Installation EAGLE20/30
Release 12 03/2021
47
7
Technical data
General technical data
Weight
EAGLE..-.........999S..
approx. 2.65 lb (1.2 kg)
EAGLE..-.........999T..
EAGLE..-.........999E..
EAGLE..-.........9H2S..
approx. 3.31 lb (1.5 kg)
EAGLE..-.........9H2E..
EAGLE..-.........9H2T..
approx. 4.19 lb (1.9 kg)
Power supply
Supply voltage
with the
characteristic
value CC
See “Requirements for connecting electrical wires” on page 9.
Nominal voltage DC
24 V DC ... 48 V DC
Voltage range DC incl.
maximum tolerances
18 V DC ... 60 V DC
Voltage range DC in
Hazardous Locations (Class I,
Division 2) incl. maximum
tolerances
22 V DC ... 52 V DC
Connection type
2-pin terminal block
Power loss buffer
>10 ms at 20.4 V DC
Overload current protection on
the device
Non-replaceable fuse
Back-up fuse
Nominal rating:
Characteristic:
6.3 A
slow blow
Peak inrush current
<4 A
Power supply
Supply voltage
with the
characteristic
value K9
and KK
See “Requirements for connecting electrical wires” on page 9.
Nominal voltage AC
110 V AC ... 230 V AC, 50 Hz ... 60 Hz
Voltage range AC incl.
maximum tolerances
88 V AC ... 265 V AC, 47 Hz ... 63 Hz
Voltage range AC in
Hazardous Locations (Class I,
Division 2) incl. maximum
tolerances
99 V AC ... 253 V AC
Nominal voltage DC
60 V DC ... 250 V DC
Voltage range DC incl.
maximum tolerances
48 V DC ... 320 V DC
Voltage range DC in
Hazardous Locations (Class I,
Division 2) incl. maximum
tolerances
54 V DC ... 275 V DC
Connection type
3-pin terminal block
Power loss buffer
>10 ms at 98 V AC
Overload current protection on
the device
Non-replaceable fuse
Back-up fuse
Nominal rating:
Characteristic:
min. 2.5 A
max. 20 A
slow blow
Peak inrush current
<3.5 A
Содержание HiSecOS EAGLE20