Specifications
32
ML23.8 User Manual, 99182A, April 2022
Electrical
Monitor Input
• AC power input – 100 to 240 VAC, 0�6/0�3 A, 60/50 Hz
• DC power input – 10�8 to 26�4 VDC, 2�3 to 0�9 A, Class 2 or
SELV/LPS
Power Consumption
~ 27 W
Power Consumption
(Standby mode)
< 2 W
Compliances and Certifications
Electrical
•
UL 62368-1/cUL Recognized Component (File No. E212889)
• UL 508A Listed (File No� E318630)
• FCC Class A
•
CAN ICES-3A/NMB-3A Issue 07
NOTE:
DC power must use shielded DC input cable
• CE
NOTE:
DC power must use shielded DC input cable
• UKCA
NOTE:
DC power must use shielded DC input cable
•
NOM (Registration No. NOM-019-SCFI-1998)
Environmental
WEEE (Registration No. WEE/DJ1859ZX for UK only)
Enclosure
UL 50E (File No� E318630)
Hazardous Location
UL Rated for Hazardous Locations: Industrial Control Equipment
for Hazardous Location: Listed for Class I, Division 2 for Groups
A, B, C, and D; Class II, Division 2 for Groups F and G; Class
III; Temp Code T5 (File No� E328481) per UL121201-2017 and
CAN/CSA C22�2 No� 213-17