Link Backup
[ Switching > L2-Redundancy > Link Backup ]
With Link Backup, you configure pairs of redundant links. Each pair has a primary port and a
backup port. The primary port forwards traffic until the device detects an error. If the device detects
an error on the primary port, then the Link Backup function transfers traffic over to the backup port.
The dialog also lets you set a fail back option. If you enable the fail back function and the primary
port returns to normal operation, then the device first blocks traffic on the backup port and then
forwards traffic on the primary port. This process helps protect the device from causing loops in the
network.
Operation
Operation
Enables/disables the Link Backup function globally in the device.
Possible values:
On
Enables the Link Backup function.
Off
(default setting)
Disables the Link Backup function.
Table
Primary port
Displays the primary port of the interface pair. When you enable the Link Backup function, this port
is responsible for forwarding traffic.
Possible values:
Physical ports
Backup port
Displays the backup port on which the device forwards traffic if the device detects an error on the
primary port.
Possible values:
Physical ports except for the port you set as the primary port.
Description
Specifies the Link Backup pair. Enter a name to identify the Backup pair.
Possible values:
Alphanumeric ASCII character string with 0..255 characters
Содержание GREYHOUND GRS1020
Страница 8: ......
Страница 16: ......
Страница 146: ......
Страница 232: ......
Страница 310: ......
Страница 330: ......
Страница 338: ...Readers Comments 337 RM GUI GRS Release 8 0 09 2019 ...
Страница 339: ......
Страница 340: ......
Страница 350: ......
Страница 354: ......
Страница 617: ...Readers Comments 277 UM Config GRS Release 8 0 09 2019 ...
Страница 618: ......
Страница 619: ......