104
Saving Data
(When you choose
[Waveform (Binary)]
in the
[Type]
box)
Tap the
[Divide]
box, and then from the list, choose a size of each file.
Off
Saves a file without dividing it.
16 MB
,
32 MB
,
64 MB
Choose this option to divide a large file into several files and save them. A file is
divided into several files each of which has the specified size. The instrument creates
a folder with the specified name, divides a file into several files, and then saves them
in the folder.
Even if the
[Divide]
has been set to
[Off]
, the instrument automatically divides files more than 512 MB in
size, which can be generated in some measurement conditions. When the instrument needs to divide a file, it
automatically creates a folder to save divided files and an index file with the extension .INX. Loading the IDX
file allows the waveform files to be loaded in a batch.
When using the memory division function, you cannot use the division save function.
See “Loads divided files in a batch.” (p. 115) and “10 Memory Division Function” (p. 255).
(When you choose
[Waveform (Text)]
in the
[Type]
box)
Tap the
[Divide]
box, and then from the list, choose an option for the number of lines of each file.
Off
Saves a file without dividing it.
60,000 data
,
1,000,000 Data
Divides a file according to data points (row) you specify.
Even if the
[Divide]
has been set to
[Off]
, the instrument automatically divides files more than 512 MB in size,
which can be generated in some measurement conditions.
When using the memory division function, you cannot use the division save function.
See “10 Memory Division Function” (p. 255).
(When you choose
[Waveform (Text)]
in the
[Type]
box)
Tap the
[Thin out]
button to set it to
[On]
or
[Off]
.
When you choose
[On]
, tap the number box on the right, and then enter the number of samples out of
which a data point is retained
Storing files in text format requires a lot of storage space. Data decimation can reduce file sizes.
Off
No data is decimated.
On
(
2
to
1,000
)
Allows you to enter the decimation number. The instrument retains one data point out
of the specified number of data points.
Example
When you enter
[3]
, the instrument retains one data point out of three consecutive data points:
it decimates the two other points. The number of samples is reduced by one third of the original
number.
7
In the
[Calculation result]
area, tap
[On]
or
[Off]
to configure the numerical calculation result
setting.
Off
Does not any save numerical calculation results.
On
Saves numerical calculation results.
Tap the
[File]
box, and then from the list, choose an option for saving data to files.
New
Creates a new file for each measurement and saves it.
Append
Appends data to an existing file and saves it.
Tap the
[Divide]
box, and then choose a file division setting from the list.
Off
Does not divide any files.
Split by Calc. No.
Creates a file for each calculation number.
HIOKI MR6000A966-03
Содержание Memory HiCorder MR6000
Страница 2: ...HIOKI MR6000A966 03...
Страница 56: ...50 Displaying Measured Values HIOKI MR6000A966 03...
Страница 152: ...146 Triggering the Instrument Using CAN Signals CAN Trigger HIOKI MR6000A966 03...
Страница 194: ...188 Numerical Calculation Types and Descriptions HIOKI MR6000A966 03...
Страница 266: ...260 Configuring the Display Settings HIOKI MR6000A966 03...
Страница 391: ...HIOKI MR6000A966 03...
Страница 392: ...HIOKI MR6000A966 03...