background image

Description and operating instructions
Industrial Rail Switch

SPIDER xTX(/xFX)

The Rail Switches

– SPIDER 5TX
– SPIDER 8TX
– SPIDER 4TX/1FX

in short SPIDER xTX(/xFX), are switches
especially designed for use in industrial
environments. It supports ETHERNET
10 MBit/s and Fast ETHERNET 100 MBit/s.

The devices support switched ETHERNET
networks in accordance with IEEE standard
802.3 or 802.3u using copper and fiber optic
technology. The devices are plugged onto
the standard bar.

The SPIDER 5TX devices have five 10/100
MBit/s twisted pair ports (RJ45 connectors).
It is possible to connect up to five data
terminal equipments or other network
segments to the TP ports using twisted pair
cabling. 

The SPIDER 8TX devices have eight 10/100
MBit/s twisted pair ports (RJ45 connectors).
It is possible to connect up to eight data
terminal equipments or other network
segments to the TP ports using twisted pair
cabling. 

The SPIDER 4TX/1FX devices have four
10/100 MBit/s twisted pair ports (RJ45
connectors) and one 100 MBit/s fiber optic
port (100BASE-FX, Duplex SC connector). It
is possible to connect up to four data
terminal equipments or other network
segments to the TP ports using twisted pair
cabling. One further DTE or optical network
component can be connected to the fiber
port.

The TP ports support autonegotiation, auto-
polarity and autocrossing.

The fiber optic port of the SPIDER 4TX/1FX
supports full duplex (FDX).

SPIDER xTX/xFX

SPIDER 5TX

SPIDER 4TX/1FX

P

x

P

x

P

x

DA/STAT

SPIDER 8TX

Содержание SPIDER 4TX/1FX

Страница 1: ...nts to the TP ports using twisted pair cabling The SPIDER 8TX devices have eight 10 100 MBit s twisted pair ports RJ45 connectors It is possible to connect up to eight data terminal equipments or other network segments to the TP ports using twisted pair cabling The SPIDER 4TX 1FX devices have four 10 100 MBit s twisted pair ports RJ45 connectors and one 100 MBit s fiber optic port 100BASE FX Duple...

Страница 2: ... in the catalog and technical description and only in conjunction with external devices and components recommen ded or approved by Hirschmann The product can only be operated correctly and safely if it is transpor ted stored installed and assembled properly and correctly Furthermore it must be operated and serviced carefully Safety Guidelines Power Supply Switch the basic devices on only when the ...

Страница 3: ...d devices or systems in accordance with current safety enginee ring standards trained or directed in the care and use of appropriate safety equipment in accor dance with the current standards of safety engineering trained in providing first aid General Safety Instructions This device is electrically operated Adhere strictly to the safety requirements relating to voltages applied to the device as d...

Страница 4: ...oes not transmit any data to a TP segment from which it does not receive a link test pulse Note A non occupied interface is assessed as a line interrupt The TP line to terminal equipment which is switched off is likewise assessed as a line interrupt as the de energised bus coupler cannot transmit link test pulses Auto polarity exchange If the receive line pair is incorrectly connec ted RD and RD s...

Страница 5: ...der the low light level If Far End Fault is re ceived the link stays inactive DA STAT LED dark 1 4 FURTHER FUNCTIONS AND FEATURES Reset The SPIDER xTX xFX will be reset by the following action input voltages fall below a threshold After a reset the following action is carried through initialization 1 5 DISPLAY ELEMENTS Equipment status These LEDs provide information about statuses which affect the...

Страница 6: ...tact discharge EN 61000 4 2 Test level 3 Air discharge EN 61000 4 2 Test level 3 Electromagnetic fields EN 61000 4 3 Test level 3 Fast transients EN 61000 4 4 Test level 3 Surge voltage symmetrical EN 61000 4 5 Test level 2 Surge voltage asymmetrical EN 61000 4 5 Test level 3 Cable based RF faults EN 61000 4 6 Test level 3 Fig 5 Assembling the SPIDER xTX xFX Fig 6 Dimensions 13 7 70 63 3 23 8 5 3 ...

Страница 7: ... 100 MBit s 1 FX Port Duplex SC connection 100 MBit s SPIDER 5TX 5 TP TX Ports RJ45 sockets 10 100 MBit s SPIDER 8TX 8 TP TX Ports RJ45 sockets 10 100 MBit s Displays Equipment status 1 x green LED P power supply voltage present Port status SPIDER 4TX 1FX 5 x green LEDs DA STAT data link status 4 x yellow LEDs 10 100 data rate SPIDER 5TX 5 x green LEDs DA STAT data link status 5 x yellow LEDs 10 1...

Отзывы: