![HIQUEL SLS-500 Master Controller Скачать руководство пользователя страница 67](http://html1.mh-extra.com/html/hiquel/sls-500-master-controller/sls-500-master-controller_software-manual_2137777067.webp)
HIQUEL
HIQUEL
HIQUEL
HIQUEL
SLS-500-Configurator
www.hiquel.com
67
The digital output L1.DO1 is active as soon as one of the two
digital inputs L1.DI1 and L1.DI2 are active. If both are active
the digital output will be active too.
Binary operator: Binary EXCLUSIVE OR
Symbol:
^
^
Data type: In1,In2
Bit
Out
Bit
Function:
This function calculates the EXCLUSIVE OR-connection by
using two input signals and delivers the result to the output.
In1 In2 Out
0 0 0
0 1 1
1 0 1
1 1 0
Example:
^
^
L1.DI1
L1.DI1
L1.DI2
L1.DI2
L1.DO1
L1.DO1
Digital output L1.DO1 is active, as long as one of the two
digital inputs L1.DI1 and L1.DI2 is active. If both are
simultaneously active, the digital output will not be active.