![Hioki PW3336-01 Скачать руководство пользователя страница 136](http://html1.mh-extra.com/html/hioki/pw3336-01/pw3336-01_instruction-manual_2137351136.webp)
4.3 Operating the Instrument from a PC's Browser
130
Operating the instrument remotely
Selecting [
Remote
] on the menu displays the Remote Operation screen. The screen shown on the instrument
will be shown as-is in the browser window.
The buttons on the control panel correspond go the buttons on the instrument. You can also operate the
instrument remotely by clicking the screen with the mouse (the same key operation as the instrument).
You can save a PNG-format screenshot by clicking the [
Screen copy
] button.
You can also zoom in and out on most browsers by using CTRL + “+” to zoom in, CTRL + “-” to zoom out, and
CTRL + “0” to select normal size.
Instrument keys + shift key
You can place the instrument in the shift state by holding down the computer’s shift key while you click on keys on the
screen with your mouse.
Example: Auto-range settings (voltage range)
You can set auto-range operation by clicking the
voltage range while holding down the computer’s shift key.
Changing the rectifier
You can change the displayed rectifi-
er by clicking on the rectifier part (
DC
,
AC
,
FND
,
Umn
) of the measured val-
ue display area.You can also select
ACDC
by holding down the comput-
er’s shift key while you click the recti-
fier part of the display.
You can select how often
the screen is updated (up-
date speeds are about 0.3
sec [High], 1 sec [
Normal
],
and 10 sec [
Low
]).
You can display a com-
ment at the top right of the
Save screen by entering
it in this field. Supported
with Internet Explorer ver.
9 and later.
Changing display channels
You can change display channels by
clicking the
CH1
to
CH3
part of the
measured value display area.
Changing display parameters
You can change display parameters by clicking on the
display parameters (
V
,
A
,
W
,
VA
,
etc
.) in the measured
value display area. You can select
pK
,
Hz
,
THD
,
θ
,
T
.
AV
,
RF
, and
CF
by using the computer’s
shift
key.
Example: To display the current or voltage peak value
Click
pk
while holding down the computer’s
shift
key.
→
The current peak value will be displayed.
Click
pk
(do not press the computer’s
shift
key).
→
The voltage peak value will be displayed.
Changing the wiring mode
You can change the wiring mode
by clicking on the wiring mode dis-
play area.
Содержание PW3336-01
Страница 2: ......
Страница 6: ...Contents iv...
Страница 16: ...Operating Precautions 10...
Страница 32: ...1 4 Measurement Workflow 26...
Страница 44: ...2 7 Turning Off the Instrument 38...
Страница 180: ...5 6 Wiring Specifications 174 3 3 phase 3 wire 3P3W 3P3W2M 4 3 phase 3 wire 3V3A 3P3W3M Current sensor...
Страница 181: ...5 6 Wiring Specifications 175 5 3 phase 4 wire 3P4W Current sensor...
Страница 182: ...5 6 Wiring Specifications 176...
Страница 199: ...Appendix 4 Dimensional Diagram A13 e g PW3337 03 Appendix 4 Dimensional Diagram Unit mm...
Страница 200: ...Appendix 4 Dimensional Diagram A14...
Страница 203: ......
Страница 204: ......
Страница 205: ......
Страница 206: ......