HIROSE ELECTRIC CO.,LTD.

 

ETAD-T0685-01

 

6

 /

 

FORM HC0011-9-2 

 

 
Crimp quality standard 
 

① 

Position of crimping 

 

A※1 

0.1 MIN 

B※2 

0.35 MAX 

C 

1.0-2.0 

D 

0.3-1.0 

1 There is no problem in quality if the wire can be verified at the edge of the wire barrel.

2 In case of inspecting by appearance, verify that the cable dielectric exceeds b1. 

 
 
 
 

 

 
 
 
 
 

② 

Bendinig up, bending down 

 

E  -10°MAX 

-5°MAX 

10°MAX 

5°MAX 

 
 
 
 

③ 

Rolling 

 
 

±5°MAX 

±5°MAX 

 
 
 
 
 
 
 
 

 

 

b1 

Jan.1.2022 Copyright 2022 HIROSE ELECTRIC CO., LTD. All Rights Reserved.

Содержание GT21B

Страница 1: ...1B Terminal Instruction Manual APPROVED KI HIROKAWA 20210701 CHECKED MH YAMAGUCHI 20210701 DESIGNED HK WATANABE 20210701 WRITTEN HK WATANABE 20210701 TECHICAL SPECIFICATION ETAD T0685 01 0 1 8 FORM HC...

Страница 2: ...onfiguration GT21B 2426 1 6 2 9SCF Female terminal GT21B 2426 1 6 2 9PCF Male terminal Shield barrel Insulation Barrel Insulation Barrel Shield barrel Wire barrel Carrier Wire barrel Carrier Jan 1 202...

Страница 3: ...ow Cable cut dimensions GT21B 2426 1 6 2 9SCF S type housing GT21T 1S HU GT21 1S HU Cable cut dimensions GT21B 2426 1 6 2 9PCF P type housing GT21N 1PP HU Note The dimensions of the stripping specific...

Страница 4: ...the terminal plate Picture1 In case of interference the terminal cannot be set up correctly Verify the crimping data of the appropriate cable and measure the C H as shown on the cross section below Wh...

Страница 5: ...he product s function GT21B 2426 1 6 2 9PCF Appearance after crimping GT21B 2426 1 6 2 9SCF Appearance after crimping Picture2 Appropriate appearance after crimping The shield braid may be trapped bet...

Страница 6: ...0 1 There is no problem in quality if the wire can be verified at the edge of the wire barrel 2 In case of inspecting by appearance verify that the cable dielectric exceeds b1 Bendinig up bending down...

Страница 7: ...LTD ETAD T0685 01 0 7 8 FORM HC0011 9 2 Twisting 5 MAX 5 MAX Cutoff tab 0 3MAX Crimp burr height 1 0 05MAX 2 0 15MAX 3 0 05MAX Bell mouth P 0 1 0 4 Jan 1 2022 Copyright 2022 HIROSE ELECTRIC CO LTD Al...

Страница 8: ...not to deform terminals when touching them Do not store terminals in a dusty place Do not apply intense shocks to terminals Do not put wire harnesses on the floor Connectors are easily affected by sh...

Отзывы: