Страница 2: ...rque meters are used by manufacturers of electronic goods cameras watches and other kinds of precision instruments as well as by makers of automobiles and aircraft Applications Torque measurement of power screwdrivers torque drivers and torque wrenches Certification of performance of torque tools Torque measurement of other kinds of rotation tools may require adapter Examples of uses of torque mea...
Страница 3: ... of the battery charger See page 10 for instructions on battery charging Use only the products specified in these operat ing instructions for connection to the data output ports When disconnecting cables grasp the cable plug and take care not to damage connector pins Always turn the power switch off after complet ing measurement operations Do not strike the acrylic display panel or place heavy obj...
Страница 4: ... TRACK Displays current torque value F PEAK Freezes display at first peak torque value AC connector For battery charger Analog data output Port for analog voltage data output ANALOG OUT Digital data output Press reset to output measurement data This functions makes it possible to use the DATA OUT instrument in statistical process control systems DIP switch For setting auto reset timer and turning ...
Страница 5: ...e Upper 6 35 mm subtense Lower Driver Shaft Part No TF6XG 0010 Part No TF5G 0010 4 Hex shank convertible shaft 5 mm subtense Upper 6 35 mm subtense Lower 1 pc 1 pc Supplied Accessories Fidaptor with Safety Guard Market Areas Hios shank 4 Measuring range 0 15 0 6N m Yellow Spring Part No TF4G Z 1 pc Measuring range 0 15 6N m Yellow Spring Part No TF6SG Z 1 pc Hios shank 4 Part No TF G3 1 pc Exclusi...
Страница 6: ...DIP switch page 6 to the on position so the P ON LED lights set the MODE switch to PEAK and press the RESET switch which functions the same as the Enter key on a computer The Input Tool will convert the measurement data for direct in put to a spreadsheet application In order to out put data please conduct measurement within the instrument s peak measurement range as indi cated in the specification...
Страница 7: ...d is reached This tone also sounds when the torque set ON ON Reset Setting Warning tone Track Peak Switch functions for setting torque Switches used SET switch 1 Press for 2 seconds to enter torque setting mode Press for 2 seconds once again to exit torque set ting mode 2 When the meter is in torque setting mode the 4 digit display can be adjusted one digit at a time Use the SET switch to select t...
Страница 8: ...2 0003 0004 0001 0002 0003 0004 Fig 4 Full deletion of measurement data Partial deletion of measurement results Example of full deletion of measurement data Memory function on LED on measurement data in memory Ready for measurement M_CR switch M_CR switch Full data deletion mode display Press for 2 seconds Display flickers Exit full deletion mode RESET pressed or no action for 30 seconds Press onc...
Страница 9: ...lay of average measurement data Data is displayed while in average measurement mode and is deleted when the mode is terminated Each time the AVE switch is pressed minimum average and maxi mum values are displayed flickering Fig 1 Min Ave 1st measurement deleted 11th measurement recorded 0001 0002 0003 0010 0001 0002 0003 0009 0010 0001 0002 0003 0009 0010 Notes 1 Be sure to set MODE switch to PEAK...
Страница 10: ...9 6 See that each measuring cycle lasts 5 seconds or more to minimize wearing of parts 7 Never attach the Fidaptor unless you intend to use it immediately When it is not in use always remove it from the torque tool and remove the tension from the spring 8 Always be sure that the Fidaptor is properly at tached to the torsion tool 9 Do not use the Fidaptor if it has been bent or in some way modified...
Страница 11: ...this instrument Do not place objects on top of the battery charger s cord Do not subject the cord to extreme bending or tie it in knots Be sure the power to the instrument is off when attaching or detaching the battery charger Do not attempt to remove the battery from the instrument Cautions in making a socket adapter Make sure that the adapter fits snugly into the socket Make sure the adapter is ...
Страница 12: ...t questions about customer services to Hios Corporation or your Hios dealer Attention The product that you have purchased contains a re chargeable battery The battery is recyclable At the end of it s useful life under various state and local laws it may be illegal to dispose of this bat tery into the municipal waste stream Check with your local solid waste officials for details in your area for re...
Страница 13: ...re is a display If there is not contact Hios or your Hios dealer Conduct zero adjustment Set to PEAK Check that the plug is connected properly Connect to the battery charger socket If the above does not remedy the problem contact Hios or your Hios dealer Send to Hios for repair Recharge the battery for no more than 6 hours Press RESET switch to clear the display Insufficient battery charge This ma...
Страница 14: ...ata output from the torque meter Sign Entry number Data type Decimal point position Measured value Unit mm Both Model HP 100 and HP 10 have the same dimensions Note that specifications or the external ap pearance of Hios torque meters are subject to change without notice External features diagram Max BZ Ave Min P ON SET Digital Torque Meter AVE M_CR M_SET PEAK TRAK POWER ON MODE UNIT RESET F PEAK ...
Страница 15: ...111 6 Akiyama Matsudo City Chiba Pref Japan TEL 81 Japan 47 392 2001 FAX 81 Japan 47 392 7773 ...