background image

18

Installation OCTOPUS OS20/OS24 Unmanaged

Release 08 07/2015

1.4

Power supply

1.4.1

Supply voltage with the characteristic value A

A 5-pin M12  plug is available for the redundant supply to the device.

See “Devices featuring supply voltage with the characteristic value A” on 
page 22.

1.4.2

Supply voltage with the characteristic value F

A 5-pin 7/8" connector is available to supply the device with PoE redundantly.

See “Devices featuring supply voltage with the characteristic value F” on 
page 23.

1.4.3

Supply voltage with the characteristic value N

A 4-pin 7/8" connector is available to supply the device.

See “Devices featuring supply voltage with the characteristic value N” on 
page 24.

1.5

Ethernet ports

You can connect end devices and other segments to the device ports using 
twisted pair cables or optical fibers (F/O).
You find information on pin assigments for making patch cables here:

“Pin assignments” on page 20

1.5.1

10/100 Mbit/s twisted pair port

This port is designed as an 4-pin M12 socket.
The 10/100 Mbit/s twisted pair port offers you the ability to connect network 
components according to the IEEE 802.3 10BASE-T/100BASE-TX standard.
This port supports:

Autonegotiation 

Autopolarity 

Autocrossing

Delivery state: Autonegotiation activated
The socket housing is electrically connected with the device housing.

Note: 

Some of these ports also support Power over Ethernet (PoE).

See “10/100 Mbit/s PoE port” on page 19.

Содержание OS20-001000T5T5TAFUHB

Страница 1: ... P1 P2 x y OCTOPUS OS20 Unmanaged ETHERNET Switch Power N C P 1 2 3 4 N C Pin Function P Power 1 2 4 3 P 4 5 1 3 2 9 10 8 7 6 x y OCTOPUS OS20 Unmanaged ETHERNET Switch OS20 001000T5T5TNEUHB Power N C 1 2 3 4 5 P2 Pin Function P1 Power 4 5 1 2 3 P P1 4 5 1 3 2 9 10 8 7 6 PoE PoE P2 FAULT x y OCTOPUS OS24 Unmanaged ETHERNET Switch OS24 081000T5T5TFFUHB P Port 2 5 7 10 Power N C P 1 2 3 4 N C Pin Fu...

Страница 2: ...atures described here are binding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to the best of the company s knowledge Hirschmann reserves the right to change the contents of this document without prior notice Hirschmann can give no guarantee in respect of the correctness or accuracy of the informat...

Страница 3: ... ports 18 1 5 1 10 100 Mbit s twisted pair port 18 1 5 2 10 100 Mbit s PoE port 19 1 5 3 Pin assignments 20 1 6 Display elements 20 2 Installation 22 2 1 Checking the package contents 22 2 2 Connecting the connector for the supply voltage 22 2 2 1 Devices featuring supply voltage with the characteristic value A 22 2 2 2 Devices featuring supply voltage with the characteristic value F 23 2 2 3 Devi...

Страница 4: ...Installation OCTOPUS OS20 OS24 Unmanaged Release 08 07 2015 2 7 Connecting data cables 28 3 Monitoring the ambient air temperature 29 4 Maintenance and service 30 5 Technical data 31 A Further Support 38 ...

Страница 5: ...product only for the application cases described in the Hirschmann product information including this manual Operate the product only according to the technical specifications See Technical data on page 31 Connect to the product only components suitable for the requirements of the specific application case WARNING UNCONTROLLED MACHINE ACTIONS To avoid uncontrolled machine actions caused by data lo...

Страница 6: ...standards in safety technology Qualified personnel are aware of the dangers that exist in their work Qualified personnel are familiar with appropriate measures against these hazards in order to reduce the risk for themselves and others Qualified personnel receive training on a regular basis National and international safety regulations Verify that the electrical installation meets local or nationa...

Страница 7: ...fied relative humidity exclusively Install the device in a location where the climatic threshold values specified in the technical data are adhered to Make sure the environment does not heat the device Use the device in an environment with a maximum pollution degree that complies with the specifications in the technical data Relevant for use in North America Use this device solely in Class 2 Circu...

Страница 8: ... states with regard to electrical equipment to be used within specific voltage ranges 2004 108 EC EMC Directive of the European Parliament and the council for standardizing the regulations of member states with regard to electromagnetic compatibility In accordance with the above named EU directive s the EU conformity declaration will be at the disposal of the relevant authorities at the following ...

Страница 9: ...tions These requirements are designed to provide sufficient protection against interference when the device is being used in a business environment The device creates and uses high frequencies and can also radiate these frequencies If it is not installed and used in accordance with this operating manual it can cause radio transmission interference The use of this device in a residential area can a...

Страница 10: ...s Manual The Installation user manual contains a device description safety instructions a description of the display and the other information that you need to install the device Legend The symbols used in this manual have the following meanings Listing Work step Subheading ...

Страница 11: ...tworks that conform to the IEEE 802 3 standard in the line structure The devices work without a fan The 10 twisted pair ports are M12 sockets The twisted pair ports support Autocrossing Autonegotiation Autopolarity Mount the device on a level surface with four M5 screws The Hirschmann network components help you ensure continuous communication across all levels of the company Connect your devices ...

Страница 12: ...atalog www e catalog beldensolutions com on the web page of the device Item Product characteristic Product code Value for the characteristic 1 4 Product OS20 Octopus device with Fast Ethernet ports without PoE ports OS24 Octopus device with Fast Ethernet ports with PoE ports 5 hyphen 6 7 Number Special ports 00 0 PoE ports 08 8 PoE ports 8 9 Number 100 Mbit s ports 10 10 100 Mbit s ports 10 11 Num...

Страница 13: ...e F on page 23 Voltage range DC incl maximum tolerances 16 8 V 60 V Connection type 7 8 connectors 5 pin N Rated voltage range DC 72 V 110 V Voltage range DC incl maximum tolerances 50 4 V 138 V Connection type 7 8 connectors 4 pin 18 Certifications E UL Railway along track Railway train F UL Railway along track Railway train Germanischer Lloyd E1 19 Software variant U Unmanaged 20 Configuration H...

Страница 14: ...Status P1 Supply voltage 1 P2 Supply voltage 2 2 100 Mbit s ports 3 Connecting the supply voltage 4 Grounding screw M3 5 Product code 6 LED display elements port state Power N C N C P 1 2 3 4 5 P2 Pin Function P1 1 2 3 4 5 Power 4 9 5 10 1 3 2 8 7 6 P1 P2 OS20 001000T5T5TAFUHB x y OCTOPUS OS20 Unmanaged ETHERNET Switch 3 4 5 6 1 2 ...

Страница 15: ...ts Device Status P Supply voltage 2 100 Mbit s ports 3 Connecting the supply voltage 4 Grounding screw M4 5 Product code 6 LED display elements port state Power N C P 1 2 3 4 N C Pin Function P Power 1 2 4 3 P 4 5 1 3 2 9 10 8 7 6 x y OCTOPUS OS20 Unmanaged ETHERNET Switch OS20 001000T5T5TNEUHB 3 4 5 6 1 2 ...

Страница 16: ...PoE output 2 Ports 1 6 100 Mbit s ports Ports 2 3 4 5 7 8 9 10 100 Mbit s PoE ports 3 Connecting the supply voltage 4 Grounding screw M4 5 Product code 6 LED display elements port state Power N C 1 2 3 4 5 P2 Pin Function P1 Power 4 5 1 2 3 P P1 4 5 1 3 2 9 10 8 7 6 PoE PoE P2 FAULT x y OCTOPUS OS24 Unmanaged ETHERNET Switch OS24 081000T5T5TFFUHB P Port 2 5 7 10 3 4 5 6 1 2 ...

Страница 17: ...ut 2 Ports 1 6 100 Mbit s ports Ports 2 3 4 5 7 8 9 10 100 Mbit s PoE ports 3 Connecting the supply voltage 4 Grounding screw M4 5 Product code 6 LED display elements port state Power N C P 1 2 3 4 N C Pin Function P Power 1 2 4 3 4 5 1 3 2 9 10 8 7 6 PoE PoE FAULT P x y OCTOPUS OS24 Unmanaged ETHERNET Switch OS24 081000T5T5TNEUHB P Port 2 5 7 10 3 4 5 6 1 2 ...

Страница 18: ... Devices featuring supply voltage with the characteristic value N on page 24 1 5 Ethernet ports You can connect end devices and other segments to the device ports using twisted pair cables or optical fibers F O You find information on pin assigments for making patch cables here Pin assignments on page 20 1 5 1 10 100 Mbit s twisted pair port This port is designed as an 4 pin M12 socket The 10 100 ...

Страница 19: ...air cable The devices are supplied with PoE voltage 53 V DC safety low voltage via the internal voltage supply The PoE voltage to the twisted pair cables is supplied via the wire pairs transmitting the signal phantom voltage The total PoE power output is limited to 61 6 W Pin Function 1 TD Transmission path 2 RD Receive path 3 TD Transmission path 4 RD Receive path Housing shield Table 3 Pin assig...

Страница 20: ...in X coded Pin 10 100 Mbit s 1000 Mbit s PoE 1 RX BI_DB Negative VPSE 2 RX BI_DB Negative VPSE 3 TX BI_DA Positive VPSE 4 TX BI_DA Positive VPSE 5 BI_DC 6 BI_DC 7 BI_DD 8 BI_DD LED Display Color Activity Meaning P P1 Supply voltage 1 Green Lights up Supply voltage is on None Supply voltage is too low P2 Supply voltage 2 Green Lights up Supply voltage is on None Supply voltage is too low FAULT Tota...

Страница 21: ... Meaning 1 10 Link status None Device detects an invalid or missing link Green Lights up Device detects a valid link Yellow Flashing Device is transmitting and or receiving data PoE PoE status Green None No powered device connected Lights up Powered device is supplied with power Flashes 1 time a period No power supply to the powered device as the total PoE output of the device has been exceeded ...

Страница 22: ...kage contents Check whether the package includes all items named in the section Scope of delivery on page 35 Check the individual parts for transport damage 2 2 Connecting the connector for the supply voltage Note Only connect the device to a power supply that complies to surge voltage category II or lower 2 2 1 Devices featuring supply voltage with the characteristic value A WARNING ELECTRIC SHOC...

Страница 23: ...r supply cables 2 2 2 Devices featuring supply voltage with the characteristic value F Type and specification of the supply voltage Rated voltage range DC 24 V 48 V Voltage range DC incl maximum tolerances 9 6 V 60 V Figure Pin Function 1 24 48 V DC 1 2 Not used 3 0 V 4 24 48 V DC 2 5 Not used Table 5 Pin assignment of the 5 pin M12 socket for connecting the supply voltage WARNING ELECTRIC SHOCK T...

Страница 24: ...cteristic value N The input voltage is electrically isolated from the housing The supply voltage is connected via a 4 pin 7 8 connector See Accessories on page 36 Use a power supply cable which is suitable for the voltage the current and the physical load Hirschmann recommends a wire diameter of 0 75 mm AWG18 Type and specification of the supply voltage Rated voltage range DC 24 V 48 V Voltage ran...

Страница 25: ...nical forces Failure to follow these instructions can result in death serious injury or equipment damage WARNING RISK OF BURNING Applies to devices featuring supply voltage with the characteristic value N Only install the device in operating sites with restricted access based on EN 60950 1 Applies to devices featuring supply voltage with the characteristic value A and F At ambient temperatures 45 ...

Страница 26: ...temperature to a maximum of 149 F 65 C You install the device on a 1 62 ft2 0 15 m2 metal plate to which you will connect no other heat sources Prepare the drill holes at the installation point Mount the device on a level surface with four M5 screws 2 3 1 Grounding the device The device is grounded via the separate ground screw See Device view on page 14 The overall shield of a connected shielded ...

Страница 27: ...e key supplied 2 5 Connecting the supply voltage Use a back up fuse suitable for the supply network See General technical data on page 31 Do not use connectors as electrical isolating devices Make sure that the disconnecting device is easily accessible for disconnecting the device from the mains voltage Connect the power supply connector to the power supply socket of the device 2 6 Operating the d...

Страница 28: ...data cables do not run parallel over longer distances and that ideally they are installed in separate cable channels If reducing the inductive coupling is necessary verify that the power supply cables and data cables cross at a 90 angle Use shielded cables SF UTP cables as per ISO IEC 11801 2002 Use a shielded CAT5 cable or better Use a shielded 4 pin M12 plug Connect only PoE supplier devices who...

Страница 29: ...ical data is a guideline that indicates to you that the maximum ambient air temperature has possibly been exceeded Therefore the temperature value displayed in the CLI and the GUI differs from the ambient air temperature To determine the actual permitted maximum value for operating the device you perform a reference measurement Install the device at the planned location Switch the device on and wa...

Страница 30: ... of the switching operations Check the resistance of the closed relay contacts and the switching function depending on the frequency of the switching operations Hirschmann is continually working on improving and developing their software Check regularly whether there is an updated version of the software that provides you with additional benefits You find information and software downloads on the ...

Страница 31: ...e range DC incl maximum tolerances 9 6 V 60 V Connection type M12 connector 5 pin Power loss buffer 10 ms Overload current protection at input Non replaceable fuse Back up fuse Nominal rating Characteristic 2 A slow blow Peak inrush current 14 A Power supply Type F Redundant power supply Rated voltage range DC 24 V 48 V Observe the warning for railway standard EN 50155 See Devices featuring supply...

Страница 32: ...age connections and housing Supply voltage Type A 707 V DC Type F 707 V DC Type N 1414 V DC Climatic conditions during operation Ambient temperature 40 F 158 F 40 C 70 C a Humidity 10 95 condensing Air pressure minimum 795 hPa 9842 ft 2000 m maximum 1060 hPa 1312 ft 400 m Climatic conditions during storage Ambient temperature 40 F 185 F 40 C 85 C Humidity 10 95 condensing Air pressure minimum 700 ...

Страница 33: ...etic field 80 MHz 2700 MHz 20 V m IEC EN 61000 4 4 Fast transients burst AC DC supply connection Data line 2 kV 4 kV IEC EN 61000 4 5 Voltage surges DC supply connection Data line line line line ground 1 kV 2 kV 1 kV IEC EN 61000 4 6 Conducted disturbances 150 kHz 80 MHz 10 V EN 61000 4 9 Pulse magnetic fields 300 A m EMC interference emission EN 55022 Class A Yes 52 8 mm 2 08 inch 171 8 mm 6 77 i...

Страница 34: ...e of Type Tests Part 1 Yes IEC 870 2 2 table 3 normal installation according to EN 61850 3 Yes EN 61373 Category 1 Class A broadband noise installation in acc with EN 50155 Yes Shock IEC 60068 2 27 Test Ea test level according to IEC 61131 2 Yes IEC 870 2 2 table 3 normal installation according to EN 61850 3 Yes EN 61373 Category 1 Class A broadband noise installation in acc with EN 50155 Yes 10 1...

Страница 35: ...upply voltage Note Connector ELWIKA 5012 PG7 933 175 100 supports a temperature range from 25 C to 70 C Thus it can restrict the operation location for the overall system You can obtain special connectors with protection class IP54 and an extended temperature range on request Installation user manual OS24 081000T5T5TFFUHB Octopus device Ferrite with key Installation user manual OS20 001000T5T5TNEU...

Страница 36: ...e not suitable for use within an IP54 area Transition M12 D coded to RJ45 Name Order number Connector ELWIKA 5012 PG7 5 pin M12 socket for voltage supply 933 175 100 Field attachable 5 pin M12 socket A coded with 2 cable outputs RKC5 Duo M12 connector 4 pin D coded 934 445 001 7 8 connectors 4 pin 942 086 004 7 8 connectors 5 pin 942 086 005 Connection cable with M12 connector D coded 934 497 00x ...

Страница 37: ...munity for signal and telecommunication systems EN 50155 Railway applications Electronic equipment used on rolling stock EN 55022 Information technology equipment Radio disturbance characteristics Limits and methods of measurement EN 61000 6 2 Electromagnetic compatibility EMC Part 6 2 Generic standards Immunity for industrial environments EN 61131 2 Programmable controllers Part 2 Equipment requi...

Страница 38: ... 6854 9860 E mail inet ap belden com Hirschmann Competence Center The Hirschmann Competence Center is ahead of its competitors Consulting incorporates comprehensive technical advice from system evaluation through network planning to project planning Training offers you an introduction to the basics product briefing and user training with certification The current technology and product training co...

Страница 39: ...Installation OCTOPUS OS20 OS24 Unmanaged Release 08 07 2015 39 ...

Страница 40: ......