23
ENGLISH
The status of signal reception is checked automatically and the result is displayed on the
screen.
Status
Display
Example
Signals are received
normally.
•The input terminal and the
horizontal and vertical frequencies
are displayed in a guidance image.
A sync signal could not be
detected.
❋
Also includes the status
of the VESA-DPMS sync
signal.
•The guidance message “POWER
SAVE” is displayed for about 5
seconds.
•In the event of continued absence of
a sync signal, the power indicating
lamp flickers and the monitor enters
power save mode.
The input signal does not
meet display specifications
or erratic.
•Displays OUT OF FREQUENCY.
and the Guide. (After 5 sec. have
elapsed, the display darkens and
display continues until the correct
signal is received.)
Eithe VIDEO1 or VIDEO2 is displayed
on VIDEO input.
The Easy Menu shown to the right will be displayed when the
SELECT button is used to select DISPLAY and moreover
DISPLAY INT is selected from the On-screen Display
System Easy Menu during RGB1/RGB2 input. If the
key (select Yes) of the SELECT button is pressed at this time, the user adjustment values in the
table below for the signal currently being received will be deleted and the factory settings will
be restored.
Pressing the
key (select No) cancels deletion and returns the DISPLAY menu.
INITIALIZE?
YES NO
Horizontal position
H.POSITION
Vertical position
V.POSITION
Dot clock frequency
CLOCK
16
Dot clock phase
PHASE
DISPLAY menu item
RGB1 [D-SUB]
H : 46.5kHz, V : 60Hz
POWER SAVE
OUT OF FREQUENCY.
28
30
Reset (Settings Initialization)
Signal Check