![Hirschmann MACH 4000 Series Скачать руководство пользователя страница 174](http://html1.mh-extra.com/html/hirschmann/mach-4000-series/mach-4000-series_user-manual_2138020174.webp)
Operation Diagnostics
174
9.3 Out-of-band signaling
Basic - L3P
Release 3.1 06/07
9.3 Out-of-band signaling
The signal contacts are for
D
controlling external devices by manually setting the signal contacts.
D
monitoring proper functioning of the Switch which makes it possible to
perform remote diagnostics.
A break in contact is reported via the potential-free signal contact
(relay contact, closed circuit):
D
Faulty power supply:
the failure of the supply voltage 1/2,
a continuous malfunction in the Switch (internal supply voltage).
D
Values that exceed or fall below the set temperature threshold.
D
Removing a module.
D
Removing the ACA.
D
The defective link status of at least one port. With the Switch, the indica-
tion of link status can be masked by the management for each port (see
“Displaying connection error messages” on page 70
). Link status is not
monitored in the delivery condition.
D
HIPER-Ring event:
the loss of redundancy guarantee (in Redundancy Manager mode). Ring
redundancy is not monitored in the delivery condition.
D
Redundant Ring/Netcoupling event:
the loss of redundancy guarantee. Ring redundancy is not monitored in
the delivery condition.
In Stand-by mode the Switch reports additionally the following conditions:
– the faulty link status of the control line
– partner device is in stand-by mode
It depends on the management setting which events cause a contact to
switch.
Note:
With non-redundant supply of the mains voltage, the Switch reports a
power failure. You can prevent this message by applying the supply voltage
over the two inputs or by switching off the monitoring
“Monitoring correct operation via the signal contact” on page 176
Содержание MACH 4000 Series
Страница 8: ...Contents 8 Basic L3P Release 3 1 06 07 Appendix C Index 231...
Страница 12: ...Key 12 Basic L3P Release 3 1 06 07 Hub A random computer Configuration computer Server...
Страница 14: ...Introduction 14 Basic L3P Release 3 1 06 07...
Страница 50: ...Entering the IP parameters 50 2 9 Faulty Device Replacement Basic L3P Release 3 1 06 07...
Страница 60: ...Loading saving settings 60 3 2 Saving settings Basic L3P Release 3 1 06 07...
Страница 72: ...Configuring ports 72 Basic L3P Release 3 1 06 07 Fig 20 Power over Ethernet dialog...
Страница 102: ...Protection from unauthorized access 102 6 6 Access Control Lists ACL Basic L3P Release 3 1 06 07...
Страница 120: ...Synchronizing the System Time of the 120 7 4 Interaction PTP and SNTP Basic L3P Release 3 1 06 07...
Страница 132: ...Traffic control 132 8 2 Multicast application Basic L3P Release 3 1 06 07 Fig 35 IGMP dialog...
Страница 160: ...Traffic control 160 8 6 VLANs Basic L3P Release 3 1 06 07 Fig 46 Assigning a VLAN any name and saving it...
Страница 162: ...Traffic control 162 8 6 VLANs Basic L3P Release 3 1 06 07 Fig 48 Saving the VLAN configuration...
Страница 179: ...Operation Diagnostics Basic L3P Release 3 1 06 07 9 4 Port status indication 179 The port is in autonegotiation mode...
Страница 181: ...Operation Diagnostics Basic L3P Release 3 1 06 07 9 5 Event counter on port level 181 Fig 56 Port statistic table...
Страница 195: ...Setting up the configuration Basic L3P Release 3 1 06 07 195 Apendix A Setting up the configuration environment...
Страница 217: ...General Information Basic L3P Release 3 1 06 07 217 Appendix B General Information...
Страница 234: ...Index 234 Basic L3P Release 3 1 06 07...
Страница 235: ......
Страница 236: ......