A
BOUT
THE
S
YSTEM
E
NABLING
THE
I
NTEL
® VMD T
ECHNOLOGY
1-15
Storage Drive LED
Front 3.5” Storage Drive LED Status Behavior
Figure 1-9.
3.5” Storage Drive LED Identification
The following LED behavior table represents LED conditions.
Enabling the Intel® VMD Technology
Note:
You can use Intel® VROC HII to create the RAID volume. These volumes can be created at any point before or
after your system is successfully running your Windows installation, but may not be used as the boot
volume.
To enable the Intel VMD technology feature, you might need to select “Intel® VMD
technology” in “IIO configuration” under the “Socket Configuration” screen from BIOS
Main screen.
10M active link
Off
Blinking green
Table 12: 3.5” Storage Drive LED Status Behavior
N
AME
C
OLOR
C
ONDITION
D
ESCRIPTION
Drive Status / Fault
Blue
On
Drive is online
Blinking
Twice per second: Identification
Once per second: Rebuilding
Amber
On
HDD failure
Off
Slot is empty
Drive Active
Blue
Blinking
HDD access is active
Table 11: RJ45 LED Description (Continued)
C
ONDITION
L
INK
A
CTIVITY
Status / Fault LED
Active LED