![Hioki RM3542-50 Скачать руководство пользователя страница 158](http://html1.mh-extra.com/html/hioki/rm3542-50/rm3542-50_instruction-manual_2137361158.webp)
9.7 Message Reference
152
(7) Trigger
Relationship Between Trigger Source and Continuous Measurement Operation
Operates as follows with the continuous Measurement setting (
:INITIATE:CONTINUOUS
) (p. 153) and trigger
source setting (
:TRIGGER:SOURCE
See:
"9.8 Data exporting methods" (p. 163)
Measurement
flow
Continuous Measurement Command setting only
:INITIATE:CONTINUOUS ON
:INITIATE:CONTINUOUS OFF
Trigger Source
:TRIGGER:SOURCE IMM
Free-Run state. Measurement continues au-
tomatically.
Trigger by
:INITIATE
(or
:READ?
)
command.
:TRIGGER:SOURCE EXT
Trigger by the TRIG signal, F4 [MANU], or
∗
TRG
command.
After measurement, enters the trigger wait
state.
Waits for trigger with
:INITIATE
(or
:READ?
).
Trigger by TRIG signal.
:INITIATE:CONTINUOUS OFF
It can only be set by the Remote command.
If this has been set to OFF and the operation returns to the Local state or power is turned on again, the following state will
be set when the power is turned back on.
:INITIATE:CONTINUOUS ON
("To Cancel the Remote Status (Enter the Local Status)" (p. 116))
How to export measurement values:"9.8 Data exporting methods" (p. 163)
Measurement
Calculation
Measurement Value Output
Trigger Delay
Idle State
Measurement
Calculation
Measurement Value Output
Trigger Delay
:INITIATE:IMMEDIATE
or
:READ?
Trigger Wait State
Measurement
Calculation
Measurement Value Output
Trigger Delay
By either the TRIGsignal,
F4 [MANU] or
∗
TRG.
Trigger Wait State
Measurement
Calculation
Measurement Value Output
Trigger Delay
Idle State
TRIG signal
:INITIATE:IMMEDIATE
or
:READ?
Содержание RM3542-50
Страница 1: ......
Страница 2: ......
Страница 6: ...Table of Contents iv...
Страница 26: ...1 3 Screen Organization 20...
Страница 32: ...2 3 Turning the Power On and Off 26...
Страница 48: ...3 8 Confirming Faulty Measurements 42...
Страница 72: ...4 14 Compensating for Thermal EMF Offset Offset Voltage Compensation OVC 66...
Страница 84: ...5 7 Initializing Reset 78...
Страница 94: ...6 4 Auto Exporting Measurement Values at End of Measurement Data Output Function 88...
Страница 206: ...11 4 Disposing of the Instrument 200...
Страница 216: ...Appendix 5 Dimensional diagram A10 Appendix 5 Dimensional diagram Unit mm...
Страница 230: ...Index Index 4...
Страница 231: ...HIOKI E E CORPORATION...
Страница 232: ......
Страница 233: ......
Страница 234: ......