VOLs of the GAD pairs is PSUS(Local)
and that the pair status of the S-VOLs is SSUS(Block).
pairdisplay -g oraHA -fcxe -IH0
5
.
On the primary storage system, resynchronize the GAD pairs by
specifying the primary volume.
pairresync -g oraHA -IH0
6
.
Confirm that the pair status of the P-VOLs and S-VOLs of the GAD pairs
has changed to PAIR (Mirror (RL)).
7-6
Planned outage of global-active device storage systems
Hitachi Virtual Storage Platform G1000 Global-Active Device User Guide
Содержание G1000
Страница 8: ...Index viii Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 14: ...xiv Preface Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 60: ...2 22 System requirements Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 80: ...3 20 Planning for global active device Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 128: ...4 48 Configuration and pair management using CCI Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 238: ...9 18 Troubleshooting Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 245: ...Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...