Pair status
I/O mode
Procedure
P-VOL
S-VOL
P-VOL
S-VOL
PSUS/
PSUE
SSWS
Block
Local
Resynchronize the pair specifying the S-
VOL.
SMPL
SSWS
Not
applicabl
e
Local
1
.
Delete the pair specifying the S-VOL.
2
.
When the virtual LDEV ID is set to
the P-VOL, delete the virtual LDEV
ID, and then set the reservation
attribute to the P-VOL.
3
.
Recreate the pair specifying the S-
VOL.
PSUS/
PSUE
SSUS/
PSUE
Local
Block
Resynchronize the pair specifying the P-
VOL.
SMPL
SSUS/
PSUE
Not
applicabl
e
Block
1
.
Delete the pair forcibly from the
secondary system, specifying
Disable
in the
Volume Access
field
(
Delete Pairs
window).
2
.
Release the reservation attribute of
the P-VOL, and then set the same
virtual LDEV ID that was used before
the pair was deleted.
3
.
Recreate the pair specifying the P-
VOL.
7
.
If the alternate path to the P-VOL has been deleted, add the alternate
path.
a
.
If you have detached the channel port connection paths of the
primary site, restore all channel port connection paths to their original
status, and then add the alternate path.
b
.
Using the alternate path software, add the alternate path deleted at
step 1 to the P-VOL.
Related topics
•
Pair condition before failure on page 6-7
Pair condition and recovery: secondary system failure
The following table shows transitions for pair status and I/O mode, the
volumes accessible from the server, and location of the latest data when you
can no longer use the secondary system due to failure.
Disaster recovery of global-active device
6-31
Hitachi Virtual Storage Platform G1000 Global-Active Device User Guide
Содержание G1000
Страница 8: ...Index viii Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 14: ...xiv Preface Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 60: ...2 22 System requirements Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 80: ...3 20 Planning for global active device Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 128: ...4 48 Configuration and pair management using CCI Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 238: ...9 18 Troubleshooting Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 245: ...Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...