RS-232C Communication / Network command table (continued)
22
(continued on next page)
Names
Operation Type
Header
Command Data
CRC
Action
Type
Type
HDMI FORMAT
Set
AUTO
BE EF
03
06 00
BA 77
01 00
13 22
00 00
VIDEO
BE EF
03
06 00
2A 76
01 00
13 22
01 00
COMPUTER
BE EF
03
06 00
DA 76
01 00
13 22
02 00
Get
BE EF
03
06 00
89 77
02 00
13 22
00 00
HDMI RANGE
Set
AUTO
BE EF
03
06 00
86 D8
01 00
22 20
00 00
NORMAL
BE EF
03
06 00
16 D9
01 00
22 20
01 00
ENHANCED
BE EF
03
06 00
E6 D9
01 00
22 20
02 00
Get
BE EF
03
06 00
B5 D8
02 00
22 20
00 00
COMPUTER IN1
Set
AUTO
BE EF
03
06 00
CE D6
01 00
10 20
03 00
SYNC ON G OFF
BE EF
03
06 00
5E D7
01 00
10 20
02 00
Get
BE EF
03
06 00
0D D6
02 00
10 20
00 00
COMPUTER IN2
Set
AUTO
BE EF
03
06 00
32 D7
01 00
11 20
03 00
SYNC ON G OFF
BE EF
03
06 00
A2 D6
01 00
11 20
02 00
Get
BE EF
03
06 00
F1 D7
02 00
11 20
00 00
FRAME LOCK –
COMPUTER IN1
Set
OFF
BE EF
03
06 00
3B C2
01 00
50 30
00 00
ON
BE EF
03
06 00
AB C3
01 00
50 30
01 00
Get
BE EF
03
06 00
08 C2
02 00
50 30
00 00
FRAME LOCK –
COMPUTER IN2
Set
OFF
BE EF
03
06 00
0B C3
01 00
54 30
00 00
ON
BE EF
03
06 00
9B C2
01 00
54 30
01 00
Get
BE EF
03
06 00
38 C3
02 00
54 30
00 00
FRAME LOCK -
HDMI
Set
OFF
BE EF
03
06 00
7F C2
01 00
53 30
00 00
ON
BE EF
03
06 00
EF C3
01 00
53 30
01 00
Get
BE EF
03
06 00
4C C2
02 00
53 30
00 00
AUTO
KEYSTONE V
EXECUTE
Execute
BE EF
03
06 00
E5 D1
06 00
0D 20
00 00
KEYSTONE V
Get
BE EF
03
06 00
B9 D3
02 00
07 20
00 00
Increment
BE EF
03
06 00
DF D3
04 00
07 20
00 00
Decrement
BE EF
03
06 00
0E D2
05 00
07 20
00 00
KEYSTONE V
Reset
Execute
BE EF
03
06 00
08 D0
06 00
0C 70
00 00
AUTO ECO
MODE
Set
OFF
BE EF
03
06 00
FB 27
01 00
10 33
00 00
ON
BE EF
03
06 00
6B 26
01 00
10 33
01 00
Get
BE EF
03
06 00
C8 27
02 00
10 33
00 00
ECO MODE
Set
NORMAL
BE EF
03
06 00
3B 23
01 00
00 33
00 00
ECO
BE EF
03
06 00
AB 22
01 00
00 33
01 00
Get
BE EF
03
06 00
08 23
02 00
00 33
00 00
MIRROR
Set
NORMAL
BE EF
03
06 00
C7 D2
01 00
01 30
00 00
H:INVERT
BE EF
03
06 00
57 D3
01 00
01 30
01 00
V:INVERT
BE EF
03
06 00
A7 D3
01 00
01 30
02 00
H&V:INVERT
BE EF
03
06 00
37 D2
01 00
01 30
03 00
Get
BE EF
03
06 00
F4 D2
02 00
01 30
00 00
STANDBY
MODE
Set
NORMAL
BE EF
03
06 00
D6 D2
01 00
01 60
00 00
SAVING
BE EF
03
06 00
46 D3
01 00
01 60
01 00
Get
BE EF
03
06 00
E5 D2
02 00
01 60
00 00
MONITOR OUT -
COMPUTER IN1
Set
COMPUTER IN1
BE EF
03
06 00
3E F4
01 00
B0 20
00 00
OFF
BE EF
03
06 00
CE B5
01 00
B0 20
FF 00
Get
BE EF
03
06 00
0D F4
02 00
B0 20
00 00
MONITOR OUT -
COMPUTER IN2
Set
COMPUTER IN2
BE EF
03
06 00
CE F7
01 00
B4 20
04 00
OFF
BE EF
03
06 00
FE B4
01 00
B4 20
FF 00
Get
BE EF
03
06 00
3D F5
02 00
B4 20
00 00