Function:
This flag is not available on every SLS-500 Master-Controller.
The flag has the value 1 for one program cycle at intervals of
1mS. Otherwise the flag is always 0. Use this flag for example
with signal time measuring.
Special flag: every 10ms
Symbol:
10ms
10ms
Data type: Bit
Function:
The flag has the value 1 for one program cycle at intervals of
10mS. Otherwise the flag is always 0. Use this flag for
example with signal time measuring
Special flag: every 100ms
Symbol:
100ms
100ms
Data type: Bit
Function:
The flag has the value 1 for one program cycle at intervals of
100mS. Otherwise the flag is always 0. Use this flag for
example with signal time measuring.
Special flag: Clock every second
Symbol:
Second
Second
Data type: Bit
Function:
an integrated real time clock creates this flag. The flag returns
the value 1 every second for exactly one cycle, otherwise it is
0. Use this flag for a flasher signal for example