Diagnostics
[ Diagnostics > Status Configuration > Signal Contact > Signal Contact 1 ]
246
RM GUI GRS
Release
8.0
09/2019
Possible values:
open
The signal contact is opened.
close
The signal contact is closed.
Signal contact status
Signal contact status
Displays the current status of the signal contact.
Possible values:
Opened (error)
The signal contact is opened. The circuit is interrupted.
Closed (ok)
The signal contact is closed. The circuit is closed.
Trap configuration
Send trap
Activates/deactivates the sending of SNMP traps when the device detects changes in the
monitored functions.
Possible values:
marked
The sending of SNMP traps is active.
If the device detects a change in the monitored functions, then the device sends an SNMP trap.
unmarked
(default setting)
The sending of SNMP traps is inactive.
The prerequisite for sending SNMP traps is that you enable the function in the
Diagnostics > Status
Configuration > Alarms (Traps)
dialog and specify at least 1 trap destination.
Monitoring correct operation
In the table you specify the parameters that the device monitors. The device signals the occurrence
of an event by opening the signal contact.
Temperature
Activates/deactivates the monitoring of the temperature in the device.
Содержание GREYHOUND GRS1020
Страница 8: ......
Страница 16: ......
Страница 146: ......
Страница 232: ......
Страница 310: ......
Страница 330: ......
Страница 338: ...Readers Comments 337 RM GUI GRS Release 8 0 09 2019 ...
Страница 339: ......
Страница 340: ......
Страница 350: ......
Страница 354: ......
Страница 617: ...Readers Comments 277 UM Config GRS Release 8 0 09 2019 ...
Страница 618: ......
Страница 619: ......