76 | 108
E-Compact MP-BB3 Series
4.6.5. Power Amplifier Signaling LED’s
Each Power Amplifier Drawer Features an LED bank that indicates its operation status according to the
colors as shown below:
Green
Normal operation
Orange
Orange light indicates that a failure has
occurred
Red
Flashing Red light indicates an
ongoing
failure
LED
ALARM
PWR
N/A - This LED lights only GREEN indicating that is POWERED ON
SHDN
Power Supply Shutdown
FWD
Over Forward Power (Overdrive)
RFD
Reflected Power
PA
PA Failure, High Current on PA, Low Current on PA, Current UNBAL on PA, Low
Gain on PA, High Temperature on PA, Communication Failure on PA
DRV
High Current on Driver, Low Current on Driver, Low Current on Pre Driver, High
Current on Pre Driver, Low Gain on Driver, High Temperature on Driver, Low
Voltage on Driver, Communication Failure on Driver, High Input Signal, High
Driver Output Level
PSU
Low AC Line Voltage, High AC Line Voltage, Low PSU Voltage, High PSU Voltage,
High PSU Current, High PFC Temperature, High DC/DC Temperature, PSU
Communication Failure
FAN/TEMP
When detecting a slow speed of rotation or complete failure in any of the fans.
High temperature input air of the power drawer (greater than 35ºC).
Alarm details are displayed by accessing the keyboard-display interface of the Control Module CM9001
in the menus:
> Main Menu > System Alarms/Log > Drawers Alarms
PWR
SHDN
FWD
RFD
PA
DRV
PSU
FAN/
TEMP
Содержание EC702MP-BB3
Страница 34: ...34 108 E Compact MP BB3 Series H G F E D C B A 8 7 6 5 4 3 2 1 H G F E D C B A 8 7 6 5 4 3 2 1 ...
Страница 68: ...68 108 E Compact MP BB3 Series VGS Carrier Software Version 1 75 1 70 1 71 1 78 ...
Страница 84: ...84 108 E Compact MP BB3 Series B220 BIPHASIC 220VAC 2 PHASE 110VAC GND ...
Страница 85: ...85 108 E Compact MP BB3 Series M220 SINGLEPHASE 220VAC 1 PHASE NEUTRAL GND ...
Страница 106: ...106 108 E Compact MP BB3 Series Section 8 Attachments ...
Страница 108: ...108 108 E Compact MP BB3 Series ...