52
Installation BAT-R
Release 09 03/2017
7
Technical data
7.1
General technical data
Weight
Device variants featuring supply voltage with
characteristic value P
approx. 42.33 oz
(1200 g)
Device variants featuring supply voltage with
characteristic value C or K
approx. 52.91 oz
(1500 g)
Device variants featuring supply voltage with
characteristic value W
and approvals 1 with characteristic value F, G, I,
M or 9
approx. 42.33 oz
(1200 g)
Device variants featuring supply voltage with
characteristic value W
and approvals 1 with characteristic value K
approx. 45.86 oz
(1300 g)
Supply voltage
with the
characteristic
value C
Class 2
Rated voltage range DC
24 V ... 48 V
Voltage range DC incl.
maximum tolerances
18 V ... 60 V
Connection type
2-pin terminal block
Power loss buffer
> 10 ms at 20.4 V DC
Overload current protection at
input
Non-replaceable fuse
Back-up fuse for each voltage
input when supply is via 2
inputs
Nominal rating:
Characteristic:
Max. 1.5 A
slow blow
Back-up fuse when using 1
voltage input
a
Nominal rating:
Characteristic:
Max. 3.15 A
slow blow
Back-up fuse when installed in
a fire-protection shell
according to EN 60950-1
Nominal rating:
Characteristic:
Max. 6.3 A
slow blow
Peak inrush current
14 A
Supply voltage
with the
characteristic
value K
Rated voltage range AC
110 V ... 230 V, 50 Hz ... 60 Hz
Voltage range AC incl.
maximum tolerances
88 V ... 265 V, 47 Hz ... 63 Hz
Rated voltage range DC
60 V ... 250 V
Voltage range DC incl.
maximum tolerances
48 V ... 320 V
Connection type
3-pin terminal block
Power loss buffer
> 10 ms at 98 V AC
Overload current protection at
input
Non-replaceable fuse
Back-up fuse for each voltage
input
Nominal rating:
Characteristic:
2.5 A
slow blow
Peak inrush current
14 A