Thank you very much for purchasing this Air Conditioner. Please
read this use and installation instructions carefully before installing
and using this appliance and keep this manual for future reference.
Страница 1: ...Thank you very much for purchasing this Air Conditioner Please read this use and installation instructions carefully before installing and using this appliance and keep this manual for future reference ...
Страница 2: ...he envirionment 2 Identification of parts 4 Maintenance 15 Protection 16 Troubleshooting 17 Select the installation locations 19 Indoor unit installation 20 Outdoor unit installation 24 Installation diagram 18 Air purging 24 Wiring diagram 23 Installation instructions 18 CLOCK button 11 Contents Operation modes 8 Operation instructions 7 1 safety instructions Note 2 DIMMER mode 13 IFEEL mode 13 EC...
Страница 3: ...fficiency of the air conditioner if the distance longer than that length This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play wi...
Страница 4: ...02 96 EC Waste Electrical and Electronic Equipment WEEE This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection...
Страница 5: ...he power supply cord be broken An electric shock or fire is probably caused by a broken power supply cord Never insert a stick or similar obstacle to the unit Since the fan rotates at high speed this may cause an injury Do not repair the appliance by yourself If this is done incorrectly it may cause an electric shock etc Turn off the appliance by remote control firstly before cutting off power sup...
Страница 6: ...or unit ON OF F M O DE SM AR T Q UI ET DI M M ER EC ON OM Y FE EL SU PE R FAN SPE ED CL O CK TI M ER ON TI ME R OF F SL EE P TE MP TE MP Air Intake Air Intake Air Outlet Air Outlet Louver Vertical Adjustment Louver Horizontal Adjustment Air Filter Remote Controller Connection Cord Pipes and Power Drain Hose Front Panel Note Condensate water drains at COOLING or DRY operation Emergency Panel Displa...
Страница 7: ... lights up when the compressor is on Display set temperature It shows FC after 200 hours of usage as reminder to clean the filter After filter cleaning press the filter reset button located on the indoor unit behind the front panel in order to reset the display optional Temperature indicator 1 2 3 4 5 9 VG VL series Signal Receptor Timer Comp Run Sleep Super indicator It lights up in super mode 2 ...
Страница 8: ...Display introduction 5 The symbols may be different from these models but the functions are similar 1 2 3 4 5 9 VT series SE series 1 2 3 4 5 9 SF series 1 2 3 4 5 9 ...
Страница 9: ...play introduction The symbols may be different from these models but the functions are similar 5 1 2 3 4 5 9 Timer Comp Run Sleep UL series UQ series UP series 9 Timer Comp Run Sleep 1 2 3 4 5 1 2 3 4 5 9 ...
Страница 10: ...Display introduction The symbols may be different from these models but the functions are similar 5 NT series VQ TE TF series 2 3 4 1 2 3 4 5 4 3 2 1 2 3 4 5 9 NS series 9 9 ...
Страница 11: ...Display introduction The symbols may be different from these models but the functions are similar 5 VM series 9 2 2 3 4 4 1 5 NM series NK series 2 3 5 4 1 9 6 4 2 3 9 TA TC series 2 3 9 1 ...
Страница 12: ...m these models but the functions are similar 5 Display introduction Emergency button 10 ON OFF VC series 1 2 3 4 5 Timer Comp Run Sleep 9 TD TG SA series 9 1 2 3 4 10 To let the AC run or stop by pressing the button SC series 7 2 8 1 ...
Страница 13: ... Remote controller 5 TEMP Used to adjust the room temperature and the timer also real time DIMMER When you press this button all the display of indoor unit will be closed Press any button to resume display SWING Used to stop or start vertical adjustment louver swinging and set the desired up downairflow direction Used to stop or start Horizontal adjustment louver swinging and set the desired left ...
Страница 14: ... remote controller holder is an optional part 7 To operate the room air conditioner aim the remote controller to the signal receptor The remote controller will operate the air conditioner at a distance of up to 7m whenpointing at signal receptor of indoor unit Remote controller Note Use 2 LR03 AAA 1 5volt batteries Do not use rechargeable batteries Replace batteries with new ones of the same type ...
Страница 15: ...pliance During heating operation air flow is not discharged at the beginning After 2 5 minutes the air flow will be discharged until temperature of indoor heat exchanger rises 16 30 Range of available set temperature HEATING COOLING DRY 7 7 unable to set FAN ONLY 8 Operation modes Note Heating mode is NOT available for cooling only models Note Remote controller At Dry mode a decrease or rise of up...
Страница 16: ...estore power supply again It is better not to let the vertical adjustment louver tilt downward for a long time at COOLING or DRY mode to prevent condensed water from dripping Heating mode is only available for heat pump models Airflow direction control Press button once Press button again A B The louvers swing to a suitable angle as desired The vertical adjustment louver will swing up and down aut...
Страница 17: ...eat pump models Cooling only models Indoor temperature Target temperature 23 or below 26 Over 26 23 26 Operation mode FAN ONLY DRY Room temperature decrease 2 after operate for 3 minutes COOLING FAN SPEED How to set SMART mode Press the button SMART Result Enters SMART mode fuzzy logic operation directly regardless of the unit is on or off Temperature and fan speed are automatically set based on t...
Страница 18: ...CD 1 2 CLOCK CLOCK 3 The real time is set How to set SUPER mode Press button at the cool mode Result At high fan speed the set temperature automatically to 16 SUPER Press button at the heat mode Result At auto fan speed the set temperature automatically to 30 How to cancel SUPER mode 11 Press SUPER MODE FAN ON OFF SLEEP or TEMPERATURE SETTING button Result The display return to the original mode I...
Страница 19: ...ress the or button TEMP TEMP Once to increase or decrease the time setting by 1 minute One and a half seconds to increase or decrease the time setting by 10 minute For a longer time to increase or decrease the time by 1 hour A beep can be heard The TIMER indicator on the indoor unit lights up ON stops flashing When your desired time displayed on LCD press the TIMER ON button and confirm it TIMER O...
Страница 20: ...button to turn off the light and the display in the unit Note When the light is off receive signal will turn on the light again How to set the DIMMER Press the button for about 5 seconds How to cancel IFEEL mode Result The transmit signal in the display will disappear the IFEEL function will be shunted off i FEEL 1th 2th How to set IFEEL mode Press the button Result IFEEL function will be started ...
Страница 21: ...ase Set temperature will decrease by 2 if the appliance operates in heating mode for 2 hours constantly rise by 1 after 6 hours then rise by 1 after 7 hours SLEEP mode 2 Set temperature will rise by 1 if the appliance operates in cooling hours then decrease by 2 after 6 hours decrease by 1 after 7 hours mode for 1 hour rise by 2 after 2 Set temperature will decrease by 2 if the appliance operates ...
Страница 22: ...l and shut the front panel Reinstall and shut the front panel by pressing position b downward If the dirt is conspicuous wash it with a solution of detergent in lukewarm water After cleaning dry well in shade Clean the air filter every two weeks if the air conditioner operates in an extremely dusty environment Stop the appliance and remove the air filter 1 2 3 1 Open the front panel 2 Press the ha...
Страница 23: ...ot place any obstacles in front of the air outlet of the outdoor unit lest it increases the noise level Features of protector If all operation has stopped press ON OFF button again to restart Timer should be set again if it has been canceled The protective device will work at following cases Restarting the unit at once after operation stops or changing mode during operation you need to wait for 3 ...
Страница 24: ...operly plugged If batteries in the remote controller exhausted Please wait for 3 minutes and start again protector device may be preventing unit to work If strong interference from excessive static electricity discharge power supply voltage abnormality presents operation will be abnormal At this time disconnect from the power supply and connect back 2 3 seconds later Changing mode during operation...
Страница 25: ...outlet distance from the wall should be over 500mm should be over 200 mm should be over 50mm should be over 2500mm should be over 250mm Installation must be performed in accordance with the national wiring standards by authorized personnel only Above figure is only a simple presentation of the unit it may not match the external appearance of the unit you purchased Installation instructions Install...
Страница 26: ...cording to the installation diagram on previous page Where the air filter can be easily removed Keep the unit and remote controller 1m or more apart from television radio etc keep as far as possible from fluorescent lamps Do not put anything near the air inlet to obstruct it from air absorption Install on a wall that is strong enough to bear the weight of the unit Install in a place that will not ...
Страница 27: ...ut the piping liquid and gas pipe and cables through the wall hole from outside or put them through from inside after indoor piping and cables connection is complete to connect to the outdoor unit Decide whether to saw the unloading piece off in accordance with the piping direction as shown below 3 Indoor Unit Piping Installation Install a sleeve through the wall hole to keep the wall tidy and cle...
Страница 28: ...nto the base Base Base Base Piping fixer Piping fixer Hook here Insert here drain hose drain hose large pipe large pipe small pipe small pipe Small pipe Large pipe Thermal insulation tube Power cord Drain hose prepared by user b Pre tighten them with fingers at first then use the wrenches a Connect indoor unit pipes with two wrenches Pay special attention to the allowed torque as shown below to pr...
Страница 29: ...s door 2 Comfirm that the cable thickness is as specified in the power source specification 3 Check the wires and make sure that they are all tightly fastened after cable connection 4 Be sure to install an earth leakage circuit breaker in wet or moist areas The figures in this manual are based on the external view of a standard model Consequently the shape may differ from that of the air condition...
Страница 30: ...he outdoor unit with a circuit breaker For 9K 12K 18K 22K 24K 30K models the power supply is connected from the indoor unit with a circuit breaker Outdoor unit Indoor unit Terminal Terminal Powerconnectingcord Blue Blue Black 1 L 1 L 2 N 2 N 4 SI 4 SI Black BN BU YE GN RY1 ACIN L CN10 ACIN N Brown Indoorunitcontrolboard Evaporator YE GN YE GN 3 3 Brown Power supply BN BU YE GN RY1 ACIN L CN10 ACIN...
Страница 31: ...ll the drain port and rubber washer to the chassis of the outdoor unit then connect a drain hose to the port as the right figure demonstrates The air which contains moisture remaining in the refrigeration cycle may cause a malfunction on the compressor After connecting the indoor and outdoor units release air and moisture from the refrigerant cycle using a vacuum pump as shown below 24 Installatio...
Страница 32: ...d soap or an electronic leak detector 7 Turn 2 and 3 way valves stem to fully close the valves Disconnect the flexible vacuum pump hose 8 Replace and tighten all valve caps 5 With vacuum pump still running close the low pressure knob on vacuum pump manifold Then stop the vacuum pump 2 Unscrew and remove cap from service valve 3 Connect vacuum pump flexible hose to the service valve How to Purge Ai...
Страница 33: ...Version No 1805210 03 ...