Hisense HAWV9KR Скачать руководство пользователя страница 1

Содержание HAWV9KR

Страница 1: ...r 1nl D ir lUJ D Thank you very much for purchasing this Air Conditioner Please read this use and installation instructions carefully before installing and using this appliance and keep this manual fo...

Страница 2: ...13 Identification of parts 14 Indoor unit 14 Outdoor unit 14 Display introduction 15 Remote controller 16 Operation instructions Operation modes 18 Airflow direction control SMART mode SUPER mode 19 2...

Страница 3: ...elect the installation locations 26 Indoor unit installation 27 Connecting of the cable 29 Wiring diagram 30 Outdoor unit installation 31 Air purging 32 Maintenance 33 Protection 34 Troubleshooting 35...

Страница 4: ...that are intended to be permanently connected to fixed wiring and have a leakage current that may exceed 10 mA shall state that the installation of a residual current device RCD having a rated residu...

Страница 5: ...the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 19 The appliance shall be installed in accordance with national wiring regulations 20 Servicing shall only...

Страница 6: ...roller can also be used Back light function of Remote Control optionaQ Hold down any button on remote control to activate the back light It automatically shuts off 10 seconds later Note Back lightis a...

Страница 7: ...ers and stove electric shock or afire break out due to insufficient contact Do not use the ower supply circuit reaker r pull offt_he plug Do not touch the operation buttons to Urn 1t offdunng operatio...

Страница 8: ...on on servicing 6 1 Checks to the area Prior to beginning work on systems containing flammable refrigerants safety checks are necessary to ensure that the risk of ignition is minimised For repair to t...

Страница 9: ...to the system or conducting any hot work A degree of ventilation shall continue during the period that the work is carried out The ventilation should safely disperse any released refrigerant and prefe...

Страница 10: ...solutely necessary to have an electrical supply to equipment during servicing then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially h...

Страница 11: ...shall be calibrated in a refrigerant free area Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used Leak detection equipment shall be set at a percen...

Страница 12: ...ements shall be followed Ensure that contamination of different refrigerants does not occur when using charging equipment Hoses or lines shall be as short as possible to minimise the amount of refrige...

Страница 13: ...solation valves on the equipment are closed off k Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked 15 Labelling Equipment shall be la...

Страница 14: ...compressor to the suppliers Only electric heating to the compressor body shall be employed to accelerate this process When oil is drained from a system it shall be carried out safely it CAUTION When m...

Страница 15: ...all be c mplianced with national gas regulations The maximum refrigerant charge amount is 2 5 kg The specific refrigerant charge is based on the nameplate of the outdoor unit Mechanical c nnect rs use...

Страница 16: ...should be over 50mm Distance from the obstacle should be over 3000mm Air intake distance from the wall should be over250mm Distance from floor should be over 2500mm 13 should be over 50mm Air intake...

Страница 17: ...Air Filter i Remote Controller Outdoor unit The figures in this manual are based on the extemal view ofa standard model Consequently the shape may dlll erfrom that ofthe aircondlUoneryou have selecte...

Страница 18: ...in order to reset the display optional It displays set humidity in humidity mode optional Running indicator 0 O 00 f It lights up when the AC is running It flashes during defrosting Timer indicator 0...

Страница 19: ......

Страница 20: ...aveNIKted remote conlrcller holderfixing How to Use remote controller mounting To operate the room air conditioner aim the remote controller to the signal receptor The remote controllerwill operate th...

Страница 21: ...fectinin this can SoJHmodels IWt h as commercialairt Ondi6ontwproducts onlyhaw the third gaerspeed Auto Auto High High Medium Low Low Setting temperature II OJ lfS Press I button once Range ofavallabl...

Страница 22: ...nit dE2 PRESS oN I SUPER J SWING 1 TIMER J Operation mode Direction of airflow ___ __ _ __ COOLING DRY horizontal HEATING downward FAN ONLY 1 0F Y The direction ofairflow can be also adjusted to your...

Страница 23: ...dels such as wall mounted air conditioners and some floor standing air conditioners their operation mode and set temperature should be determined based on the indoor temperature Operation mode and tem...

Страница 24: ...olledautom tlct llyIn SMARTmode However Forthe on off you can choose from 2to 2 for somemode ayou can choose from 7 to 7 for the inverleryoucan choa e from 7to 7 ifyoustillfeel uncomfortllble What you...

Страница 25: ...he set temperature automatically to 30 C 86 F How to cancel SUPER mode Press SUPER MODE FAN SPEED ON OFF QUIET or SLEEP button Result Note The display return to the original mode Escape from SUPER mod...

Страница 26: ...ed on LCD press the ON TIMER button and confinn it Result A beep can be heard ON stops flashing The TIMER indicator on the indoor unit lights up invalid for multi system 4 After the set timer displaye...

Страница 27: ...bout 5 seconds once again Result IFEEL function will be shunted off I DIMMER button Howtosetthe DIMMER 1 Press the DIMMER button to tum off the light and the display in the unit Note When thetight Is...

Страница 28: ...hen keeps steady Note In r oollngmode If _ frlmPfllllfunt a 26 C 79 F or ban nttamp11T11tun will not change Note HNtlng la NOTavaflablsforcooling onlyairconditioner How to cancel SLEEP mode Press any...

Страница 29: ...flammable gas could leak Keep the required distance apart from the wall The pipe length between indoor and outdoor unit should be not more than 5 meters in factory default status but it can go up to...

Страница 30: ......

Страница 31: ...pe fixer to the slot Base B Press to hook the pipe fixer onto the base Piping Connection a Before unsc rewing the big and the small sealing caps press the small sealing cap with the finger until the e...

Страница 32: ...ver fail to have an individual power circuit specifically for the air conditioner As for the method of wiring refer to the circuit diagram posted on the inside of the access door 2 Comfirm that the ca...

Страница 33: ...o terminals all supply circuits must be disconnected Make sure that the color of the wires in the outdoor unit and terminal No are the same as those ofthe indoor unit Indoor unit Terminal Outdoor unit...

Страница 34: ...ort and rubber washer to the chassis ofthe outdoor unit then connect a drain hose to the port as the right figure demonstrates 2 Install and Fix Outdoor Unit Fix with bolts and nuts tightly on a flat...

Страница 35: ...es 1 Unscrew and remove caps from 2 and 3 way valves 2 Unscrew and remove cap from service valve 3 Connect vacuum pump flexible hose to the service valve Connect to outdoor unit 4 Start vacuum pump fo...

Страница 36: ...Close the front panel again Clean the airfilter every two weeks Ifthe airconditioner operates In an extremely dusty environment 0 Grasp position a and pull outward to remove the front panel Never use...

Страница 37: ...lace where the air discharged and the operation noise would not annoy your neighbors Do not place any obstacles in front of the air outlet of the outdoor unit lest ii increases the noise level Feature...

Страница 38: ...er supply and connect back 2 3 seconds later Does not operate immediately don run Changing mode during operation 3 minutes will delay Peculiar odor A sound of flowing water I This odor may come from a...