Hisense AS-09HR4SVCUH Скачать руководство пользователя страница 1

 

 

CLIMATIZZATORE D’ARIA 
 
 
 
 
 
 
 
 

 
Hisense Corporation 

 

Serie Classical on off

 

Содержание AS-09HR4SVCUH

Страница 1: ...CLIMATIZZATORE D ARIA Hisense Corporation Serie Classical on off...

Страница 2: ...dei rifiuti solidi urbani Gli apparecchi dimessi devono essere raccolti separatamente per ottimizzare il recupero ed il riciclaggio dei materiali che li compongono per ottenere un importante risparmio...

Страница 3: ...del filtro Filter cleaning 13 5 Operazioni e prestazioni Operations and performances 14 6 Problemi e loro cause Problems and causes 6 1 Generale General 15 6 2 Problemi relativi al telecomando Concer...

Страница 4: ......

Страница 5: ...5 secondi la funzione di auto restart viene disattivata viene emesso un suono e il cli matizzatore rimane in stand by Before using the air conditioner be sure to check and preset the following Remote...

Страница 6: ...2...

Страница 7: ...isk of serious electrical shock never sprinkle or spill water or liquid on the unit ATTENZIONE Ventilare la stanza ogni tanto mentre il condizionatore in funzione specialmente se ci sono altre apparec...

Страница 8: ...tion Mantenere la temperatura della stanza a un livello confortevole Maintain room temperature at a comfortable level Pulizia del filtro dell aria Un filtro dell aria intasato riduce la poten za di ra...

Страница 9: ...and power connection cord Scarico condensa Drain Ingresso aria Air inlet Griglia frontale Front panel Pannello di controllo Control panel Pannello display Display panel Uscita aria Air outflow Filtri...

Страница 10: ...COMPRESSORE Si illumina quando il compressore in funzionamento 1 TIMER Indicator This indicator illuminates when TIMER is set ON OFF 2 OPERATION Indicator This indicator flashes after power is on ond...

Страница 11: ...slect the operation mode 3 Fan BUTTON Used to select fan speed in sequence auto high medium or low 4 5 ROOM TEMPERATURE SETTING BUTTONS Used to adjust the room temperature and the timer also real tim...

Страница 12: ...lle batterie facendo scivolare nella direzione della frec cia 2 Richiudere il coperchio del vano batterie NOTE Non mettere insieme batterie nuove con vecchie o batterie di tipo differente Ci pu essere...

Страница 13: ...ngle as you like Swing airflow Pressing SWING button once the vertical adjust ment louver will swing up and down automatically Desired direction airflow Pressing the SWING button again when the lou ve...

Страница 14: ...still feel uncomfortable 3 5 CLOCK button To adjust the real time press CLOCK button then use and buttons to get the correct time press CLOCK button again the real time is set Indoor fan speed alterna...

Страница 15: ...u essere trasmesso in modo corretto pu verificarsi un ritardo di 15 minuti TIMER mode TIMER ON OFF push these buttons to set the timer programming as wished in order to switch on an off the air condit...

Страница 16: ...SU PE R 3 7 Modalit SLEEP La modalit SONNO SLEEP pu essere usata in modalit di riscaldamento o di RAFFREDDAMENTO Questa funzione utile per un ambiente pi confortevole quando si va a dormire dormire In...

Страница 17: ...ove batteries from remote controller Controlli prima dell accensione Checks before operation AVVERTENZE Controllare che le connessioni a cartella non siano rotte o disconnesse Controllare che il filtr...

Страница 18: ...uando si surriscalder lo scambiatore del calore dell unit interna La lampadina PRE DEF accesa durante questi intervalli indicando l operazione di preriscaldamento Controllo dell aria calda Quando la t...

Страница 19: ...mote controller Lighting or a car wireless telephone operating nearby may cause the unit to malfunction Disconnect the unit with the power and then connect the unit with the power again Push the ON OF...

Страница 20: ...a All accensione si nota un rumore dovuto all apertura delle alette Low noise of the air conditioner May be some ss sound caused by the flowing of refrigerant May be some zz sound caused by the natura...

Страница 21: ...ione il climatizzatore si attiva auto maticamente e l indicatore si spegne When the time set to start the air conditio ner is reached the air conditioner will automatically start and the appropriate i...

Страница 22: ...uthorized personnel When installing the air conditioner wear suitable accident preventing garments such as goggIes gauntIets etc Work in absolute safety in clean surroundings free from impediments whe...

Страница 23: ...sunlight Position the unit in a place where condensate can be easily discharged and from whence the pipes can be easily connected to the outdoor unit Position the unit in compliance with a minimum di...

Страница 24: ...Install the outdoor unit in a sufficient ventilated sheltered place protected from the rain and direct sunlight Make sure that the point in which the unit is positioned is able to bearits weight and...

Страница 25: ...ters Scelta delle tubazioni I tubi del liquido e del gas devono essere isolati termicamente e singolarmente Utilizzare un set di tubo per frigoristi reperibile in commercio e rivestito di materiale ad...

Страница 26: ...n the left right downwards sides of the plastic basement of the indoor unit Ancoraggio della piastra di fissaggio La piastra di fissaggio deve essere ancorata e allineata sia orizzontalmente che verti...

Страница 27: ...rough the drain hose of the indoor unit without any leakage and goes out the drain exit 4 Never turn the nuts off from the pipe ends before linking the pipe units Tubo di drenaggio Drain pipe Unire Bi...

Страница 28: ...1L 3L 3L 2L 2L N N L L Alimentazione Power supply Blu Blue G i a l l o v e r d e Y e l l o w G r e e n Black Brown Violet Black Orange Gray Brown Blu Blue Marrone Brown Orange Gray Violet Black Black...

Страница 29: ...ue Reccomendations when the pipes are installed Unwind the pipe in the direction in which it was wound see fig 13 Wrap the two pipes together with tape before passing them through the holes in the wal...

Страница 30: ...nel modo corretto e che tutti i cablaggi necessari al col laudo siano stati effettuati Rimuovere i cap pucci delle valvole di servizio sia dai lati gas che liquido sul gruppo esterno Prendere nota del...

Страница 31: ...lvola a 2 vie girate lo stelo della valvola in senso antiorario di circa 90 aspettate 2 o 3 secondi circa e chiudetela Applicare l acqua saponata o liquido detergente neutro sui collegamenti dell unit...

Страница 32: ...erante nell unit esterna open the valve Loosen the charge hose connected to the gas side service port slightly to release the pressure then remove the hose Replace the flare nut and its bonnet on the...

Страница 33: ...nto Collegamenti corretti dei cavi e delle tubazioni Perdite di gas dai collega menti delle tubazioni Valvole aperte completa mente I cavi di collegamentotra unit esterna ed interna sono inseriti in m...

Страница 34: ...5 5 8 6 9 80 Prestazioni EER kW kW 3 22 3 21 3 21 3 21 COP kW kW 3 62 3 21 3 61 3 61 Classe di efficienza energetica Raffreddamento A A A A Riscaldamento A C A A Deumidificazione lt h 0 9 1 5 2 2 5 Po...

Страница 35: ...ndensatore compressore COMPRESSOR RELAY Rel compressore DEFROST INTERFACE Sensore sbrinamento DISPLAY BOARD Scheda display FAN CAPACITOR Condensatore ventilatore FAN MOTOR Ventilatore unit esterna HEA...

Страница 36: ...GREEN Y G Giallo Verde BLUE Blu GREEN Verde ORANGE Arancione RED Rosso WHITE Bianco YELLOW Giallo COMPRESSOR Compressore COMPRESSOR CAPACITOR Condensatore compressore COMPRESSOR RELAY Rel compressore...

Страница 37: ...LOW GREEN Y G Giallo Verde BLUE Blu GREEN Verde ORANGE Arancione RED Rosso WHITE Bianco YELLOW Giallo COMPRESSOR Compressore COMPRESSOR CAPACITOR Condensatore compressore COMPRESSOR RELAY Rel compress...

Страница 38: ...service clima hisenseitalia it Hisense Italy Srl Corso sommeiller 32 10128 Torino Italy Tel 39 011 011500916 Fax 39 011 0115183200 e mail service clima hisenseitalia it www hisenseitalia it 1343549 01...

Отзывы: