PW3390 Power Analyzer Communication Command Instruction Manual Second Edition
33/107
Select and Query Harmonic List Saved Items
Syntax
Command
:DATAout:ITEM:HARMonic:LIST <Level UI>,<Level P>,
<Content UI>,<ContentP>,<Phase Angle UI>,<Phase Angle P>
Query
:DATAout:ITEM:HARMonic:LIST?
Response
<Level UI>,<LevelP>,<Content UI>,<Content P>,<Phase Angle UI>,
<Phase Angle P>
128
64
32
16
8
4
2
1
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
Level UI
HI4
HI3
HI2
HI1
HU4
HU3
HU2
HU1
Level P
FREQ
HP123
HP34
HP12
HP4
HP3
HP2
HP1
Content UI
HI4
HI3
HI2
HI1
HU4
HU3
HU2
HU1
Content P
-
HP123
HP34
HP12
HP4
HP3
HP2
HP1
Phase Angle UI
HI4
HI3
HI2
HI1
HU4
HU3
HU2
HU1
Phase Angle P
-
HP123
HP34
HP12
HP4
HP3
HP2
HP1
Description
Command
Sets the harmonic saved items between 0 and 255.
Here, specify the harmonic list (level, content, phase angle).
To set the items, use the ON/OFF of the bits above, and specify a numerical
value between 0 and 255.
Query
Returns the harmonic list setting of the harmonic saved items with values of
0
– 255.
Example
Command
:DATA:ITEM:HARM:LIST 1,1,1,1,1,1
Set U1, P1 level, content and phase angle as the harmonic saved item list.
Query
:DATA:ITEM:HARM:LIST?
Response
:DATAOUT:ITEM:HARMONIC:LIST 1,1,1,1,1,1 (WHEN HEADER IS ON)
1,1,1,1,1,1 (WHEN HEADER IS OFF)
Note
For the order of saving, set it with the ":DATAout:ITEM:HARMonic:ORDer"Command.
When an unselectable item is specified, an execution error will occur and other items will also
not be set.
Содержание PW3390