SLS-500-Configurator
www.hiquel.com
190
Button: Download
Choose this button the program which was compiled will be
loaded to the connected SLS500. There the program will be
started immediately.
Read/write binary memory
You can read Bits from the current program and set new bits
with the PLC Manager. Use the right area of the PLC Manager.
Choose
Name
to enter the name of the bit – the name
corresponds to the names of the memory, which were set in
SLS-500-Configurator – or to set a memory number. Do this by
prefixing a # character before the number (for example #123).
Type must be Bit.
Click the button
Get
to query the current state of the Bit.
You can also set a new value by choosing Value (0 or 1) and
pressing
Set
.
Read/write analogue memory
Reading the analogue values is done in the same way as
reading binary values. You just have to change the Type to
Analogue. To preset an analogue value enter a valid value into
the field
Value
.
Read/write text memory
To read and write text memories you just have to change the
Type to Text and enter a character string into the field
Value
.