Hit-Not DDAC Series Скачать руководство пользователя страница 1

U-Bolt Assembly

Long Axis of 
Generator 
should run 

parallel to 
long axis of 

vehicle as 
shown

St

ep

 2

St

ep

 3

St

ep

 4

St

ep

 5

St

ep

 6

St

ep

 7

St

ep

 8

Install Generator

Warning Module Connections

Install Warning Module

Making the Connection to the 

Generator

Cab Silencer

DDAC Proximity Detection System 

Installation Guide

(DDAC-PDS-SYS)

Install the Generator on top of 
the overhead guard and at least 

4” from the frame. 

It should be 

as far from the strobe light as 
possible.

Use the U-Bolts to 

secure the Generator to the 
overhead guard.

4 i

n.

Connect Warning Module (Plug) to Generator (Receptacle).

(For weathershield mounts the connection is already made      

inside the weathershield)

Connection to generator 

should be pointed up

In order to avoid battery drain while the 
vehicle is off, connect Cab Silencer to a 

switched and fused (5A min) circuit. 

Place the Cab Silencer within 21” of the 
Operator’s PAD 

AND

4ft away from the 

generator. The best location is behind the 
operators seat. For Mounting Locations 

Diagram, see page 4.

The Cab Silencer may blind the CAM if installed 
on the overhead guard

.

www.hitnot.com

Place magnet side of the Warning Module 

to the frame of the forklift where it can be 

seen and heard by the operator.  

An optional Auxiliary Light ( Light 

Only Warning Module) can be 

connected to the Generator to 

provide an additional visual alert.

1/7/2020

DDAC20040rev3.6

All adjustments in Steps 7-13 need 

to be done by a professional.

Ground

12-15Vdc

Silent Zone Adjust

Factory set to ~21 in.

To decrease the size, unscrew the 

cap from the Cab Silencer.

Activate a PAD and turn on truck.

Using a 3/32” slotted screwdriver, 

turn the Pot until the PAD silences at 
the desired location.

Replace cap.

St

ep

 1

Average 
Current:0.5A 

Peak Surge 

Current: 15A 

Making the connection 

to machine power

Connect to a switched and fused (10A min) 

circuit. 

Ground

12-15V

dc

The cable 

exiting the 

warning 

module 

with the 

connector 

goes to the 

Generator

The cable 

exiting the 

warning 

module 

with the 

bare wires 

goes to the 

machine for 

power

Note: Cable Ties included for attaching the 
cables to the frame of the machine. 

Volume Adjust 

using Range Adjust Tool 

The clear plastic cover on the Warning Module can 
be turned to reduce the sound.

If the sound still needs to be reduced, utilize the 

range adjust tool (Contact FEP). 

Ensure all other MFGs and PADs within 70ft 
are off. Power on the range adjust tool 

within 4ft of MFG.  The warning module will 
sound.  Press the up switch to increase the 
volume of the warning module and the 

down switch to decrease the volume of the 
warning module. 

DO NOT APPLY VOLTAGE TO THE INCORRECT WIRES, IT MAY 

RESULT IN HARDWARE DAMAGE.

(This step shows mounting using the rear mount for other 

mounting options see page three)

Ensure the Silent Zone does not 
extend outside of the vehicle

1